SearcharxivSearch

arXiv subjects

Y. Odani

Publications and source records attributed to Y. Odani.

3 recordsLinked to original sources

A new search for the $K_{L} \to π^0 ν\overlineν$ and $K_{L} \to π^{0} X^{0}$ decays

We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L} \to π^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an invisible particle with a mass of 135 MeV/$c^{2}$.

hep-ex

Long-lived neutral-kaon flux measurement for the KOTO experiment

The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.

physics.ins-det

Photon-Veto Counters at the Outer Edge of the Endcap Calorimeter for the KOTO Experiment

The Outer-Edge Veto (OEV) counter subsystem for extra-photon detection from the backgrounds for the? $K^0_L\rightarrowπ^0ν\barν$ decay is located at the outer edge of the endcap CsI calorimeter of the KOTO experiment at J-PARC. The subsystem is composed of 44 counters with different cross-sectional shapes. All counters are made of lead and scintillator plates and read out through wavelength-shifting fibers. In this paper, we discuss the design and performances of the OEV counters under heavy load ($\sim8$ tons/m$^2$) in vacuum. For 1-MeV energy deposit, the average light yield and time resolution are 20.9 photo-electrons and 1.5 ns, respectively. Although no pronounced peak by minimum-ionizing particles is observed in the energy distributions, an energy calibration method with cosmic rays works well in monitoring the gain stability with an accuracy of a few percent.

physics.ins-det