SearcharxivSearch

arXiv subjects

Y. Meng

Publications and source records attributed to Y. Meng.

At least 19 recordsLinked to original sources

A Modern ConvNet for Solar Filament Detection

Automated solar filament detection using deep learning faces several challenges. Semantic segmentation of solar filaments is a complicated multiscale feature extraction task with long-tail distribution. Furthermore, a large-scale, highly complete, and finely detailed dataset has become mandatory for providing abundant information. To address these challenges, we present a series of machine learning approaches to develop a solar filament detection workflow that performs superbly. First, we manually annotated a small-scale solar filament dataset based on H$\alpha$ spectra called MHAS. Next, we developed the Multiscale ORiented DENdritic (MORDEN) model, a semantic segmentation model focusing on multiscale feature extraction. We also introduced the Dense Conditional Random Field (DenseCRF) and Density-Based Spatial Clustering of Applications with Noise (DBSCAN) methods for post-processing. Using the proposed workflow, we generated a large-scale, high-quality dataset called AHAS. Experimental results demonstrate that MORDEN outperforms several existing solar filament semantic segmentation models with open access. DenseCRF has been demonstrated to effectively capture fine edge details. We also evaluated the effects of data scaling and the reliability of DBSCAN and found that both approaches yield satisfactory performance. Multiple visualization results substantiate our quantitative findings. Our work provides a foundation for maximizing the potential of deep learning models for solar filament detection.

astro-ph.SR

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $\sigma = 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $\sigma \approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10M{\Omega} resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200k{\Omega}) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

The calibration house in JUNO

As an auxiliary system within the calibration system of the Jiangmen Underground Neutrino Observatory, a calibration house is designed to provide interfaces for connecting the central detector and accommodating various calibration sub-systems. Onsite installation has demonstrated that the calibration house interfaces are capable of effectively connecting to the central detector and supporting the installation of complex and sophisticated calibration sub-systems. Additionally, controlling the levels of radon and oxygen within the calibration house is critical. Radon can increase the experimental background, while oxygen can degrade the quality of the liquid scintillator. The oxygen concentration can be maintained at levels below 10 parts per million, and the radon concentration can be kept below 15 mBq/m$^{3}$. This paper will provide detailed information on the calibration house and its methods for radon and oxygen concentration control.

physics.ins-det

A Criterion for Magnetars Producing Giant Flares

In this work, the straight flux rope in the model of giant flares on magnetars (Meng et al. 2014) was replaced with a curved one and the equilibrium behavior of the flux rope was investigated. Two footpoints of the flux rope are anchored to the spherical surface of magnetar. The forces acting on the flux rope include magnetic tension, magnetic pressure, curvature force, gravity. The equilibrium in the flux rope, so as in the global configuration, is achieved as these forces offset each other. Changes in the background environment drive the configuration to evolve through a set of equilibria in a quasi-static fashion until the critical point is reached and the loss of equilibrium in the configuration occurs, invoking a giant flare. We establish a criterion to identify magnetars capable of producing giant flares. Among the four forces, the curvature force as well as the magnetic compression tend to expel the flue rope outward. In a given magnetic configuration, the curvature force and magnetic compression are proportional to the square of the current intensity of the flux rope, which is determined by the frozen-flux condition and background magnetic field strength. We find that only when $\eta = G M m / ({{{R^4}{B_0}^2}})< 0.48 $ is satisfied, the system reaches a critical point and potentially undergoes catastrophe. Here, $G, M, m, R$, and $B_{0}$ are the gravitational constant, the mass of neutron star, the mass of flux rope, the radius of neutron star, and the surface magnetic field strength of neutron star, respectively. The physical meaning of this criterion is that when $\eta \propto m / B_{0}^{2}$ is small enough, the curvature force and magnetic pressure can be sufficiently large to overcome gravitational confinement. This criterion establishes a basis for identifying magnetars capable of producing giant flares.

astro-ph.HE

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. The measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

physics.ins-det

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det

High-pressure Phase Transition of Olivine-type Mg$_2$GeO$_4$ to a Metastable Forsterite-III type Structure and their Equation of States

Germanates are often used as structural analogs of planetary silicates. We have explored the high-pressure phase relations in Mg$_2$GeO$_4$ using diamond anvil cell experiments combined with synchrotron x-ray diffraction and computations based on density functional theory. Upon room temperature compression, forsterite-type Mg$_2$GeO$_4$ remains stable up to 30 GPa. At higher pressures, a phase transition to a forsterite-III type (Cmc21) structure was observed, which remained stable to the peak pressure of 105 GPa. Using a 3rd order Birch Murnaghan fit to the experimental data, we obtained V0 = 305.1 (3) {\AA}3, K0 = 124.6 (14) GPa and K0' = 3.86 (fixed) for forsterite- and V0 = 263.5 (15) {\AA}3, K0 = 175 (7) GPa and K0' = 4.2 (fixed) for the forsterite-III type phase. The forsterite-III type structure was found to be metastable when compared to the stable assemblage of perovskite/post-perovskite + MgO, as observed during laser-heating experiments. Understanding the phase relations and physical properties of metastable phases is crucial for studying the mineralogy of impact sites, understanding metastable wedges in subducting slabs and interpreting the results of shock compression experiments.

