SearcharxivSearch

arXiv subjects

Y. Mikami

Publications and source records attributed to Y. Mikami.

14 recordsLinked to original sources

Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter

A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.

physics.ins-det

Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

physics.ins-det

Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.

physics.ins-det

Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter

We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.

physics.ins-det

Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques

The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.

physics.ins-det

Electromagnetic response of a highly granular hadronic calorimeter

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.

physics.ins-det

Design and performance of a CMOS study sensor for a binary readout electromagnetic calorimeter

We present a study of a CMOS test sensor which has been designed, fabricated and characterised to investigate the parameters required for a binary readout electromagnetic calorimeter. The sensors were fabricated with several enhancements in addition to standard CMOS processing. Detailed simulations and experimental results of the performance of the sensor are presented. The sensor and pixels are shown to behave in accordance with expectations and the processing enhancements are found to be essential to achieve the performance required.

physics.ins-det

Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype

A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.

physics.ins-det

Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype

An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.

physics.ins-det

A digital ECAL based on MAPS

Progress is reported on the development and testing of Monolithic Active Pixel Sensors (MAPS) for a Si-W ECAL for the ILC. Using laser and source setups, a first version of the sensor has been characterised through measurements of the absolute gain calibration, noise and pedestal. The pixel-to-pixel gain spread is 10%. Charge diffusion has been measured and found to be compatible with simulation results. The charge collected by a single pixel varies from 50% to 20% depending on where it is generated. After adding detector effects to the Geant4 simulation of an ILC-like ECAL, using the measured parameters, the energy resolution is found to be 35% higher than the ideal resolution, but is still lower than the resolution obtained for an equivalent analogue ECAL.

physics.ins-det

Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.

physics.ins-det

Monolithic Active Pixel Sensors (MAPS) in a quadruple well technology for nearly 100% fill factor and full CMOS pixels

In this paper we present a novel, quadruple well process developed in a modern 0.18mu CMOS technology called INMAPS. On top of the standard process, we have added a deep P implant that can be used to form a deep P-well and provide screening of N-wells from the P-doped epitaxial layer. This prevents the collection of radiation-induced charge by unrelated N-wells, typically ones where PMOS transistors are integrated. The design of a sensor specifically tailored to a particle physics experiment is presented, where each 50mu pixel has over 150 PMOS and NMOS transistors. The sensor has been fabricated in the INMAPS process and first experimental evidence of the effectiveness of this process on charge collection is presented, showing a significant improvement in efficiency.

physics.ins-det

A MAPS-based Digital Electromagnetic Calorimeter for the ILC

A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical sensor is done using a detailed three-dimensional charge spread algorithm. Physics studies of the sensor are done including a digitisation algorithm taking into account the charge sharing, charge collection efficiency, noise, and dead areas. The influence of the charge sharing effect is found to be important and hence needs to be measured precisely.

physics.ins-det

Measurements of the $D_{sJ}$ resonance properties

We report measurements of the properties of the $D_{sJ}^+(2317)$ and $D_{sJ}^+(2457)$ resonances produced in continuum $e^+ e^-$ annihilation near $\sqrt{s}=10.6 \mathrm{GeV}$. The analysis is based on an $86.9 \mathrm{fb^{-1}}$ data sample collected %at and 60 MeV below the $Υ(4S)$ resonance with with the Belle detector at KEKB. We determine the masses to be $M(D_{sJ}^+(2317)) = 2317.2 \pm 0.5(\mathrm{stat}) \pm 0.9(\mathrm{syst}) \mathrm{MeV}/c^2$ and $M(D_{sJ}^+(2457))=2456.5 \pm 1.3(\mathrm{stat}) \pm 1.3(\mathrm{syst}) \mathrm{MeV}/c^2$. We observe the radiative decay mode $D_{sJ}^+(2457) \to D_s^+ γ$ and the dipion decay mode $D_{sJ}^+(2457) \to D_s^+ π^+ π^-$, and determine their branching fractions. No corresponding decays are observed for the $D_{sJ}(2317)$ state. These results are consistent with the spin-parity assignments of $0^+$ for the $D_{sJ}(2317)$ and $1^+$ for the $D_{sJ}(2457)$.

hep-ex