SearcharxivSearch

arXiv subjects

Xinhui Huang

Publications and source records attributed to Xinhui Huang.

8 recordsLinked to original sources

Beam test result and digitization of TaichuPix-3: A Monolithic Active Pixel Sensors for CEPC vertex detector

The Circular Electron-Positron Collider (CEPC), as the next-generation electron-positron collider, is tasked with advancing not only Higgs physics but also the discovery of new physics. Achieving these goals requires high-precision measurements of particles. Taichu seires, Monolithic Active Pixel Sensor (MAPS), a key component of the vertex detector for CEPC was designed to meet the CEPC's requirements. For the geometry of vertex detector is long barrel with no endcap, and current silicon lacks a complete digitization model, precise estimation of cluster size particularly causing by particle with large incident angle is needed. Testbeam results were conducted at the Beijing Synchrotron Radiation Facility (BSRF) to evaluate cluster size dependence on different incident angles and threshold settings. Experimental results confirmed that cluster size increases with incident angle. Simulations using the Allpix$^2$ framework replicated experimental trends at small angles but exhibited discrepancies at large angles, suggesting limitations in linear electric field assumptions and sensor thickness approximations. The results from both testbeam and simulations have provided insights into the performance of the TaichuPix chip at large incident angles, offering a crucial foundation for the establishment of a digital model and addressing the estimation of cluster size in the forward region of the long barrel. Furthermore, it offers valuable references for future iterations of TaichuPix, the development of digital models, and the simulation and estimation of the vertex detector's performance.

physics.ins-det

The Performance of AC-coupled Strip LGAD developed by IHEP

The AC-coupled Strip LGAD (Strip AC-LGAD) is a novel LGAD design that diminishes the density of readout electronics through the use of strip electrodes, enabling the simultaneous measurement of time and spatial information. The Institute of High Energy Physics has designed a long Strip AC-LGAD prototype with a strip electrode length of 5.7 mm and pitches of 150 $μm$, 200 $μm$, and 250 $μm$. Spatial and timing resolutions of the long Strip AC-LGAD are studied by pico-second laser test and beta source tests. The laser test demonstrates that spatial resolution improves as the pitch size decreases, with an optimal resolution achieved at 8.3 $μ$m. Furthermore, the Beta source test yields a timing resolution of 37.6 ps.

physics.ins-det

Development of the strip LGAD detector with double-end readout for future colliders

The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to construct a High Granularity Timing Detector (HGTD) in ATLAS experiments to solve the pile-up problem. Meanwhile, the Circular Electron Positron Collider (CEPC) also proposes detectors using the LGAD. However, pixel LGAD exhibits higher readout electronics density and cost, which somewhat limits the application of LGADs. To decrease the readout electronics density, the Institute of High Energy Physics (IHEP) of the Chinese Academy of Sciences has designed strip LGADs with larger areas. These strip LGADs are all 19 mm in length but with different widths of 1.0 mm, 0.5 mm, and 0.3 mm. This article provides a detailed introduction to the design parameters of these strip LGADs and tests their electrical characteristics, including leakage current, break-down voltage, depletion capacitance, etc. The timing resolution and signal-to-noise ratio of the three strip LGAD sensors were investigated using a beta source test system. The position resolution parallel to the strip direction was tested and analyzed for the first time using a pico-second laser test system. Tests have demonstrated that the timing resolution of strip LGADs can reach about 37.5 ps, and position resolution parallel to the strip direction is better than 1 mm.

