SearcharxivSearch

arXiv subjects

Xiyang Huang

Publications and source records attributed to Xiyang Huang.

4 recordsLinked to original sources

Booster-based beam recycling for swap-out injection at the High Energy Photon Source

Fourth-generation synchrotron light sources employ ultralow-emittance storage rings with stringent injection requirements. On-axis swap-out injection alleviates the dependence on storage-ring dynamic aperture, but high-charge operation requires an efficient injector architecture capable of producing high-charge replacement bunches. This paper presents the accelerator physics design and performance analysis of a booster-based beam-recycling swap-out injection scheme implemented at the High Energy Photon Source (HEPS). In this approach, the full-energy booster serves as both an injector and a high-energy accumulator. An extracted storage-ring bunch is returned to the booster, merged with a low-charge bunch previously injected from the linac and accelerated to full energy. Following high-energy damping, the merged bunch is reinjected into the original storage-ring bucket. The scheme avoids the need for a dedicated accumulator ring while enabling high-charge bunch replacement. The recycling scheme was commissioned through staged machine studies. Full recycling-chain simulations, commissioning studies, and measured performance analysis are presented. The measured results characterize the recycling operation and quantify the transmission efficiency and performance limitations of the complete recycling loop. These results demonstrate the feasibility of the booster-based beam-recycling architecture and establish its operational basis for high-charge swap-out injection in future fourth-generation synchrotron light sources.

physics.acc-ph

Overview of the ClinicalSkillQA 2026 Shared Task on Continuous Perception and Procedural Reasoning in Clinical Skill Assessment

This paper presents an overview of the ClinicalSkillQA 2026 shared task, which was organized with the BioNLP Workshop at ACL 2026. The goal of this shared task is to evaluate continuous perception and procedural reasoning in clinical skill assessment by requiring systems to reconstruct the correct temporal order of shuffled clinical key frames and generate rationales grounded in clinical workflow knowledge. The benchmark contains 200 test-only instances sampled from clinical skill videos, covering three emergency-care procedures. Each instance is annotated with the ground-truth temporal order and an expert-verified rationale. A total of seven teams participated in the task, collectively making 90 submissions, with four teams providing system description papers. Systems are evaluated using Task Accuracy, Pairwise Accuracy, and BERTScore, which measure exact sequence reconstruction, local temporal consistency, and rationale quality, respectively. In this paper, we describe the task setup, dataset construction, and evaluation criteria. We further summarize the methodologies adopted by participating teams and present a comprehensive analysis of the submitted systems. The official results suggest that current models still struggle with continuous perception and procedural reasoning, especially when they must integrate visual evidence, temporal structure, and clinical workflow knowledge.

cs.HC

SiMing-Bench: Evaluating Procedural Correctness from Continuous Interactions in Clinical Skill Videos

Current video benchmarks for multimodal large language models (MLLMs) focus on event recognition, temporal ordering, and long-context recall, but overlook a harder capability required for expert procedural judgment: tracking how ongoing interactions update the procedural state and thereby determine the correctness of later actions. We introduce SiMing-Bench, the first benchmark for evaluating this capability from full-length clinical skill videos. It targets rubric-grounded process-level judgment of whether interaction-driven state updates preserve procedural correctness across an entire workflow. SiMing-Bench is instantiated with SiMing-Score, a physician-annotated dataset of real clinical skill examination videos spanning cardiopulmonary resuscitation, automated external defibrillator operation, and bag-mask ventilation, each paired with a standardized step-wise rubric and dual-expert labels. Across diverse open- and closed-source MLLMs, we observe consistently weak agreement with physician judgments. Moreover, weak performance on rubric-defined intermediate steps persists even when overall procedure-level correlation appears acceptable, suggesting that coarse global assessment substantially overestimates current models' procedural judgment ability. Additional analyses with binary step judgment and step-aligned clips indicate that the bottleneck is not merely fine-grained scoring or temporal localization, but modeling how continuous interactions update procedural state over time.

cs.CV

Suppression of the emittance growth induced by coherent synchrotron radiation in triple-bend achromats

The coherent synchrotron radiation (CSR) effect in a bending path plays an important role in transverse emittance dilution in high-brightness light sources and linear colliders, where the electron beams are of short bunch length and high peak current. Suppression of the emittance growth induced by CSR is critical to preserve the beam quality and help improve the machine performance. It has been shown that the CSR effect in a double-bend achromat (DBA) can be analyzed with the two-dimensional point-kick analysis method. In this paper, this method is applied to analyze the CSR effect in a triple-bend achromat (TBA) with symmetric layout, which is commonly used in the optics designs of energy recovery linacs (ERLs). A condition of cancelling the CSR linear effect in such a TBA is obtained, and is verified through numerical simulations. It is demonstrated that emittance preservation can be achieved with this condition, and to a large extent, has a high tolerance to the fluctuation of the initial transverse phase space distribution of the beam.

physics.acc-ph