Searcharxiv⌕ Search

arXiv subjects

Y. Ma

Publications and source records attributed to Y. Ma.

At least 73 records · Page 4Linked to original sources

Cosmogenic background simulations for the DARWIN observatory at different underground locations

Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.

physics.ins-det↗

Featureless transmission spectra of 12 giant exoplanets observed by GTC/OSIRIS

Exoplanet atmospheres are the key to understanding the nature of exoplanets. To this end, transit spectrophotometry provides us opportunities to investigate the physical properties and chemical compositions of exoplanet atmospheres. We aim to detect potential atmospheric signatures in 12 gaseous giant exoplanets using transit spectrophotometry and we try to constrain their atmospheric properties. The targets of interest were observed using transit spectrophotometry with the GTC OSIRIS instrument. We estimated the transit parameters and obtained the optical transmission spectra of the target planets using a Bayesian framework. We analyzed the spectral features in the transmission spectra based on atmospheric retrievals. Most of the observed transmission spectra were found to be featureless, with only the spectrum of CoRoT-1b showing strong evidence for atmospheric features. However, in combination with the previously published near-infrared transmission spectrum, we found multiple interpretations for the atmosphere of CoRoT-1b due to the lack of decisive evidence for alkali metals or optical absorbers. Featureless spectra are not necessarily indicative of cloudy atmospheres if they poorly constrain the altitudes of cloud decks. Precise constraints on the models of hazes and clouds strongly depend on the significance of the observed spectral features. Further investigations on these exoplanets, especially CoRoT-1b, are required to confirm the properties of their atmospheres.

astro-ph.EP↗

Searching for Heavy Dark Matter near the Planck Mass with XENON1T

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This work places strong constraints on spin-independent interactions of dark matter particles with a mass between 1$\times$10$^{12}\,$GeV/c$^2$ and 2$\times$10$^{17}\,$GeV/c$^2$. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections for dark matter particles with masses close to the Planck scale.

hep-ex↗

First Observation of $Λπ^+$ and $Λπ^-$ Signals near the $\bar{K}N (I=1)$ Mass Threshold in $Λ_c^+\rightarrowΛπ^+π^+π^-$ Decay

Using the data sample of 980 fb$^{-1}$ collected with the Belle detector operating at the KEKB asymmetric-energy $e^+e^-$ collider, we present the results of an investigation of the $Λπ^+$ and $Λπ^-$ invariant mass distributions looking for substructure in the decay $Λ_c^+\rightarrowΛπ^+π^+π^-$. We find a significant signal in each mass dis\ tribution. When interpreted as resonances, we find for the $Λπ^+$ ($Λπ^-$) combination a mass of $1434.3 \pm 0.6 (\mathrm{stat}) \pm 0.9(\mathrm{syst})$ MeV/$c^2$ [$1438.5 \pm 0.9 (\mathrm{stat}) \pm 2.5(\mathrm{syst})$ MeV/$c^2$], an intrinsic width of $11.5 \pm 2.8 (\mathrm{stat}) \pm 5.3(\mathrm{syst})$ MeV/$c^2$ [$33.0 \pm 7.5 (\mathrm{stat}) \pm 23.6(\mathrm{syst})$ MeV/$c^2$] with a significance of 7.5$σ$ (6.2$σ$). As these two signals are very close to the $\bar{K}N$ threshold, we also investigate the possibility of a $\bar{K}N$ cusp, and find that \ we cannot discriminate between these two interpretations due to the limited size of the data sample.

hep-ex↗

Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.

physics.ins-det↗

Material radiopurity control in the XENONnT experiment

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

physics.ins-det↗

The Triggerless Data Acquisition System of the XENONnT Experiment

The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at $\times10$ and $\times0.5$ gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within $\mathcal{O}\left(10\text{ s}\right)$ for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed $\sim500$ MB/s during calibration. Livetime during normal operation exceeds $99\%$ and is $\sim90\%$ during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.

