SearcharxivSearch

arXiv subjects

Xun Jia

Publications and source records attributed to Xun Jia.

At least 19 recordsLinked to original sources

Physics-Assisted Deep Learning Denoising for Stabilized IMPULSED dMRI Microenvironment Parameter Fitting

Diffusion-weighted MRI (dMRI) is a powerful tool for quantifying cellular microenvironment parameters. This study proposes a physics-assisted deep learning (DL)-based denoising framework designed to enhance dMRI signal quality and improve the robustness of subsequent biophysical model fitting. A dataset of paired noise-free and Rician-noise-corrupted dMRI signals was generated using the IMPULSED-dMRI signal model. Three denoising architectures were evaluated: Convolutional Neural Networks (CNN), Multilayer Perceptron (MLP), and Long Short-Term Memory (LSTM) networks. Denoised signals were then fitted to estimate cell diameter $d$, intracellular volume fraction $V_{\mathrm{in}}$, and extracellular apparent diffusion coefficient $D_\mathrm{ex}$. DL-based processing substantially improved dMRI signal denoising. The MLP and LSTM achieved similar performance, with the LSTM slightly better overall, and both outperformed the CNN. In the subsequent model fitting step, the LSTM produced modest reductions in parameter MAE. The dominant benefit was fitting stabilization, with the overall fitting failure rate reduced from 57.6\% to 17.7\%. The proposed framework improves dMRI signal quality and stabilizes subsequent IMPULSED-based microenvironmental parameter fitting.

physics.med-ph

Investigating the Uncertainty of Cellular Microenvironment Parameter Estimations via Diffusion MRI Cytometry

This study aims to identify cell microenvironment parameters that can be robustly estimated from IMPULSED diffusion MRI signals and to develop a reliable mapping-based estimation framework. Diffusion MRI signals were simulated using the established IMPULSED model with one pulsed gradient spin echo sequence and two oscillating gradient spin echo sequences at different frequencies. Five cellular parameters were considered: cell diameter ($d$), intracellular diffusion coefficient ($D_{in}$), intracellular volume fraction ($V_{in}$), extracellular diffusion coefficient ($D_{ex}$), and the frequency-dependent slope of $D_{ex}$ ($\beta_{ex}$). Parameter uncertainty was quantified using Jacobian-based sensitivity analysis at an SNR of 30, representing clinically achievable conditions on a 1.5T MRI scanner. To enable direct parameter mapping, signals were logarithmically transformed, reduced in dimension using principal component analysis, and then used to estimate parameters with linear regression, fourth-order polynomial regression, and a fully connected four-layer neural network. Model validation was performed in vitro using MC38 cell lines. Uncertainty analysis identified $d$, $V_{in}$, and $D_{ex}$ as robustly derivable parameters, each with relative uncertainty below 1.0. Among the tested models, the four-layer neural network performed best, with mean absolute errors of 1.7 $\mu$m for $d$, 5.06% for $V_{in}$, and 0.28 $\mu$m$^2$/ms for $D_{ex}$. In vitro validation showed a 6.7% error in cell diameter estimation. These results demonstrate that IMPULSED dMRI can support robust estimation of key cell microenvironment parameters and provide a practical framework for noninvasive assessment of tumor microenvironment changes during radiation therapy response monitoring.

physics.med-ph

A Machine-to-Machine Knowledge-Guided LLM Agent for Generalizable Radiotherapy Treatment Planning

In this work, we propose a prototype machine-to-machine (M2M) knowledge-guided Large Language Model (LLM) framework for automated radiotherapy treatment planning. In the proposed paradigm, Treatment Planning Parameter (TPP) distribution knowledge discovered by a Deep Reinforcement Learning (DRL) agent is transferred to an LLM agent through in-context learning, enabling autonomous iterative planning without human intervention. While standard LLM-based planning often lacks physical intuition and struggles with convergence, the integration of DRL-derived guidance constrains the agent to a physically valid parameter space. Experimental evaluations are performed across three diverse planning scenarios: basic prostate cases, complex prostate configurations with increased organ-at-risk (OAR) constraints, and liver cases. The evaluation results demonstrate that the guided LLM agent consistently achieves optimal planning scores while significantly reducing the number of iterations compared to unguided planning. Analysis of the final TPP configurations reveals that the agent successfully learns a hierarchical priority of objectives, effectively restoring a logical "cause-and-effect" relationship between parameter tuning and dosimetric outcomes. Crucially, this prototype framework exhibits robust generalizability, maintaining high planning quality regardless of specific patient anatomy, treatment site, or initial plan quality. By bridging the specialized optimization of DRL with the adaptive reasoning of LLMs, this M2M framework establishes a scalable foundation towards generalizable autonomous treatment planning, ultimately benefiting clinical practice in realistic environments.

