SearcharxivSearch

arXiv subjects

Y. Jeong

Publications and source records attributed to Y. Jeong.

4 recordsLinked to original sources

Quantitative perfusion and water transport time model from multi b-value diffusion magnetic resonance imaging validated against neutron capture microspheres

Intravoxel Incoherent Motion (IVIM) is a non-contrast magnetic resonance imaging diffusion-based scan that uses a multitude of b-values to measure various speeds of molecular perfusion and diffusion, sidestepping inaccuracy of arterial input functions or bolus kinetics in quantitative imaging. We test a new method of IVIM quantification and compare our values to reference standard neutron capture microspheres across normocapnia, CO2 induced hypercapnia, and middle cerebral artery occlusion in a controlled animal model. Perfusion quantification in ml/100g/min compared to microsphere perfusion uses the 3D gaussian probability distribution and defined water transport time as when 50% of the molecules remain in the tissue of interest. Perfusion, water transport time, and infarct volume was compared to reference standards. Simulations were studied to suppress non-specific cerebrospinal fluid (CSF). Linear regression analysis of quantitative perfusion returned correlation (slope = .55, intercept = 52.5, $R^2$= .64). Linear regression for water transport time asymmetry in infarcted tissue was excellent (slope = .59, intercept = .3, $R^2$ = .93). Strong linear agreement also was found for infarct volume (slope = 1.01, $R^2$= .79). Simulation of CSF suppression via inversion recovery returned blood signal reduced by 82% from combined T1 and T2 effects. Intra-physiologic state comparison of perfusion shows potential partial volume effects which require further study especially in disease states. The accuracy and sensitivity of IVIM provides evidence that observed signal changes reflect cytotoxic edema and tissue perfusion. Partial volume contamination of CSF may be better removed during post-processing rather than with inversion recovery to avoid artificial loss of blood signal.

physics.med-ph

Pulse shape discrimination using a convolutional neural network for organic liquid scintillator signals

A convolutional neural network (CNN) architecture is developed to improve the pulse shape discrimination (PSD) power of the gadolinium-loaded organic liquid scintillation detector to reduce the fast neutron background in the inverse beta decay candidate events of the NEOS-II data. A power spectrum of an event is constructed using a fast Fourier transform of the time domain raw waveforms and put into CNN. An early data set is evaluated by CNN after it is trained using low energy $β$ and $α$ events. The signal-to-background ratio averaged over 1-10 MeV visible energy range is enhanced by more than 20% in the result of the CNN method compared to that of an existing conventional PSD method, and the improvement is even higher in the low energy region.

physics.ins-det

Radon concentration variations at the Yangyang underground laboratory

The concentration of radon in the air has been measured in the 700 m-deep Yangyang underground laboratory between October 2004 and May 2022. The average concentrations in two experimental areas, called A6 and A5, were measured to be 53.4$\pm$0.2 Bq/m3 and 33.5$\pm$0.1 Bq/m3, respectively. The lower value in the A5 area reflects the presence of better temperature control and ventilation. The radon concentrations sampled within the two A5 experimental rooms' air are found to be correlated to the local surface temperature outside of the rooms, with correlation coefficients r = 0.22 and r = 0.70. Therefore, the radon concentrations display a seasonal variation, because the local temperature driven by the overground season influences air ventilation in the experimental areas. A fit on the annual residual concentrations finds that the amplitude occurs each year on August, 31$\pm$6 days.

physics.ins-det

Pulse Shape Discrimination of Fast Neutron Background using Convolutional Neural Network for NEOS II

Pulse shape discrimination plays a key role in improving the signal-to-background ratio in NEOS analysis by removing fast neutrons. Identifying particles by looking at the tail of the waveform has been an effective and plausible approach for pulse shape discrimination, but has the limitation in sorting low energy particles. As a good alternative, the convolutional neural network can scan the entire waveform as they are to recognize the characteristics of the pulse and perform shape classification of NEOS data. This network provides a powerful identification tool for all energy ranges and helps to search unprecedented phenomena of low-energy, a few MeV or less, neutrinos.

physics.ins-det