physics.ins-det↗

Characterisation of Laser Wakefield Acceleration Efficiency with Octave Spanning Near-IR Spectrum Measurements

We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximised at $19\pm3$\% by tuning of the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimisation of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.

physics.plasm-ph↗

Search for New Physics in Electronic Recoil Data from XENONnT

We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

hep-ex↗

An approximate likelihood for nuclear recoil searches with XENON1T data

The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 tonne-year exposure.

hep-ex↗

Pole position of $Λ(1405)$ measured in $d(K^-,n)πΣ$ reactions

We measured a set of $π^\pmΣ^\mp$, $π^0Σ^0$, and $π^-Σ^0$ invariant mass spectra below and above the $\bar{K}N$ mass threshold in $K^-$-induced reactions on deuteron. We deduced the $S$-wave $\bar{K}N\rightarrowπΣ$ and $\bar{K}N\rightarrow\bar{K}N$ scattering amplitudes in the isospin 0 channel in the framework of a $\bar{K}N$ and $πΣ$ coupled channel. We find that a resonance pole corresponding to $Λ(1405)$ is located at 1417.7$^{+6.0}_{-7.4}$(fitting errors)$^{+1.1}_{-1.0}$(systematic errors) + $[-26.1^{+6.0}_{-7.9}$(fitting errors)$^{+1.7}_{-2.0}$(systematic errors)]$i$ MeV/$c^2$, closer to the $\bar{K}N$ mass threshold than the value determined by the Particle Data Group.

nucl-ex↗

Double-Weak Decays of $^{124}$Xe and $^{136}$Xe in the XENON1T and XENONnT Experiments

We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a $0.87\;\text{kg}\times\text{yr}$ isotope exposure. The statistical significance of the signal is $7.0\,σ$. We use XENON1T data with $36.16\;\text{kg}\times\text{yr}$ of $^{136}$Xe exposure to search for $0νββ$. We find no evidence of a signal and set a lower limit on the half-life of $T_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to $0νββ$. Assuming a $275\;\text{kg}\times\text{yr}$ $^{136}$Xe exposure, the expected sensitivity is $T_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$, corresponding to an effective Majorana mass range of $\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2$.

hep-ex↗

Sustainable steel through hydrogen plasma reduction of iron ore: process, kinetics, microstructure, chemistry

Fe- and steelmaking is the largest single industrial CO2 emitter, accounting for 6.5% of all CO2 emissions on the planet. This fact challenges the current technologies to achieve carbon-lean steel production and to align with the requirement of a drastic reduction of 80% in all CO2 emissions by around 2050. Thus, alternative reduction technologies have to be implemented for extracting iron from its ores. The H-based direct reduction has been explored as a sustainable route to mitigate CO2 emissions, where the reduction kinetics of the intermediate oxide product FexO wustite into Fe is the rate-limiting step of the process. The total reaction has an endothermic net energy balance. Reduction based on a H plasma may offer an attractive alternative. Here, we present a study about the reduction of hematite using H plasma. The evolution of both, chemical composition and phase transformations was investigated in several intermediate states. We found that hematite reduction kinetics depends on the balance between the initial input mass and the arc power. For an optimized input mass-arc power ratio, complete reduction was obtained within 15 min of exposure to the H plasma. The wustite reduction is also the rate-limiting step towards complete reduction. Nonetheless, the reduction reaction is exothermic, and its rates are comparable with those found in H-based direct reduction. Chemical and microstructure analysis revealed that the gangue elements partition to the remaining oxide regions, probed by energy dispersive spectroscopy and atom probe tomography. Si-enrichment was observed in the interdendritic fayalite domains, at the wustite/Fe hetero-interfaces and in the primarily solidified oxide particles inside the Fe. With proceeding reduction, however, such elements are gradually removed from the samples so that the final iron product is nearly free of gangue-related impurities.

cond-mat.mtrl-sci↗

Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.