physics.geo-ph

Measurement of the Gamma-Ray Energy Spectrum beyond 100 TeV from the HESS J1843$-$033 Region

HESS J1843$-$033 is a very-high-energy gamma-ray source whose origin remains unidentified. This work presents, for the first time, the energy spectrum of gamma rays beyond $100\, {\rm TeV}$ from the HESS J1843$-$033 region using the data recorded by the Tibet air shower array and its underground muon detector array. A gamma-ray source with an extension of $0.34^{\circ} \pm 0.12^{\circ}$ is successfully detected above $25\, {\rm TeV}$ at $(\alpha,\, \delta) = (281.09^{\circ}\pm 0.10^{\circ},\, -3.76^{\circ}\pm 0.09^{\circ})$ near HESS J1843$-$033 with a statistical significance of $6.2\, \sigma$, and the source is named TASG J1844$-$038. The position of TASG J1844$-$038 is consistent with those of HESS J1843$-$033, eHWC J1842$-$035, and LHAASO J1843$-$0338. The measured gamma-ray energy spectrum in $25\, {\rm TeV} < E < 130\, {\rm TeV}$ is described with ${\rm d}N/{\rm d}E = (9.70\pm 1.89)\times 10^{-16} (E/40\, {\rm TeV})^{-3.26\pm 0.30}\, {\rm TeV}^{-1} {\rm cm}^{-2} {\rm s}^{-1}$, and the spectral fit to the combined spectra of HESS J1843$-$033, LHAASO J1843$-$0338, and TASG J1844$-$038 implies the existence of a cutoff at $49.5\pm 9.0\, {\rm TeV}$. Associations of TASG J1844-038 with SNR G28.6$-$0.1 and PSR J1844-0346 are also discussed in detail for the first time.

astro-ph.HE

Observation of gamma rays up to 320 TeV from the middle-aged TeV pulsar wind nebula HESS J1849$-$000

Gamma rays from HESS J1849$-$000, a middle-aged TeV pulsar wind nebula (PWN), are observed by the Tibet air shower array and the muon detector array. The detection significance of gamma rays reaches $4.0\, \sigma$ and $4.4\, \sigma$ levels above 25 TeV and 100 TeV, respectively, in units of Gaussian standard deviation $\sigma$. The energy spectrum measured between $40\, {\rm TeV} < E < 320\, {\rm TeV}$ for the first time is described with a simple power-law function of ${\rm d}N/{\rm d}E = (2.86 \pm 1.44) \times 10^{-16}(E/40\, {\rm TeV})^{-2.24 \pm 0.41}\, {\rm TeV}^{-1}\, {\rm cm}^{-2}\, {\rm s}^{-1}$. The gamma-ray energy spectrum from the sub-TeV ($E < 1\, {\rm TeV}$) to sub-PeV ($100\, {\rm TeV} < E < 1\, {\rm PeV}$) ranges including the results of previous studies can be modeled with the leptonic scenario, inverse Compton scattering by high-energy electrons accelerated by the PWN of PSR J1849$-$0001. On the other hand, the gamma-ray energy spectrum can also be modeled with the hadronic scenario in which gamma rays are generated from the decay of neutral pions produced by collisions between accelerated cosmic-ray protons and the ambient molecular cloud found in the gamma-ray emitting region. The cutoff energy of cosmic-ray protons $E_{\rm p\, cut}$, cut is estimated at ${\rm log}_{10}(E_{\rm p,\, cut}/{\rm TeV}) = 3.73^{+2.98}_{-0.66}$, suggesting that protons are accelerated up to the PeV energy range. Our study thus proposes that HESS J1849$-$000 should be further investigated as a new candidate for a Galactic PeV cosmic-ray accelerator, PeVatron.

astro-ph.HE

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det

Generation of Spin Defects by Ion Implantation in Hexagonal Boron Nitride

Optically addressable spin defects in wide-bandage semiconductors as promising systems for quantum information and sensing applications have attracted more and more attention recently. Spin defects in two-dimensional materials are supposed to have unique superiority in quantum sensing since their atomatic thickness. Here, we demonstrate that the negatively boron charged vacancy (V$ _\text{B}^{-} $) with good spin properties in hexagonal boron nitride can be generated by ion implantation. We carry out optically detected magnetic resonance measurements at room temperature to characterize the spin properties of V$ _\text{B}^{-} $ defects, showing zero-filed splitting of $ \sim $ 3.47 GHz. We compare the photoluminescence intensity and spin properties of V$ _\text{B}^{-} $ defects generated by different implantation parameters, such as fluence, energy and ion species. With proper parameters, we can create V$ _\text{B}^{-} $ defects successfully with high probability. Our results provide a simple and practicable method to create spin defects in hBN, which is of great significance for integrated hBN-based devices.

quant-ph