Searcharxiv⌕ Search

arXiv subjects

Y. Zhou

Publications and source records attributed to Y. Zhou.

At least 37 records · Page 2Linked to original sources

Judicious Partitions in Edge-Weighted Graphs with Bounded Maximum Weighted Degree

In this paper, we investigate bounds for the following judicious $k$-partitioning problem: Given an edge-weighted graph $G$, find a $k$-partition $(V_1,V_2,\dots ,V_k)$ of $V(G)$ such that the total weight of edges in the heaviest induced subgraph, $\max_{i=1}^k w(G[V_i])$, is minimized. In our bounds, we also take into account the weight $w(V_1,V_2,\dots,V_k)$ of the cut induced by the partition (i.e., the total weight of edges with endpoints in different parts) and show the existence of a partition satisfying tight bounds for both quantities simultaneously. We establish such tight bounds for the case $k=2$ and, to the best of our knowledge, present the first (even for unweighted graphs) completely tight bound for $k=3$. We also show that, in general, these results cannot be extended to $k \geq 4$ without introducing an additional lower-order term, and we propose a corresponding conjecture. Moreover, we prove that there always exists a $k$-partition satisfying $\max \left\{ w(G[V_i]) : i \in [k] \right\} \leq \frac{w(G)}{k^2} + \frac{k - 1}{2k^2} Δ_w(G),$ where $Δ_w(G)$ denotes the maximum weighted degree of $G$. This bound is tight for every integer $k\geq 2$.

math.CO↗

Possible quantum spin liquid state of CeTa$_7$O$_{19}$

CeTa$_7$O$_{19}$ is a recently found two-dimensional triangular lattice antiferromagnet without showing magnetic order. We grew high-quality CeTa$_7$O$_{19}$ single crystals and studied the low-temperature magnetic susceptibility, specific heat and thermal conductivity. The dc magnetic susceptibility and magnetization reveal its nature of effective spin-1/2, easy axis anisotropy, and antiferromagnetic spin coupling. The ultralow-temperature ac susceptibility and specific heat data indicate the absence of any phase transition down to 20 mK. The ultralow-temperature thermal conductivity ($κ$) at zero magnetic field exhibits a non-zero residual term $κ_0/T =$ 0.0056 W/K$^2$m. Although the magnetic field dependence of $κ$ is rather weak, the 14 T thermal conductivity shows an essential zero residual term. All these results point to a possible ground state of quantum spin liquid.

cond-mat.str-el↗

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det↗

Ionization potential of radium monofluoride

The ionization potential (IP) of radium monofluoride (RaF) was measured to be 4.969(2)[10] eV, revealing a relativistic enhancement in the series of alkaline earth monofluorides. The results are in agreement with a relativistic coupled-cluster prediction of 4.969[7] eV, incorporating up to quantum electrodynamics corrections. Using the same computational methodology, an improved calculation for the dissociation energy ($D_{0}$) of 5.54[5] eV is presented. This confirms that radium monofluoride joins the small group of diatomic molecules for which $D_{0}>\mathrm{IP}$, paving the way for precision control and interrogation of its Rydberg states.

physics.atom-ph↗

The solar beryllium abundance revisited with 3D non-LTE models

The present-day abundance of beryllium in the solar atmosphere provides clues about mixing mechanisms within stellar interiors. However, abundance determinations based on the Be II 313.107 nm line are prone to systematic errors due to imperfect model spectra. These errors arise from missing continuous opacity in the UV, a significant unidentified blend at 313.102 nm, departures from local thermodynamic equilibrium (LTE), and microturbulence and macroturbulence fudge parameters associated with one-dimensional (1D) hydrostatic model atmospheres. Although these factors have been discussed in the literature, no study has yet accounted for all of them simultaneously. To address this, we present 3D non-LTE calculations for neutral and ionised beryllium in the Sun. We used these models to derive the present-day solar beryllium abundance, calibrating the missing opacity on high resolution solar irradiance data and the unidentified blend on the centre-to-limb variation. We find a surface abundance of 1.21 $\pm$ 0.05 dex, which is significantly lower than the value of 1.38 dex that has been commonly adopted since 2004. Taking the initial abundance via CI chondrites, our result implies that beryllium has been depleted from the surface by an extra 0.11 $\pm$ 0.06 dex, or 22 $\pm$ 11%, on top of any effects of atomic diffusion. This is in tension with standard solar models, which predict negligible depletion, as well as with contemporary solar models that have extra mixing calibrated on the abundances of helium and lithium, which predict excessive depletion. These discrepancies highlight the need for further improvements to the physics in solar and stellar models.