physics.med-ph

Large Language Models for AI-Assisted Radiotherapy Scheduling: A Feasibility Study Under Realistic Operational Constraints

Radiotherapy (RT) patient scheduling is a complex operational problem. Current scheduling often relies on manual coordination and can be difficult to adapt to changing clinical demands. This study evaluated the feasibility of using a large language model (LLM) to generate candidate RT patient schedules satisfying predefined clinical and operational constraints. A simulated three-LINAC RT scheduling environment was developed over one year using synthetic patient arrivals and treatment characteristics modeled after clinical practice. A total of 1,400 new patients across 12 treatment categories were generated. An LLM-based scheduling framework used structured natural-language prompts encoding clinical rules, operational constraints, and scheduling objectives. Performance was evaluated across scenarios involving weekly time consistency, LINAC continuity, gap-constrained temporal relaxation, and infeasible request handling. Generated schedules were validated using deterministic rule-based checks and manual review. LLM-generated schedules satisfied predefined feasibility rules in the evaluated scenarios. Approximately 99% of evaluated fractions remained within the preferred 60-minute weekly treatment-time window. Adding a LINAC-continuity objective reduced LINAC switching from 54.6% to 10.1%. Adding gap-constrained temporal relaxation reduced Friday mean daily gap time from 169.5 to 89.2 minutes while maintaining approximately 99% of fractions within the 60-minute window. The framework also identified infeasible scheduling requests and proposed interpretable corrective actions. These results suggested that LLMs may support RT patient scheduling in constraint-rich simulated clinical environments, motivating further investigation of LLM-assisted scheduling as a flexible, human-in-the-loop decision-support approach for RT operations.

physics.med-ph

Optimizing IMPULSED Acquisition Protocols for Clinical 3T Scanners Through Bayesian Experimental Design

To optimize diffusion MRI acquisition protocols for IMPULSED model at clinical 3T scanner using Bayesian experimental design, enabling accurate cellular-scale parameter estimation under realistic scan time and scanner hardware constraints. Expected Information Gain (EIG) was used as the optimization objective to maximize the information content of acquired measurements for IMPULSED model fitting. Bayesian optimization with Gaussian process surrogates efficiently searched the high-dimensional acquisition parameter space, including pulse types (PGSE, OGSEn1, and OGSEn2), diffusion times, and b-values. Optimized protocols were systematically evaluated against a heuristically designed baseline protocol through simulation studies assessing classification accuracy and parameter estimation performance across SNR levels of 5-40. Robustness to optimization assumptions was examined by varying prior distributions and assumed SNR. In-vivo validation was performed using canine tumor data acquired at 3T. The optimized protocol eliminated OGSEn2 acquisitions, concentrated measurements at high b-values, employing concurrently optimized diffusion timing. Compared to the baseline protocol, the optimized design achieved superior classification accuracy for distinguishing cell populations and reduced parameter estimation error across biologically relevant parameter ranges at various SNRs. Performance advantages were consistent across diverse optimization scenarios, demonstrating robustness to prior knowledge and noise assumptions. In-vivo parameter maps showed substantially improved quality and smoothness. Bayesian optimization substantially improves IMPULSED acquisition design for clinical 3T scanners. This principled, algorithm-agnostic framework enables accurate diffusion MRI cytometry under clinical constraints, with potential applications to tumor characterization and treatment monitoring.

physics.med-ph

Human-like AI-based Auto-Field-in-Field Whole-Brain Radiotherapy Treatment Planning With Conversation Large Language Model Feedback

