Searcharxiv⌕ Search

arXiv subjects

Y. Lan

Publications and source records attributed to Y. Lan.

45 records · Page 3Linked to original sources

Characterization of an Ionization Readout Tile for nEXO

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.

physics.ins-det↗

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

A precision mass investigation of the neutron-rich titanium isotopes $^{51-55}$Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the $N=32$ shell closure and the overall uncertainties of the $^{52-55}$Ti mass values were significantly reduced. Our results confirm the existence of a weak shell effect at $N=32$, establishing the abrupt onset of this shell closure. Our data were compared with state-of-the-art \textit{ab-initio} shell model calculations which, despite very successfully describing where the $N=32$ shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements also represent the first scientific results of TITAN using the newly commissioned Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS), substantiated by independent measurements from TITAN's Penning trap mass spectrometer.

nucl-ex↗

High-precision $Q_{EC}$-value measurement of the superallowed $β^+$ emitter $^{22}$Mg and an evaluation of the $A=22$ isobaric triplet

A direct $Q_{EC}$-value measurement of the superallowed $β^+$ emitter $^{22}$Mg was performed using TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The direct ground-state to ground-state atomic mass difference between $^{22}$Mg and $^{22}$Na was determined to be $Q_{EC}=4781.40(22)$~keV, representing the most precise single measurement of this quantity to date. In a continued push towards calculating superallowed isospin-symmetry-breaking (ISB) corrections from first principles, ab-initio shell-model calculations of the $A=22$ IMME are also presented for the first time using the valence-space in-medium similarity renormalization group formalism. With particular starting two- and three-nucleon forces, this approach demonstrates a level of agreement with the experimental data that suggests reliable ab-initio calculations of superallowed ISB corrections are now possible.

nucl-ex↗

Searches for Double Beta Decay of $^{134}$Xe with EXO-200

Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derived, with corresponding half-life sensitivities of $1.2\cdot10^{21}\text{ yr}$ and $1.9\cdot10^{23}\text{ yr}$. These limits exceed those in the literature for $^{134}$Xe, improving by factors of nearly $10^{5}$ and 2 for the two antineutrino and neutrinoless modes, respectively.

hep-ex↗

Precision mass measurements of $^{125-127}$Cd isotopes and isomers approaching the $N=82$ closed shell

We present the results of precision mass measurements of neutron-rich cadmium isotopes. These nuclei approach the $N=82$ closed neutron shell and are important to nuclear structure as they lie near doubly-magic $^{132}$Sn on the chart of nuclides. Of particular note is the clear identification of the ground state mass in $^{127}$Cd along with the isomeric state. We show that the ground state identified in a previous mass measurement which dominates the mass value in the Atomic Mass Evaluation is an isomeric state. In addition to $^{127/m}$Cd, we present other cadmium masses measured ($^{125/m}$Cd and $^{126}$Cd) in a recent TITAN experiment at TRIUMF. Finally, we compare our measurements to new \emph{ab initio} shell-model calculations and comment on the state of the field in the $N=82$ region.

nucl-ex↗

Trace radioactive impurities in final construction materials for EXO-200

We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.

physics.ins-det↗

Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At the operating field of 380~V/cm EXO-200 measures a drift velocity of 1.705$_{-0.010}^{+0.014}$~mm/$μ$s and a transverse diffusion coefficient of 55$\pm$4~cm$^2$/s.

physics.ins-det↗

Determination of Thermal History by Photoluminescence of Core-shelled Quantum Dots Going Through Heating Events

A kind of novel thermal history nanosensors were theoretically designed and experimentally demonstrated to permanently record thermal events. The photoluminescence spectrum of core-shelled quantum dots CdSe/ZnS irreversibly shifted with heating histories (temperature and duration) of thermal events. The induced photoluminescence shift of the quantum dots CdSe/ZnS was employed to permanently record thermal histories. We further modeled a kind of thermal history nanosensor based on the thermal induced phenomena of core-shelled quantum dots to permanently record thermal histories at microscale and demonstrated to reconstruct temperature and duration of heating events simultaneously from photoluminescence spectra of the quantum dots. The physical mechanism of the sensors was discussed.

cond-mat.mtrl-sci↗

Probing the magnetic ground state of the molecular Dysprosium triangle

We present zero field muon spin lattice relaxation measurements of a Dysprosium triangle molecular magnet. The local magnetic fields sensed by the implanted muons indicate the coexistence of static and dynamic internal magnetic fields below $T^* ~35$ K. Bulk magnetization and heat capacity measurements show no indication of magnetic ordering below this temperature. We attribute the static fields to the slow relaxation of the magnetization in the ground state of Dy3. The fluctuation time of the dynamic part of the field is estimated to be ~0.55 $μ$s at low temperatures

cond-mat.str-el↗