SearcharxivSearch

arXiv subjects

Xuening Cao

Publications and source records attributed to Xuening Cao.

7 recordsLinked to original sources

Power-efficient ultra-broadband soliton microcombs in resonantly-coupled microresonators

The drive to miniaturize optical frequency combs for practical deployment has spotlighted microresonator solitons as a promising chip-scale candidate. However, these soliton microcombs could be very power-hungry when their span increases, especially with fine comb spacings. As a result, realizing an octave-spanning comb at microwave repetition rates for direct optical-microwave linkage is considered not possible for photonic integration due to the high power requirements. Here, we introduce the concept of resonant-coupling to soliton microcombs to reduce pump consumption significantly. Compared to conventional waveguide-coupled designs, we demonstrate (i) a threefold increase in spectral span for high-power combs and (ii) up to a tenfold reduction in repetition frequency for octave-spanning operation. This configuration is compatible with laser integration and yields reliable, turnkey soliton generation. By eliminating the long-standing pump-power bottleneck, microcombs will soon become readily available for portable optical clocks, massively parallel data links, and field-deployable spectrometers.

physics.optics

Integrated optomechanical ultrasonic sensors with nano-Pascal-level sensitivity

Ultrasonic sensors are widely used for object detection and localization in underwater and biological settings. The operational range and spatial resolution are inherently limited by sensor sensitivity, in which conventional piezoelectric transducers have been overwhelmed by advanced photonic sensors. Here, we demonstrate an optomechanical ultrasonic sensor integrated into a photonic platform, which comprises a suspended SiO2 membrane embedded with a high-Q Si3N4 microring resonator. By exploiting simultaneous optical and mechanical resonances, the sensor achieves a record low noise-equivalent pressure (NEP) of 218 nPa/Hz^1/2 at 289 kHz in air and 9.6 nPa/Hz^1/2 at 52 kHz in water. We demonstrate its versatility through photoacoustic gas spectroscopy in air and underwater ultrasound imaging, achieving a minimum detectable C2H2 concentration of 2.9 ppm (integration time 1 s) and an imaging resolution of 1.89 mm, respectively. Our work represents a significant advancement in compact CMOS-compatible ultrasound sensing, unlocking new possibilities in biomedical imaging, environmental monitoring, industrial testing, and underwater communications.

physics.optics

Compact Turnkey Soliton Microcombs at Microwave Rates via Wafer-Scale Fabrication

Soliton microcombs generated in nonlinear microresonators facilitate the photonic integration of timing, frequency synthesis, and astronomical calibration functionalities. For these applications, low-repetition-rate soliton microcombs are essential as they establish a coherent link between optical and microwave signals. However, the required pump power typically scales with the inverse of the repetition rate, and the device footprint scales with the inverse of square of the repetition rate, rendering low-repetition-rate soliton microcombs challenging to integrate within photonic circuits. This study designs and fabricates silicon nitride microresonators on 4-inch wafers with highly compact form factors. The resonator geometries are engineered from ring to finger and spiral shapes to enhance integration density while attaining quality factors over 10^7. Driven directly by an integrated laser, soliton microcombs with repetition rates below 10 GHz are demonstrated via turnkey initiation. The phase noise performance of the synthesized microwave signals reaches -130 dBc/Hz at 100 kHz offset frequency for 10 GHz carrier frequencies. This work enables the high-density integration of soliton microcombs for chip-based microwave photonics and spectroscopy applications.