Whole-brain radiotherapy (WBRT) is a common treatment due to its simplicity and effectiveness. While automated Field-in-Field (Auto-FiF) functions assist WBRT planning in modern treatment planning systems, it still requires manual approaches for optimal plan generation including patient-specific hyperparameters definition and plan refinement based on quality feedback. This study introduces an automated WBRT planning pipeline that integrates a deep learning (DL) Hyperparameter Prediction model for patient-specific parameter generation and a large-language model (LLM)-based conversational interface for interactive plan refinement. The Hyperparameter Prediction module was trained on 55 WBRT cases using geometric features of clinical target volume (CTV) and organs at risk (OARs) to determine optimal Auto-FiF settings in RayStation treatment planning system. Plans were generated under predicted hyperparameters. For cases in which the generated plan was suboptimal, quality feedback via voice input was captured by a Conversation module, transcribed using Whisper, and interpreted by GPT-4o to adjust planning settings. Plan quality was evaluated in 15 independent cases using clinical metrics and expert review, and model explainability was supported through analysis of feature importance. Fourteen of 15 DL-generated plans were clinically acceptable. Normalized to identical CTV D95% as the clinical plans, the DL-generated and clinical plans showed no statistically significant differences in doses to the eyes, lenses, or CTV dose metrics D1% and D99%. The DL-based planning required under 1 minute of computation and achieved total workflow execution in approximately 7 minutes with a single mouse click, compared to 15 minutes for manual planning. In cases requiring adjustment, the Conversational module successfully improved dose conformity and hotspot reduction.

physics.med-ph

Towards Human-Centric Intelligent Treatment Planning for Radiation Therapy

Current radiation therapy treatment planning is limited by suboptimal plan quality, inefficiency, and high costs. This perspective paper explores the complexity of treatment planning and introduces Human-Centric Intelligent Treatment Planning (HCITP), an AI-driven framework under human oversight, which integrates clinical guidelines, automates plan generation, and enables direct interactions with operators. We expect that HCITP will enhance efficiency, potentially reducing planning time to minutes, and will deliver personalized, high-quality plans. Challenges and potential solutions are discussed.

physics.med-ph

New Insights into Automatic Treatment Planning for Cancer Radiotherapy Using Explainable Artificial Intelligence

Objective: This study aims to uncover the opaque decision-making process of an artificial intelligence (AI) agent for automatic treatment planning. Approach: We examined a previously developed AI agent based on the Actor-Critic with Experience Replay (ACER) network, which automatically tunes treatment planning parameters (TPPs) for inverse planning in prostate cancer intensity modulated radiotherapy. We selected multiple checkpoint ACER agents from different stages of training and applied an explainable AI (EXAI) method to analyze the attribution from dose-volume histogram (DVH) inputs to TPP-tuning decisions. We then assessed each agent's planning efficacy and efficiency and evaluated their policy and final TPP tuning spaces. Combining these analyses, we systematically examined how ACER agents generated high-quality treatment plans in response to different DVH inputs. Results: Attribution analysis revealed that ACER agents progressively learned to identify dose-violation regions from DVH inputs and promote appropriate TPP-tuning actions to mitigate them. Organ-wise similarities between DVH attributions and dose-violation reductions ranged from 0.25 to 0.5 across tested agents. Agents with stronger attribution-violation similarity required fewer tuning steps (~12-13 vs. 22), exhibited a more concentrated TPP-tuning space with lower entropy (~0.3 vs. 0.6), converged on adjusting only a few TPPs, and showed smaller discrepancies between practical and theoretical tuning steps. Putting together, these findings indicate that high-performing ACER agents can effectively identify dose violations from DVH inputs and employ a global tuning strategy to achieve high-quality treatment planning, much like skilled human planners. Significance: Better interpretability of the agent's decision-making process may enhance clinician trust and inspire new strategies for automatic treatment planning.

