SearcharxivSearch

arXiv subjects

Y. Hino

Publications and source records attributed to Y. Hino.

At least 19 recordsLinked to original sources

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex

First results from the search for an excess of $\barν_{e}$ events in JSNS$^2$

The JSNS$^2$ (J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source) experiment at the Material and Life Science Facility (MLF) of J-PARC is designed to directly test an excess on $\barν_{e}$ events which was indicated by LSND (Liquid Scintillator Neutrino Detector). The combination of a short-pulsed proton beam and a gadolinium-loaded liquid scintillator provides an excellent signal-to-noise ratio. In this article, we report the first results of a direct test based on data collected in 2022. After applying all event selection criteria, two events are observed, consistent with the expected background of 2.3$\pm$0.4 events. No excess of $\barν_e$ events are seen in this report, however the expected number of events due to LSND anomaly is 1.1$\pm$0.5, thus this result is not yet conclusive. Data taking has been ongoing since 2021 and will continue in future runs. In addition, a new far detector has recently been constructed for the second phase experiment, JSNS$^2$-II, marking an important milestone toward forthcoming measurements.

hep-ex

A simulation model investigation of neutron-oxygen inelastic scattering and subsequent nucleus deexcitation based on experimental data

The nuclear interaction model plays an essential role in understanding neutrino-nucleus interactions in large-scale neutrino detectors. For example, in the Super-Kamiokande experiment, systematic uncertainties regarding atmospheric neutrino interactions on oxygen limit the sensitivity to some physics studies, such as the diffuse supernova neutrino background search. Reduction of such uncertainties necessitates an accurate modeling of nuclear reactions and subsequent nuclear deexcitation. For this purpose, a detailed study was performed by comparing various combinations of simulation models with the newly released neutron experimental data. From this study, it is found that the combination of INCL++ and NucDeEx implemented in a Geant4-based simulation shows a better agreement with the experimental data. The presented result will be referred to improve the future physics studies at neutrino detectors, including the current focus of Super-Kamiokande.

hep-ex

First measurement of neutron capture multiplicity in neutrino-oxygen neutral-current quasi-elastic-like interactions using an accelerator neutrino beam

We report the first measurement of neutron capture multiplicity in neutrino-oxygen neutral-current quasi-elastic-like interactions at the gadolinium-loaded Super-Kamiokande detector using the T2K neutrino beam, which has a peak energy of about 0.6 GeV. A total of 30 neutral-current quasi-elastic-like event candidates were selected from T2K data corresponding to an exposure of $1.76\times10^{20}$ protons on target. The $γ$ ray signals resulting from neutron captures were identified using a neural network. The flux-averaged mean neutron capture multiplicity was measured to be $1.37\pm0.33\text{ (stat.)}$$^{+0.17}_{-0.27}\text{ (syst.)}$, which is compatible within $2.3\,σ$ than predictions obtained using our nominal simulation. We discuss potential sources of systematic uncertainty in the prediction and demonstrate that a significant portion of this discrepancy arises from the modeling of hadron-nucleus interactions in the detector medium.

hep-ex

Development of the Beam Monitor Detectors for the Low-E Beamline at the CERN SPS H2 Line

A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the simultaneous readout of all strips of the X-Y detector was evaluated, in addition to the detection efficiency being assessed through coincidences with the trigger scintillators. The results demonstrated the successful acquisition of data with full strip readout and the reconstruction of the two-dimensional beam profile. Furthermore, we are contemplating the incorporation of GAGG crystals, an inorganic scintillator characterized by a high light yield ($\sim$$5 \times 10^{4}$ photons/MeV) and a brief time constant ($\sim$60 ns), within the newly developed time-of-flight detector. We assessed the resolution of time-of-flight based on the data, with the objective of achieving the required performance benchmarks through future improvements to the time-of-tlight detector.

physics.ins-det

First Measurement of Missing Energy Due to Nuclear Effects in Monoenergetic Neutrino Charged Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from $K^+ \rightarrow μ^+ ν_μ$ decay at rest ($E_{ν_μ}=235.5$ MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly $ν_μn \rightarrow μ^- p$ or $ν_μ$$^{12}\mathrm{C}$ $\rightarrow μ^-$$^{12}\mathrm{N}$, we define the missing energy as the energy transferred to the nucleus ($ω$) minus the kinetic energy of the outgoing proton(s), $E_{m} \equivω-\sum T_p$, and relate this to visible energy in the detector, $E_{m}=E_{ν_μ} (235.5 \mathrm{MeV})-m_μ(105.7 \mathrm{MeV}) + [m_n-m_p (1.3 \mathrm{MeV})] - E_{\mathrm{vis}}$. The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g. nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a $(77\pm3)$% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements,and Type-II supernova studies.

hep-ex

Modification on thermal motion in Geant4 for neutron capture simulation in Gadolinium loaded water

