Searcharxiv⌕ Search

arXiv subjects

Y. Honda

Publications and source records attributed to Y. Honda.

29 records · Page 2Linked to original sources

Monochromaticity of coherent Smith-Purcell radiation from finite size grating

Investigation of coherent Smith-Purcell Radiation (SPR) spectral characteristics was performed both experimentally and by numerical simulation. The measurement of SPR spectral line shapes of different diffraction orders was carried out at KEK LUCX facility. A pair of room-temperature Schottky barrier diode (SBD) detectors with sensitivity bands of $60-90$~GHz and $320-460$~GHz was used in the measurements. Reasonable agreement of experimental results and simulations performed with CST Studio Suite justifies the use of different narrow-band SBD detectors to investigate different SPR diffraction orders. It was shown that monochromaticity of the SPR spectral lines increases with diffraction order. The comparison of coherent transition radiation and coherent SPR intensities in sub-THz frequency range showed that the brightnesses of both radiation mechanisms were comparable. A fine tuning feasibility of the SPR spectral lines is discussed.

physics.acc-ph↗

An event mixing technique for Bose-Einstein correlations of two pions in photoproduction around 1 GeV

We have developed an event mixing technique to observe Bose-Einstein correlations (BEC) between two identical neutral pions produced in photo-induced reactions in the non-perturbative QCD energy region. It is found that the missing-mass consistency cut and the pion-energy cut are essential for the event mixing method to effectively extract BEC observables. A Monte Carlo (MC) simulation is used to validate these constraints and confirms the efficiency of this method. Our work paves the way for similar BEC studies at lower energies where the multiplicity of emitted bosons is limited.

nucl-ex↗

Feedback-free optical cavity with self-resonating mechanism

We demonstrated the operation of a high finesse optical cavity without utilizing an active feedback system to stabilize the resonance. The effective finesse, which is a finesse including the overall system performance, of the cavity was measured to be $394,000 \pm 10,000$, and the laser power stored in the cavity was $2.52 \pm 0.13$ kW, which is approximately 187,000 times greater than the incident power to the cavity. The stored power was stabilized with a fluctuation of $1.7 \%$, and we confirmed continuous cavity operation for more than two hours. This result has the potential to trigger an innovative evolution for applications that use optical resonant cavities such as compact photon sources with laser-Compton scattering or cavity enhanced absorption spectroscopy.

physics.optics↗

Principal Component Analysis of Cavity Beam Position Monitor Signals

Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied to digitised signals obtained from a cavity beam position monitor (CBPM) system on the example of a 3-cavity test system installed at the Accelerator Test Facility 2 (ATF2) at KEK in Japan. We demonstrate that the PCA based method can be used to extract beam position information, and matches conventional techniques in terms of performance, while requiring considerably less settings and data for calibration.

physics.acc-ph↗

Cavity beam position monitor system for the Accelerator Test Facility 2

The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1 m for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

physics.acc-ph↗

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

physics.acc-ph↗

Production of gamma rays by pulsed laser beam Compton scattering off GeV-electrons using a non-planar four-mirror optical cavity

As part of the positron source R&D for future $e^+-e^-$ colliders and Compton based compact light sources, a high finesse non-planar four-mirror Fabry-Perot cavity has recently been installed at the ATF (KEK, Tsukuba, Japan). The first measurements of the gamma ray flux produced with a such cavity using a pulsed laser is presented here. We demonstrate the production of a flux of 2.7 $\pm$ 0.2 gamma rays per bunch crossing ($\sim3\times10^6$ gammas per second) during the commissioning.

physics.acc-ph↗

High flux polarized gamma rays production: first measurements with a four-mirror cavity at the ATF

The next generation of e+/e- colliders will require a very intense flux of gamma rays to allow high current polarized positrons to be produced. This can be achieved by converting polarized high energy photons in polarized pairs into a target. In that context, an optical system consisting of a laser and a four-mirror passive Fabry-Perot cavity has recently been installed at the Accelerator Test Facility (ATF) at KEK to produce a high flux of polarized gamma rays by inverse Compton scattering. In this contribution, we describe the experimental system and present preliminary results. An ultra-stable four-mirror non planar geometry has been implemented to ensure the polarization of the gamma rays produced. A fiber amplifier is used to inject about 10W in the high finesse cavity with a gain of 1000. A digital feedback system is used to keep the cavity at the length required for the optimal power enhancement. Preliminary measurements show that a flux of about $4\times10^6 γ$/s with an average energy of about 24 MeV was generated. Several upgrades currently in progress are also described.

physics.acc-ph↗

Suppression of superconductivity by non-magnetic disorder in organic superconductor $κ$-(BEDT-TTF)$_{2}$Cu(NCS)$_{2}$

The suppression of superconductivity by nonmagnetic disorder is investigated systematically in the organic superconductor $κ$-(BEDT-TTF)$_2$Cu(NCS)$_2$. We introduce a nonmagnetic disorder arising from molecule substitution in part with deuterated BEDT-TTF or BMDT-TTF for BEDT-TTF molecules and molecular defects introduced by X-ray irradiation. A quantitative evaluation of the scattering time $τ_{\rm dHvA}$ is carried out by de Haas-van Alphen (dHvA) effect measurement. A large reduction in $T_{\rm c}$ with a linear dependence on $1/τ_{\rm dHvA}$ is found in the small-disorder region below $1/τ_{\rm dHvA} \simeq$ 1 $\times$ 10$^{12}$ s$^{-1}$ in both the BMDT-TTF molecule-substituted and X-ray-irradiated samples. The observed linear relation between $T_{\rm c}$ and $1/τ_{\rm dHvA}$ is in agreement with the Abrikosov-Gorkov (AG) formula, at least in the small-disorder region. This observation is reasonably consistent with the unconventional superconductivity proposed thus far for the present organic superconductor. A deviation from the AG formula, however, is observed in the large-disorder region above $1/τ_{\rm dHvA} \simeq$ 1 $\times$ 10$^{12}$ s$^{-1}$, which reproduces the previous transport study (J. G. Analytis {\it et al.}: Phys. Rev. Lett. {\bf 96} (2006) 177002). We present some interpretations of this deviation from the viewpoints of superconductivity and the inherent difficulties in the evaluation of scattering time.

cond-mat.supr-con↗

R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor)

Shintake monitor is a nanometer-scale electron beam size monitor. It probes a electron beam by an interference fringe pattern formed by split laser beams. Minimum measurable beam size by this method is less than 1/10 of laser wavelength. In ATF2, Shintake monitor will be used for the IP beam size monitor to measure 37 nm (design) beam size. Development status of the Shintake monitor, including fringe phase monitoring and stabilization, gamma detector and collimators, is described. In addition, we discuss the beam size measurement by Shintake monitor in ILC.

physics.acc-ph↗

Design of a Polarised Positron Source Based on Laser Compton Scattering

We describe a scheme for producing polarised positrons at the ILC from polarised X-rays created by Compton scattering of a few-GeV electron beam off a CO2 or YAG laser. This scheme is very energy effective using high finesse laser cavities in conjunction with an electron storage ring.

physics.acc-ph↗