physics.med-ph

R-Index: A Robust Metric for IVIM Parameter Estimation on Clinical MRI Scanners

Background: Intravoxel Incoherent Motion (IVIM) model characterizes both water diffusion and perfusion in tissues, providing quantitative biomarkers valuable for tumor tissue characterization. However, parameter estimation based on this model is challenging due to its ill-posed nature, resulting in poor reproducibility, particularly at low signal to noise ratios (SNRs) in a clinic scenario. Purpose: This study analyzes the uncertainty of IVIM model fitting, quantifies parameter collinearity, and introduces a new index with enhanced robustness to enhance clinical applicability of the IVIM model. Study Type: Prospective. Population: One healthy volunteer. Field Strength/Sequence: 1.5T; single-shot EPI DWI. Assessment: The probability distributions of estimated IVIM parameters were evaluated across a clinically relevant range. Collinearity among parameters was assessed and a new metric, the R-index, was proposed. The R-index linearly combines individual IVIM parameters to mitigate collinearity and reduce estimation uncertainty. Simulation and a volunteer study was conducted to validate the presence of parameter collinearity and to assess the robustness of the R-index. Statistical Tests: N/A Results: In simulation studies with a typical clinical setting (SNR = 20), normalized IVIM parameters exhibited mean standard deviations ranging from 0.107 to 0.269, while the R-index showed a reduced deviation of 0.064. Repeated scans in a healthy volunteer confirmed the presence of parameter collinearity, with 32% of voxels exhibiting statistically significant correlations (p < 0.05) among fitted IVIM parameters, and a mean Pearson correlation coefficient of r = -0.96. Data Conclusion: The R-index provides a robust metric for IVIM model fitting under low SNR conditions typical of clinical MRI, offering improved reproducibility and potential for broader clinical applicability.

physics.med-ph

Lattice-charge coupling in a trilayer nickelate with intertwined density wave order

Intertwined charge and spin correlations are ubiquitous in a wide range of transition metal oxides and are often perceived as intimately related to unconventional superconductivity. Theoretically envisioned as driven by strong electronic correlations, the intertwined order is usually found to be strongly coupled to the lattice as signaled by pronounced phonon softening. Recently, both charge/spin density waves (CDW/SDW) and superconductivity have been discovered in several Ruddlesden-Popper (RP) nickelates, in particular trilayer nickelates RE4Ni3O10 (RE=Pr, La). The nature of the intertwined order and the role of lattice-charge coupling are at the heart of the debate about these materials. Using inelastic X-ray scattering, we mapped the phonon dispersions in RE4Ni3O10 and found no evidence of phonon softening near the CDW wavevector over a wide temperature range. Calculations of the electronic susceptibility revealed a peak at the observed SDW ordering vector but not at the CDW wavevector. The absence of phonon softening is in sharp contrast to that in canonical oxide materials, notably cuprates. Our experimental and theoretical findings highlight the crucial role of the spin degree of freedom and establish a foundation for understanding the interplay between superconductivity and density-wave transitions in RP nickelate superconductors and beyond.

cond-mat.str-el

Actor Critic with Experience Replay-based automatic treatment planning for prostate cancer intensity modulated radiotherapy

Background: Real-time treatment planning in IMRT is challenging due to complex beam interactions. AI has improved automation, but existing models require large, high-quality datasets and lack universal applicability. Deep reinforcement learning (DRL) offers a promising alternative by mimicking human trial-and-error planning. Purpose: Develop a stochastic policy-based DRL agent for automatic treatment planning with efficient training, broad applicability, and robustness against adversarial attacks using Fast Gradient Sign Method (FGSM). Methods: Using the Actor-Critic with Experience Replay (ACER) architecture, the agent tunes treatment planning parameters (TPPs) in inverse planning. Training is based on prostate cancer IMRT cases, using dose-volume histograms (DVHs) as input. The model is trained on a single patient case, validated on two independent cases, and tested on 300+ plans across three datasets. Plan quality is assessed using ProKnow scores, and robustness is tested against adversarial attacks. Results: Despite training on a single case, the model generalizes well. Before ACER-based planning, the mean plan score was 6.20$\pm$1.84; after, 93.09% of cases achieved a perfect score of 9, with a mean of 8.93$\pm$0.27. The agent effectively prioritizes optimal TPP tuning and remains robust against adversarial attacks. Conclusions: The ACER-based DRL agent enables efficient, high-quality treatment planning in prostate cancer IMRT, demonstrating strong generalizability and robustness.

physics.med-ph

A universal bioluminescence tomography system for pre-clinical image-guided radiotherapy research