Neutron tagging is a fundamental technique for electron anti-neutrino detection via the inverse beta decay channel. A reported discrepancy in neutron detection efficiency between observational data and simulation predictions prompted an investigation into neutron capture modeling in Geant4. The study revealed that an overestimation of the thermal motion of hydrogen atoms in Geant4 impacts the fraction of captured nuclei. By manually modifying the Geant4 implementation, the simulation results align with calculations based on evaluated nuclear data and show good agreement with observables derived from the SK-Gd data.

hep-ex

Measurement of $γ$-rays generated by neutron interaction with ${}^{16}$O at 30 MeV and 250 MeV

Deep understanding of $γ$-ray production from the fast neutron reaction in water is crucial for various physics studies at large-scale water Cherenkov detectors. We performed test experiments using quasi-mono energetic neutron beams ($E_n = 30$ and 250~MeV) at Osaka University's Research Center for Nuclear Physics to measure $γ$-rays originating from the neutron-oxygen reaction with a high-purity germanium detector. Multiple $γ$-ray peaks which are expected to be from excited nuclei after the neutron-oxygen reaction were successfully observed. We measured the neutron beam flux by using a liquid scintillator for the cross section measurement. With a spectral fitting analysis based on the tailored $γ$-ray signal and background templates, we measured cross sections for each observed $γ$-ray component. The results will be useful to validate neutron models employed in the on-going and future water Cherenkov experiments.

nucl-ex

Rapid Analysis of $\mathrm{^{226}Ra}$ in Ultrapure Gadolinium Sulfate Octahydrate

Numerous particle physics experiments utilize gadolinium (Gd), a rare earth element with the most significant neutron capture cross-section among all elements, to detect anti-neutrinos via inverse beta-decays or to remove neutron-induced background events. For example, to load Gd into water Cherenkov detectors, $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$ is dissolved and rare event search experiments are required to screen for radioactive impurities in $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$ before dissolution. This study developed a new method to rapidly measure the radium-226($\mathrm{^{226}Ra}$) concentration in $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$. This method requires only three days to measure a batch of samples, as opposed to the usual method using high-purity germanium detectors, which takes approximately 20 days after arrival. The detection limit for the measurement of $\mathrm{^{226}Ra}$ is 0.32 mBq/kg. This method has been already used for $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$ screening at the Super-Kamiokande Gd(SK-Gd) project, and it can be applied to future experiments.

physics.ins-det

Conceptual Design Report of DaRveX: Decay at Rest $ν_e$ + Lead Cross Section Measurement at J-PARC MLF

DaRveX stands for "Decay at Rest $ν_e$-Pb cross (X) section measurement". So far, there has not been good target to detect low energy $ν_e$. Lead is expected to be an excellent $ν_e$ target because the cross section is expected to be very large and the delayed coincidence technique can be used using final state neutron(s). However, the cross section have not been measured yet. If it is measured, it opens a new window to the future neutrino research field, such as low energy $ν_e$ oscillation measurements, flavor specific detection of the supernova explosion $ν_e$ and understanding of $ν_e$-nucleus interactions. This report explains a conceptual design of DaRveX experiment, which measures cross section of $ν_e$+Pb charged current interaction, $ν_e$(E~30MeV)+Pb $\to$ $e^-$+$xn$+Bi; ($x$=1 or 2), using $ν_e$ from $μ^+$ decay at rest at J-PARC MLF. The energy and direction of the final state $e^-$ will be measured by using 1-ton scale lead-scintillator sandwich detector. With two years of data taking, the cross section is expected to be measured with 20% of precision.

hep-ex

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\barν_μ \to \barν_{e}$ appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the $\barν_{e}$ signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS$^2$ experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

hep-ex

The JSNS^2 Detector

The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.

physics.ins-det

Slow control and monitoring system at the JSNS$^{2}$

The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage (HV) of the photomultiplier tubes (PMTs), the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in June 2020. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

physics.ins-det

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $Δm^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $Δm^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex

The JSNS$^{2}$ data acquisition system

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate $γ$-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with the flash analog-to-digital converters. We present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

physics.ins-det

Performance of PMTs for the JSNS2 experiment

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24\,m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate $γ$-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS$^{2}$ did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS$^{2}$ experiment, and 120 PMTs were installed in the detector.

physics.ins-det

Production and optical properties of liquid scintillator for the JSNS$^{2}$ experiment

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment will search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS$^{2}$ inner detector will be filled with 17 tons of gadolinium-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate $γ$-catcher and outer veto volumes. JSNS$^{2}$ has chosen Linear Alkyl Benzene (LAB) as an organic solvent because of its chemical properties. The unloaded LS was produced at a refurbished facility, originally used for scintillator production by the RENO experiment. JSNS$^{2}$ plans to use ISO tanks for the storage and transportation of the LS. In this paper, we describe the LS production, and present measurements of its optical properties and long term stability. Our measurements show that storing the LS in ISO tanks does not result in degradation of its optical properties.

physics.ins-det