Searcharxiv⌕ Search

arXiv subjects

Y. Choi

Publications and source records attributed to Y. Choi.

427 records · Page 24Linked to original sources

Magnetic Structure in Fe/Sm-Co Exchange Spring Bilayers with Intermixed Interfaces

The depth profile of the intrinsic magnetic properties in an Fe/Sm-Co bilayer fabricated under nearly optimal spring-magnet conditions was determined by complementary studies of polarized neutron reflectometry and micromagnetic simulations. We found that at the Fe/Sm-Co interface the magnetic properties change gradually at the length scale of 8 nm. In this intermixed interfacial region, the saturation magnetization and magnetic anisotropy are lower and the exchange stiffness is higher than values estimated from the model based on a mixture of Fe and Sm-Co phases. Therefore, the intermixed interface yields superior exchange coupling between the Fe and Sm-Co layers, but at the cost of average magnetization.

cond-mat.mtrl-sci↗

Observation of Bs->Ds(*)+Ds(*)- using e+e- collisions and a determination of the Bs-Bsbar width difference ΔΓ_s

We have made the first observation of Bs->Ds(*)+Ds(*)- decays using 23.6 fb-1 of data recorded by the Belle experiment running on the Upsilon(5S) resonance. The branching fractions are measured to be B(B^0_s\ra D^+_s D^-_s) = (1.0\,^{+0.4}_{-0.3}\,^{+0.3}_{-0.2})%, B(B^0_s\ra D^{*\pm}_s D^{\mp}_s) = (2.8\,^{+0.8}_{-0.7}\,\pm 0.7)%, and B(B^0_s\ra D^{*+}_s D^{*-}_s) = (3.1\,^{+1.2}_{-1.0}\,\pm 0.8)%; the sum is B(B^0_s\ra D^{(*)+}_s D^{(*)-}_s) = (6.9\,^{+1.5}_{-1.3}\,\pm 1.9)%. Assuming Bs->Ds(*)+Ds(*)- saturates decays to CP-even final states, the branching fraction determines the ratio ΔΓ_s/cos(ϕ), where ΔΓ_s is the difference in widths between the two Bs-Bsbar mass eigenstates, and ϕis a CP-violating weak phase. Taking CP violation to be negligibly small, we obtain ΔΓ_s/Γ_s = 0.147^{+0.036}_{-0.030}(stat.)^{+0.044}_{-0.042}(syst.), where Γ_s is the mean decay width.

hep-ex↗

Measurement of CP violating asymmetries in B^0 -> K^+K^- K^0_S decays with a time-dependent Dalitz approach

We report a measurement of $CP$ violating asymmetries in $B^0(\overline{B}^0) \to K^+ K^- K^0_S$ decays with a time-dependent Dalitz approach. This analysis is based on a data sample of $657\times 10^6$ $B\overline{B}$ pairs accumulated at the $Υ(4S)$ resonance with the Belle detector at the KEKB asymmetric-energy $e^+e^-$ collider. As the result of an unbinned maximum likelihood fit to the selected candidates, the mixing-induced and direct $CP$ violation parameters, $ϕ^{\rm eff}_1$ and ${\cal A}_{CP}$ are obtained for $B^0 \to ϕ(1020) K^0_S$, $B^0 \to f_0(980) K^0_S$ and other $B^0 \to K^+ K^- K^0_S$ decays. We find four solutions that describe the data. There are \{eqnarray*} ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (32.2 \pm 9.0 \pm 2.6 \pm 1.4)^{\circ}; ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (26.2 \pm 8.8 \pm 2.7 \pm 1.2)^{\circ};\\ ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (27.3 \pm 8.6 \pm 2.8 \pm 1.3)^{\circ}\; {\rm and}\\ ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (24.3 \pm 8.0 \pm 2.9 \pm 5.2)^{\circ}.{eqnarray*}\ The values for the $CP$ violating phase in $B^0\to ϕ(1020) K^0_S$ are similar but other properties of the Dalitz plot are quite different for the four solutions. These four solutions have consistent $ϕ^{\rm eff}_1$ values for all three $B$ meson decay channels and none of them deviates significantly from the values measured in $B \to (c\bar{c}) K^0$ decays with the currently available statistics. In addition, we find no significant direct $CP$ violation.