CBCT-guided small animal irradiators encounter challenges in localizing soft-tissue targets due to low imaging contrast. Bioluminescence tomography (BLT) offers a promising solution, but they have largely remained in laboratorial development, limiting accessibility for researchers. In this work, we develop a universal, commercial-graded BLT-guided system (MuriGlo) designed to seamlessly integrate with commercial irradiators and empower researchers for translational studies. We demonstrate its capabilities in supporting in vitro and in vivo studies. The MuriGlo comprises detachable mouse bed, thermostatic control, mirrors, filters, and CCD, enabling multi-projection and multi-spectral imaging. We evaluate that the thermostatic control effectively sustains animal temperature at 37{\deg}C throughout imaging, and quantify that the system can detect as few as 61 GL261-AkaLuc cells in vitro. To illustrate how the MuriGlo can be utilized for in vivo image-guided research, we present 3 strategies, BLT-guided 5-arc, 2-field box, and BLI-guided single-beam, ranging from complicated high-conformal to simplest high-throughput plans. The high conformal BLT-guided 5-arc plan fully covers the gross tumor volume (GTV) at prescribed dose with minimal normal tissue exposure (3.9%), while the simplified, high-throughput BLT-guided 2-field box achieves 100% GTV coverage but results in higher normal tissue exposure (13.1%). Moreover, we demonstrate that the localization accuracy of MuriGlo for both widely-used SARRP and SmART irradiators is within1 mm, and the tumor coverage reaches over 97% with 0.75mm margin. The universal BLT-guided system offers seamless integration with commercial irradiators, achieving comparable localization accuracy, expected to supporting high-precision radiation research.

physics.med-ph

Chiral Spin-Liquid-Like State in Pyrochlore Iridate Thin Films

The pyrochlore iridates have become ideal platforms to unravel fascinating correlated and topolog?ical phenomena that stem from the intricate interplay among strong spin-orbit coupling, electronic correlations, lattice with geometric frustration, and itinerancy of the 5d electrons. The all-in-all?out antiferromagnetic state, commonly considered as the magnetic ground state, can be dramatically altered in reduced dimensionality, leading to exotic or hidden quantum states inaccessible in bulk. Here, by means of magnetotransport, resonant elastic and inelastic x-ray scattering experiments, we discover an emergent quantum disordered state in (111) Y2Ir2O7 thin films (thickness less than 30 nm) per?sisting down to 5 K, characterized by dispersionless magnetic excitations. The anomalous Hall effect observed below an onset temperature near 135 K corroborates the presence of chiral short-range spin configurations expressed in non-zero scalar spin chirality, breaking the macroscopic time-reversal symmetry. The origin of this chiral state is ascribed to the restoration of magnetic frustration on the pyrochlore lattice in lower dimensionality, where the competing exchange interactions together with enhanced quantum fluctuations suppress any long-range order and trigger spin-liquid-like behavior with degenerate ground-state manifold.

cond-mat.str-el

Mathematical Modeling of the Synergetic Effect between Radiotherapy and Immunotherapy

Achieving effective synergy between radiotherapy and immunotherapy is critical for optimizing tumor control and treatment outcomes. To explore the underlying mechanisms of this synergy, we have investigated a novel treatment approach known as personalized ultra-fractionated stereotactic adaptive radiation therapy (PULSAR), which emphasizes the impact of radiation timing on treatment efficacy. However, the precise mechanism remains unclear. Building on insights from small animal PULSAR studies, we developed a mathematical framework consisting of multiple ordinary differential equations to elucidate the temporal dynamics of tumor control resulting from radiation and the adaptive immune response. The model accounts for the migration and infiltration of T-cells within the tumor microenvironment. This proposed model establishes a causal and quantitative link between radiation therapy and immunotherapy, providing a valuable in-silico analysis tool for designing future PULSAR trials.

q-bio.QM

Experimental and Numerical Investigations on Robustness of a Deep Neural Network-based Multi-class Classification Model of CT Images with respect to Image Noise

Robustness of Deep Neural Networks (DNNs) is an important aspect to consider for their clinical applications. This work examined robustness issue for a DNN-based multi-class classification model via comprehensive experimental and simulation studies. We constructed a DNN-based multi-class classification model that classifies an axial CT image as one of the four body sites of brain & neck (BN), chest (C), abdomen & pelvis (AP), and leg & foot (LF). The model was trained with whole-body CT images of 37 patients each scanned once and 10 scans of a whole-body phantom with different mAs levels to achieve a F1 score of 99.7% averaged over four classes on a testing dataset. We evaluated robustness of the model against noise perturbations under different mAs levels using simulated CT noisy images based on noise power spectrum (NPS) and experimental CT images acquired in repeated scans of the orange-man phantom. To quantify robustness of the trained model, we defined Successful Attack Rate (SAR) as the ratio of predictions changed with noises and Confusion Matrix for Robustness (CMR) that represents the percentage of a predicted class without noise being predicted to different classes under noise. Besides, we repeatedly trained the model for 100 times using exactly the same training procedure, hyper-parameter settings, as well as the training and validation dataset to investigate robustness of models due to inherent randomness in the training process. Finally, to improve model robustness, we employed an adaptive training scheme and demonstrated its effectiveness. Experimental and numerical studies demonstrated robustness issue of a DNN-based multi-class classification model. The discoveries highlight the needs for evaluating and ensuring DNN model robustness.

