SearcharxivSearch

arXiv subjects

Y. Uesugi

Publications and source records attributed to Y. Uesugi.

5 recordsLinked to original sources

Study of Position Sensitive Silicon Detector (PSD) for SiW-ECAL at ILC

We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position resolution of the electromagnetic calorimeter (ECAL) of the ILD detector will be improved by introducing PSDs to detection layers. We have been developing the PSDs for several years. In the previous production we found that the charge separation is not optimally done due to the readout impedance. To solve the issue, we produced new PSDs with higher surface resistance with an additional resistive layer on the surface. We also implemented several techniques to decrease position distortion and increase signal-to-noise ratio which are essential for the optimal position resolution. The measurements on the prototype sensors are ongoing, including radiation source measurement and laser measurement using an ASIC for silicon pad detectors.

physics.ins-det

Quark charge identification for $e^{+}e^{-}$ to $q\bar{q}$ study

The process $e^{+}e^{-} \to q\bar{q}$ plays an important role in electroweak precision measurements. We are studying this process with ILD full simulation. The key for the reconstruction of the quark pair final states is quark charge identification (ID). We report the progress of charge ID study in detail. In particular, we investigate the performance of the charge ID for each decay mode of the heavy hadrons to know the possibilities of improvements of the charge ID.

physics.ins-det

Development of optical resonant cavities for laser-Compton scattering

We have been developing optical resonant cavities for laser-Compton scattering experiment at the Accelerator Test Facility in KEK. The main subject of the R&D is to increase laser pulse energy by coherently accumulating the pulses in an optical resonant cavity. We report previous results, current status and future prospects, including a new idea of an optical resonant cavity.

physics.acc-ph

Feedback-free optical cavity with self-resonating mechanism

We demonstrated the operation of a high finesse optical cavity without utilizing an active feedback system to stabilize the resonance. The effective finesse, which is a finesse including the overall system performance, of the cavity was measured to be $394,000 \pm 10,000$, and the laser power stored in the cavity was $2.52 \pm 0.13$ kW, which is approximately 187,000 times greater than the incident power to the cavity. The stored power was stabilized with a fluctuation of $1.7 \%$, and we confirmed continuous cavity operation for more than two hours. This result has the potential to trigger an innovative evolution for applications that use optical resonant cavities such as compact photon sources with laser-Compton scattering or cavity enhanced absorption spectroscopy.

physics.optics

Development of an intense positron source using a crystal--amorphous hybrid target for linear colliders

In a conventional positron source driven by a few GeV electron beam, a high amount of heat is loaded into a positron converter target to generate intense positrons required by linear colliders, and which would eventually damage the converter target. A hybrid target, composed of a single crystal target as a radiator of intense gamma--rays, and an amorphous converter target placed downstream of the crystal, was proposed as a scheme which could overcome the problem.This paper describes the development of an intense positron source with the hybrid target. A series of experiments on positron generation with the hybrid target has been carried out with a 8--GeV electron beam at the KEKB linac. We observed that positron yield from the hybrid target increased when the incident electron beam was aligned to the crystal axis and exceeded the one from the conventional target with the converter target of the same thickness, when its thickness is less than about 2 radiation length. The measurements in the temperature rise of the amorphous converter target was successfully carried out by use of thermocouples. These results lead to establishment to the evaluation of the hybrid target as an intense positron source.

physics.acc-ph