physics.optics

Picotesla-sensitivity microcavity optomechanical magnetometry

Cavity optomechanical systems have enabled precision sensing of magnetic fields, by leveraging the optical resonance-enhanced readout and mechanical resonance-enhanced response. Previous studies have successfully achieved scalable and reproducible microcavity optomechanical magnetometry (MCOM) by incorporating Terfenol-D thin films into high-quality ($Q$) factor whispering gallery mode (WGM) microcavities. However, the sensitivity was limited to 585 pT/Hz$^{1/2}$, over 20 times inferior to those using Terfenol-D particles. In this work, we propose and demonstrate a high-sensitivity and scalable MCOM approach by sputtering a FeGaB thin film onto a high-$Q$ SiO$_2$ WGM microdisk. Theoretical studies are conducted to explore the magnetic actuation constant and noise-limited sensitivity by varying the parameters of the FeGaB film and SiO$_2$ microdisk. Multiple magnetometers with different radii are fabricated and characterized. By utilizing a microdisk with a radius of 355 $μ$m and a thickness of 1 $μ$m, along with a FeGaB film with a radius of 330 $μ$m and a thickness of 1.3 $μ$m, we have achieved a remarkable peak sensitivity of 1.68 pT/Hz$^{1/2}$ at 9.52 MHz. This represents a significant improvement of over two orders of magnitude compared with previous studies employing sputtered Terfenol-D film. Notably, the magnetometer operates without a bias magnetic field, thanks to the remarkable soft magnetic properties of the FeGaB film. Furthermore, as a proof-of-concept, we have demonstrated the real-time measurement of a pulsed magnetic field simulating the corona current in a high-voltage transmission line using our developed magnetometer. These high-sensitivity magnetometers hold great potential for various applications, such as magnetic induction tomography and corona current monitoring.

physics.optics

Ultrasound sensing with optical microcavities

Nowadays, ultrasound sensors are playing an irreplaceable role in the fields of biomedical imaging and industrial nondestructive inspection. Currently, piezoelectric transducers are the most widely used ultrasound sensors, but their sensitivities drop quickly when the size becomes smaller, leading to a typical sensor size at the millimeter to centimeter scale. In order to realize both high sensitivity and spatial resolution, various optical ultrasound sensors have been developed. Among them, ultrasound sensors using high-$Q$ optical microcavities have realized unprecedented sensitivities and broad bandwidth and can be mass-produced on a silicon chip. In this review, we introduce ultrasound sensors using three types of optical microcavities, including Fabry-Perot cavities, $π$-phase-shifted Bragg gratings, and whispering gallery mode microcavities. We introduce the sensing mechanisms using optical microcavities and discuss several key parameters for ultrasound sensors. We then review the recent work on ultrasound sensing using these three types of microcavities and their applications in practical detection scenarios, such as photoacoustic imaging, ranging, and particle detection.

physics.optics

Micropascal-sensitivity ultrasound sensors based on optical microcavities

Whispering gallery mode (WGM) microcavities have been widely used for high-sensitivity ultrasound detection, due to their optical and mechanical resonances enhanced sensitivity. The ultrasound sensitivity of the cavity optomechanical system is fundamentally limited by the thermal noise. In this work, we theoretically and experimentally investigate the thermal-noise-limited sensitivity of a WGM microdisk ultrasound sensor, and optimize the sensitivity by varying the radius and thickness of the microdisk, as well as using a trench structure around the disk. Using a microdisk with a radius of 300 um and thickness of 2 um, a peak sensitivity of 1.18 uPa Hz^{-1/2} is achieved at 82.6 kHz, which is to our knowledge the record sensitivity among the cavity optomechanical ultrasound sensors. Such high sensitivity can improve the detection range of air-coupled ultrasound sensing technology.

physics.optics

High sensitivity air-coupled MHz frequency ultrasound detection using on-chip microcavities

Owing to their dual-resonance enhanced sensitivity, cavity optomechanical systems provide an ideal platform for ultrasound sensing. In this work, we realize high sensitivity air-coupled ultrasound sensing from kilohertz (kHz) to megahertz (MHz) frequency range based on whispering gallery mode microcavities. Using a 57 um-diameter microtoroid with high optical Q factor (~10^7) and mechanical Q factor (~700), we achieve sensitivities of 46 uPa Hz^{-1/2}-10 mPa Hz^{-1/2} in a frequency range of 0.25-3.2 MHz. Thermal-noise-limited sensitivity is realized around the mechanical resonance at 2.56 MHz, in a frequency range of 0.6 MHz. We also observe the second- and third-order mechanical sidebands, and quantitatively study the intensities of each mechanical sideband as a function of the mechanical displacement. Measuring the combination of signal to noise ratios at all sidebands has the potential to extend the dynamic range of ultrasound sensing. In addition, to improve the ultrasound sensitivity in the kHz frequency range, we use a microdisk with a diameter of 200 um, and achieve sensitivities of 1.83 uPa Hz^{-1/2}-10.4 mPa Hz^{-1/2} in 30 kHz-1.65 MHz range.

physics.optics