physics.med-ph

Joint k-TE Space Image Reconstruction and Data Fitting for T2 Mapping

Objectives: To develop a joint k-TE reconstruction algorithm to reconstruct the T2-weighted (T2W) images and T2 map simultaneously. Materials and Methods: The joint k-TE reconstruction model was formulated as an optimization problem subject to a self-consistency condition of the exponential decay relationship between the T2W images and T2 map. The objective function included a data fidelity term enforcing the agreement between the solution and the measured k-space data, together with a spatial regularization term on image properties of the T2W images. The optimization problem was solved using Alternating-Direction Method of Multipliers (ADMM). We tested the joint k-TE method in phantom data and healthy volunteer scans with fully-sampled and under-sampled k-space lines. Image quality of the reconstructed T2W images and T2 map, and the accuracy of T2 measurements derived by the joint k- TE and the conventional signal fitting method were compared. Results: The proposed method improved image quality with reduced noise and less artifacts on both T2W images and T2 map, and increased measurement consistency in T2 relaxation time measurements compared with the conventional method in all data sets. Conclusions: The proposed reconstruction method outperformed the conventional magnitude image-based signal fitting method in image quality and stability of quantitative T2 measurements

physics.med-ph

Interplay of broken symmetry and delocalized excitations in the insulating state of 1$T$-TaS$_2$

Coexistence of localized and extended excitations is central to the macroscopic properties of correlated materials. For 5d transition metal compounds, electron correlations alone generally do not lead to a metal-insulator (Mott) transition, with insulating behavior usually resulting from their coupling with magnetic ordering and/or structural distortions. 1$T$-TaS$_2$ is a prototypical example of such correlated insulating behavior, with a high-symmetry metallic phase transforming into a distorted, charge density wave (CDW) insulating state at low temperatures. The relevance of the localized electron physics at play in 3d compounds to these 5d transition metal compounds remains an open question. We resolved this standing controversy in 1$T$-TaS$_2$ combining resonant inelastic X-ray spectroscopy and first-principles calculations. We observed five electronic excitations arising from the interband transitions of the Ta 5d orbitals and the S 3p ligand state, with none of the excitations on the order of the Mott gap. These excitations cannot be explained within the framework of standard multiplet calculations that assume a localized wavefunction, but instead, are captured by a band theory framework accounting for the low symmetry of the crystal field in the CDW state. Our findings suggest that the electronic property of 1$T$-TaS$_2$ is dominated by both plasmonic quasiparticles and inter-band transitions associated with a Drude-type response, with no resonance associated with a putative Mott transition. Our discovery provides new insights into the electron localization and the onset of insulating behavior in 5d transition metal materials.

cond-mat.mtrl-sci

Top-level Design and Simulated Performance of the First Portable CT-MR scanner

Multi-modality imaging hardware can be integrated in a single gantry to collect diverse datasets for complementary information and spatiotemporal correlation, with excellent examples including PET-CT and PET-MRI. However, there is no CT-MRI prototype up to today due to technical challenges and associated cost-benefit considerations. Thanks to the rapid development of medical imaging, it becomes feasible now to integrate cost-effective CT and MRI imagers together for portability, popularity, and point of care. In this paper, we present the top-level design of the first portable CT-MRI system and evaluate its imaging performance via realistic numerical simulations. In this CT-MRI system, the magnet made of two NdFeB rings of about 40.0 cm radius forms a magnetic field of about 57 mT at the isocenter and has a gap of 11.3 cm to accommodate the rotating CT gantry. The targeted MR imaging field of view (FOV) is a sphere of ~15 cm in diameter and that of CT is approximately 20 cm diameter in axial direction and 5 cm in longitudinal direction. Our results show a great potential of such a hybrid system. The proposed CT-MRI system will be valuable in applications such as imaging in underdeveloped countries, disaster scenes and battle fields.

physics.med-ph