Development and Quality Control of PMT Modules for the Large-Sized Telescopes of the Cherenkov Telescope Array Observatory

The camera of the Large-Sized Telescopes (LSTs) of the Cherenkov Telescope Array Observatory (CTAO) consists of 1855 pixels that are grouped into 265 high-performance photomultiplier tube (PMT) modules. Each module comprises a seven-light-guide plate, seven PMT units, a slow control board, and a readout board with a trigger board. %In this paper we describe The requirements for the PMT modules include various aspects, such as photon detection efficiency, dynamic range, buffer depth, and test pulse functionality. We have developed a high-performance PMT module that fulfills all these requirements. Mass-production and quality control (QC) of modules for all four LSTs of the northern CTAO have been completed. Here we report on the technical details of each element of the module and its performance, together with the methods and results of QC measurements.

astro-ph.IM

Rapid Analysis of $\mathrm{^{226}Ra}$ in Ultrapure Gadolinium Sulfate Octahydrate

Numerous particle physics experiments utilize gadolinium (Gd), a rare earth element with the most significant neutron capture cross-section among all elements, to detect anti-neutrinos via inverse beta-decays or to remove neutron-induced background events. For example, to load Gd into water Cherenkov detectors, $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$ is dissolved and rare event search experiments are required to screen for radioactive impurities in $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$ before dissolution. This study developed a new method to rapidly measure the radium-226($\mathrm{^{226}Ra}$) concentration in $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$. This method requires only three days to measure a batch of samples, as opposed to the usual method using high-purity germanium detectors, which takes approximately 20 days after arrival. The detection limit for the measurement of $\mathrm{^{226}Ra}$ is 0.32 mBq/kg. This method has been already used for $\mathrm{{Gd_{2}(SO_{4})_{3}\cdot 8H_{2}O}}$ screening at the Super-Kamiokande Gd(SK-Gd) project, and it can be applied to future experiments.

physics.ins-det

Commissioning of the camera of the first Large Size Telescope of the Cherenkov Telescope Array

The first Large Size Telescope (LST-1) of the Cherenkov Telescope Array has been operational since October 2018 at La Palma, Spain. We report on the results obtained during the camera commissioning. The noise level of the readout is determined as a 0.2 p.e. level. The gain of PMTs are well equalized within 2\% variation, using the calibration flash system. The effect of the night sky background on the signal readout noise as well as the PMT gain estimation are also well evaluated. Trigger thresholds are optimized for the lowest possible gamma-ray energy threshold and the trigger distribution synchronization has been achieved within 1~ns precision. Automatic rate control realizes the stable observation with 1.5\% rate variation over 3 hours. The performance of the novel DAQ system demonstrates a less than 10\% dead time for 15 kHz trigger rate even with sophisticated online data correction.

astro-ph.IM

A Technique for Estimating the Absolute Gain of a Photomultiplier Tube

Detection of low-intensity light relies on the conversion of photons to photoelectrons, which are then multiplied and detected as an electrical signal. To measure the actual intensity of the light, one must know the factor by which the photoelectrons have been multiplied. To obtain this amplification factor, we have developed a procedure for estimating precisely the signal caused by a single photoelectron. The method utilizes the fact that the photoelectrons conform to a Poisson distribution. The average signal produced by a single photoelectron can then be estimated from the number of noise events, without requiring analysis of the distribution of the signal produced by a single photoelectron. The signal produced by one or more photoelectrons can be estimated experimentally without any assumptions. This technique, and an example of the analysis of a signal from a photomultiplier tube, are described in this study.

astro-ph.IM