SearcharxivSearch

arXiv subjects

Y. W. Liu

Publications and source records attributed to Y. W. Liu.

3 recordsLinked to original sources

Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

physics.ins-det

Parametric Auto-Excitation of Magnetic Droplet Soliton Perimeter Modes

Recent experiments performed in current-driven nano-contacts with strong perpendicular anisotropy have shown that spin-transfer torque can drive self-localized spin waves [1, 2] that above a certain threshold intensity can condense into a highly nonlinear magnetodynamic and nano-sized state known as a magnetic droplet soliton [3]. Here we demonstrate analytically, numerically, and experimentally that at sufficiently large driving currents, and for a spin polarization that is tilted away from the film normal, the circular droplet soliton can become unstable to periodic excitations of its perimeter. We furthermore show that these perimeter excitation modes (PEMs) are parametrically excited when the fundamental droplet soliton precession frequency is close to twice the frequency of one or more of the PEMs. As a consequence, for increasing applied fields, progressively higher PEMs can be excited. Quantitative agreement with experiment confirms this picture.

cond-mat.mes-hall

Measurement of the 1s-2s energy interval in muonium

The 1s-2s interval has been measured in the muonium ({$μ^+e^-$}) atom by Doppler-free two-photon laser spectroscopy. The frequency separation of the states was determined to be 2 455 528 941.0(9.8) MHz in good agreement with quantum electrodynamics. The muon-electron mass ratio can be extracted and is found to be 206.768 38(17). The result may be interpreted as measurement of the muon-electron charge ratio as $-1- 1.1(2.1)\cdot 10^{-9}$.

hep-ex