hep-ex↗

First Measurement of Inclusive B -> X_s eta Decays

We report a first measurement of inclusive B -> X_s eta decays, where X_s is a charmless state with unit strangeness. The measurement is based on a pseudo-inclusive reconstruction technique and uses a sample of 657 x 10^6 BB-bar pairs accumulated with the Belle detector at the KEKB e^+e^- collider. For M_{X_s} < 2.6 GeV/c^2, we measure a branching fraction of (26.1 +/- 3.0 (stat) +1.9 -2.1 (syst) +4.0 -7.1 (model)) x 10^-5 and a direct CP asymmetry of A_{CP} = -0.13 +/- 0.04 +0.02 -0.03. Over half of the signal occurs in the range M_{X_s} > 1.8 GeV/c^2.

hep-ex↗

Time and Amplitude of Afterpulse Measured with a Large Size Photomultiplier Tube

We have studied the afterpulse of a hemispherical photomultiplier tube for an upcoming reactor neutrino experiment. The timing, the amplitude, and the rate of the afterpulse for a 10 inch photomultiplier tube were measured with a 400 MHz FADC up to 16 \ms time window after the initial signal generated by an LED light pulse. The time and amplitude correlation of the afterpulse shows several distinctive groups. We describe the dependencies of the afterpulse on the applied high voltage and the amplitude of the main light pulse. The present data could shed light upon the general mechanism of the afterpulse.

physics.ins-det↗

Approximate and pseudo-amenability of various classes of Banach algebras

We continue the investigation of notions of approximate amenability that were introduced in work of the second and third authors. It is shown that every boundedly approximately contractible Banach algebra has a bounded approximate identity. Among our other results, it is shown that the Fourier algebra of the free group on two generators is not approximately amenable. Further examples are obtained of ${\ell}^1$-semigroup algebras which are approximately amenable but not amenable; using these, we show that bounded approximate amenability need not imply sequential approximate amenability. Results are also given for Segal subalgebras of $L^1(G)$, where $G$ is a locally compact group, and the algebras $PF_p(Γ)$ of $p$-pseudofunctions on a discrete group $Γ$ (of which the reduced $C^*$-algebra is a special case).

math.FA↗

GATE : a simulation toolkit for PET and SPECT

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/.

physics.med-ph↗

X-ray resonant magnetic scattering from structurally and magnetically rough interfaces in multilayered systems I. Specular reflectivity

The theoretical formulation of x-ray resonant magnetic scattering from rough surfaces and interfaces is given for specular reflectivity. A general expression is derived for both structurally and magnetically rough interfaces in the distorted-wave Born approximation (DWBA) as the framework of the theory. For this purpose, we have defined a ``structural'' and a ``magnetic'' interface to represent the actual interfaces. A generalization of the well-known Nevot-Croce formula for specular reflectivity is obtained for the case of a single rough magnetic interface using the self-consistent method. Finally, the results are generalized to the case of multiple interfaces, as in the case of thin films or multilayers. Theoretical calculations for each of the cases are illustrated with numerical examples and compared with experimental results of magnetic reflectivity from a Gd/Fe multilayer.

cond-mat.mtrl-sci↗

Lambda Hyperons in 2 A*GeV Ni + Cu Collisions

A sample of Lambda's produced in 2 A*GeV Ni + Cu collisions has been obtained with the EOS Time Projection Chamber at the Bevalac. Low background in the invariant mass distribution allows for the unambiguous demonstration of Lambda directed flow. The transverse mass spectrum at mid-rapidity has the characteristic shoulder-arm shape of particles undergoing radial transverse expansion. A linear dependence of Lambda multiplicity on impact parameter is observed, from which a total Lambda + Sigma^0 production cross section of $112 +/- 24 mb is deduced. Detailed comparisons with the ARC and RVUU models are made.

nucl-ex↗

The Evolution of Nuclear Multifragmentation in the Temperature-Density Plane

The mean transverse kinetic energies of the fragments formed in the interaction of 1 A GeV Au+C have been determined. An energy balance argument indicates the presence of a collective energy which increases in magnitude with increasing multiplicity and accounts for nearly half of the measured mean transverse kinetic energy. The radial flow velocity associated with the collective energy yields estimates for the time required to expand to the freeze-out volume. Isentropic trajectories in the temperature-density plane are shown for the expansion and indicate that the system goes through the critical region at the same multiplicities as deduced from a statistical analysis. Here, the expansion time is approximately 70 fm/c.

nucl-ex↗

Radial Flow in Au+Au Collisions at E=0.25-1.15 A GeV

A systematic study of energy spectra for light particles emitted at midrapidity from Au+Au collisions at E=0.25-1.15 A GeV reveals a significant non-thermal component consistent with a collective radial flow. This component is evaluated as a function of bombarding energy and event centrality. Comparisons to Quantum Molecular Dynamics (QMD) and Boltzmann-Uehling-Uhlenbeck (BUU) models are made for different equations of state.

nucl-ex↗