physics.ins-det

Beam test of a baseline vertex detector prototype for CEPC

The Circular Electron Positron Collider (CEPC) has been proposed to enable more thorough and precise measurements of the properties of Higgs, W, and Z bosons, as well as to search for new physics. In response to the stringent performance requirements of the vertex detector for the CEPC, a baseline vertex detector prototype was tested and characterized for the first time using a 6 GeV electron beam at DESY II Test Beam Line 21. The baseline vertex detector prototype is designed with a cylindrical barrel structure that contains six double-sided detector modules (ladders). Each side of the ladder includes TaichuPix-3 sensors based on Monolithic Active Pixel Sensor (MAPS) technology, a flexible printed circuit, and a carbon fiber support structure. Additionally, the readout electronics and the Data Acquisition system were also examined during this beam test. The performance of the prototype was evaluated using an electron beam that passed through six ladders in a perpendicular direction. The offline data analysis indicates a spatial resolution of about 5 um, with detection efficiency exceeding 99 % and an impact parameter resolution of about 5.1 um. These promising results from this baseline vertex detector prototype mark a significant step toward realizing the optimal vertex detector for the CEPC.

physics.ins-det

Beam test of a 180 nm CMOS Pixel Sensor for the CEPC vertex detector

The proposed Circular Electron Positron Collider (CEPC) imposes new challenges for the vertex detector in terms of pixel size and material budget. A Monolithic Active Pixel Sensor (MAPS) prototype called TaichuPix, based on a column drain readout architecture, has been developed to address the need for high spatial resolution. In order to evaluate the performance of the TaichuPix-3 chips, a beam test was carried out at DESY II TB21 in December 2022. Meanwhile, the Data Acquisition (DAQ) for a muti-plane configuration was tested during the beam test. This work presents the characterization of the TaichuPix-3 chips with two different processes, including cluster size, spatial resolution, and detection efficiency. The analysis results indicate the spatial resolution better than 5 $μm$ and the detection efficiency exceeds 99.5 % for both TaichuPix-3 chips with the two different processes.

physics.ins-det

The performance of large-pitch AC-LGAD with different N+ dose

AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000~\SI{}{\micro\metre} and AC pad of 1000~\SI{}{\micro\metre}, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36~\SI{}{\micro\metre} to 16~\SI{}{\micro\metre} depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

physics.ins-det

Characterization of the response of IHEP-IME LGAD with shallow carbon to Gamma Irradiation

Low Gain Avalanche Detectors (LGAD) for the High-Granularity Timing Detector (HGTD) are crucial in reducing pileups in the High-Luminosity Large Hadron Collider. Numerous studies have been conducted on the bulk irradiation damage of LGADs. However, few studies have been carried out on the surface irradiation damage of LGAD sensors with shallow carbon implantation. In this paper, the IHEP-IME LGADs with shallow carbon implantation were irradiated up to 2 MGy using gamma irradiation to investigate surface damage. Important characteristic parameters, including leakage currents, breakdown voltage (BV), inter-pad resistances, and capacitances, were tested before and after irradiation. The results showed that the leakage current and BV increased after irradiation, whereas overall inter-pad resistance exhibited minimal change and remained above $10^9\ Ω$ before and after irradiation. Capacitance was found to be less than 4.5 pF with a slight decrease in the gain layer depletion voltage (V$_{gl}$) after irradiation. No parameter affected by the inter-pad separation was observed before and after irradiation. All characteristic parameters meet the requirements of HGTD, and this design can be used to further optimization.

physics.ins-det

XGC-VQA: A unified video quality assessment model for User, Professionally, and Occupationally-Generated Content

With the rapid growth of Internet video data amounts and types, a unified Video Quality Assessment (VQA) is needed to inspire video communication with perceptual quality. To meet the real-time and universal requirements in providing such inspiration, this study proposes a VQA model from a classification of User Generated Content (UGC), Professionally Generated Content (PGC), and Occupationally Generated Content (OGC). In the time domain, this study utilizes non-uniform sampling, as each content type has varying temporal importance based on its perceptual quality. In the spatial domain, centralized downsampling is performed before the VQA process by utilizing a patch splicing/sampling mechanism to lower complexity for real-time assessment. The experimental results demonstrate that the proposed method achieves a median correlation of $0.7$ while limiting the computation time below 5s for three content types, which ensures that the communication experience of UGC, PGC, and OGC can be optimized altogether.

cs.MM