physics.ins-det↗

Recent results and future prospects of kaonic nuclei at J-PARC

$\bar K$-nuclear bound systems, kaonic nuclei, have been widely discussed as products of the strongly attractive $\bar K N$ interaction in $I = 0$ channels. Recently, we demonstrated that kaonic nuclei can be produced via in-flight $(K^-,N)$ reactions using the low-momentum DC kaon beam at the J-PARC E15 experiment. We observed the simplest kaonic nuclei, $K^-pp$, having a much deeper binding energy than normal nuclei. For further studies, we have proposed a series of experimental programs for the systematic investigation of light kaonic nuclei, from $\bar K N$ ($Λ(1405)$) to $\bar K NNNN$. In the new experiment approved as J-PARC E80, we will measure the $\bar K NNN$ ($A=3$) system as a first step toward a comprehensive study.

nucl-ex↗

Evidence for stellar contamination in the transmission spectra of HAT-P-12b

Transmission spectroscopy characterizes the wavelength dependence of transit depth, revealing atmospheric absorption features in planetary terminator regions. In this context, different optical transmission spectra of HAT-P-12b reported in previous studies exhibited discrepant atmospheric features (e.g., Rayleigh scattering, alkali absorption). We aim to understand the atmosphere of HAT-P-12b using two transit spectroscopic observations by the Gran Telescopio CANARIAS (GTC), and to search for evidence of stellar activity contaminating the transmission spectra, which might be the reason behind the discrepancies. We used Gaussian processes to account for systematic noise in the transit light curves and used nested sampling for Bayesian inferences. We performed joint atmospheric retrievals using the two transmission spectra obtained by GTC OSIRIS, as well as previously published results, coupled with stellar contamination corrections for different observations. The retrieved atmospheric model exhibits no alkali absorption signatures, but shows tentative molecular absorption features including $\rm H_2O$, $\rm CH_4$ and $\rm NH_3$. The joint retrieval of the combined additional public data analysis retrieves similar results, but with a higher metallicity. Based on Bayesian model comparison, the discrepancies of the transmission spectra of HAT-P-12b can be explained by the effect of different levels of unocculted stellar spots and faculae. In addition, we did not find strong evidence for a cloudy or hazy atmosphere from the joint analysis, which is inconsistent with prior studies based on the observations of Hubble Space Telescope.

astro-ph.EP↗

Quantum-enhanced radiometry via approximate quantum error correction

By exploiting the exotic quantum states of a probe, it is possible to realize efficient sensors that are attractive for practical metrology applications and fundamental studies. Similar to other quantum technologies, quantum sensing is suffering from noises and thus the experimental developments are hindered. Although theoretical schemes based on quantum error correction (QEC) have been proposed to combat noises, their demonstrations are prevented by the stringent experimental requirements, such as perfect quantum operations and the orthogonal condition between the sensing interaction Hamiltonian and the noise Lindbladians. Here, we report an experimental demonstration of a quantum enhancement in sensing with a bosonic probe with different encodings, by exploring the large Hilbert space of the bosonic mode and developing both the approximate QEC and the quantum jump tracking approaches. In a practical radiometry scenario, we attain a 5.3 dB enhancement of sensitivity, which reaches $9.1\times10^{-4}\,\mathrm{Hz}^{-1/2}$ when measuring the excitation population of a receiver mode. Our results demonstrate the potential of quantum sensing with near-term quantum technologies, not only shedding new light on the quantum advantage of sensing by revealing its difference from other quantum applications, but also stimulating further efforts on bosonic quantum technologies.

quant-ph↗

Search for Coherent Elastic Scattering of Solar $^8$B Neutrinos in the XENON1T Dark Matter Experiment

We report on a search for nuclear recoil signals from solar $^8$B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 keV to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant $^8$B neutrino-like excess is found in an exposure of 0.6 t $\times$ y. For the first time, we use the non-detection of solar neutrinos to constrain the light yield from 1-2 keV nuclear recoils in liquid xenon, as well as non-standard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 GeV/c$^2$ and 11 GeV/c$^2$ by as much as an order of magnitude.

hep-ex↗