astro-ph.SR↗

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det↗

A high rate and high timing photoelectric detector prototype with RPC structure

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the single photoelectron performance of different mixed gases was tested with an ultraviolet laser. The detector uses a low resistivity ($\sim1.4\cdot 10^{10} Ω\cdot cm$) float glass so that its rate capability is significantly higher than that of ordinary float glass($10^{12}\sim10^{14} Ω\cdot cm$), the laser test results show that in MRPC gas($R134a/iC_{4}H_{10}/SF_{6}(85/10/5)$), the single photoelectron time resolution is best to reach 20.3 ps at a gas gain of $7\cdot 10^{6}$. Increasing the proportion of $iC_{4}H_{10}$ can effectively reduce the probability of photon feedback, without changing the time resolution and maximum gain. In addition to being applied to high-precision time measurement scenarios (eg:T0, TOF), the detector can also quantitatively test the single photoelectron performance of different gases and will be used to find eco-friendly MRPC gases.

physics.ins-det↗

Monitoring TES Loop Gain in Frequency Multiplexed Readout

We present a method for precise monitoring of the loop gain of transition edge sensors (TES) under electrothermal feedback. The measurement is implemented on the ICE DfMux electronics and operates simultaneously with Digital Active Nulling (DAN). It uses one additional bias sinusoid per TES and does not require any additional readout channels. The loop gain monitor is being implemented on the Simons Array and is an integral part of the baseline calibration strategy for the upcoming LiteBIRD satellite.

astro-ph.IM↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det↗

LiteBIRD Science Goals and Forecasts: Primordial Magnetic Fields

We present detailed forecasts for the constraints on primordial magnetic fields (PMFs) that will be obtained with the LiteBIRD satellite. The constraints are driven by the effects of PMFs on the CMB anisotropies: the gravitational effects of magnetically-induced perturbations; the effects on the thermal and ionization history of the Universe; the Faraday rotation imprint on the CMB polarization; and the non-Gaussianities induced in polarization anisotropies. LiteBIRD represents a sensitive probe for PMFs and by exploiting all the physical effects, it will be able to improve the current limit coming from Planck. In particular, thanks to its accurate $B$-mode polarization measurement, LiteBIRD will improve the constraints on infrared configurations for the gravitational effect, giving $B_{\rm 1\,Mpc}^{n_{\rm B} =-2.9} < 0.8$ nG at 95% C.L., potentially opening the possibility to detect nanogauss fields with high significance. We also observe a significant improvement in the limits when marginalized over the spectral index, $B_{1\,{\rm Mpc}}^{\rm marg}< 2.2$ nG at 95% C.L. From the thermal history effect, which relies mainly on $E$-mode polarization data, we obtain a significant improvement for all PMF configurations, with the marginalized case, $\sqrt{\langle B^2\rangle}^{\rm marg}<0.50$ nG at 95% C.L. Faraday rotation constraints will take advantage of the wide frequency coverage of LiteBIRD and the high sensitivity in $B$ modes, improving the limits by orders of magnitude with respect to current results, $B_{1\,{\rm Mpc}}^{n_{\rm B} =-2.9} < 3.2$ nG at 95% C.L. Finally, non-Gaussianities of the $B$-mode polarization can probe PMFs at the level of 1 nG, again significantly improving the current bounds from Planck. Altogether our forecasts represent a broad collection of complementary probes, providing conservative limits on PMF characteristics that will be achieved with LiteBIRD.

astro-ph.CO↗

Long time regularity of the $p$-Gauss curvature flow with flat side

In this paper, we prove the long time regularity of the interface in the $p$-Gauss curvature flow with flat side in all dimensions for $p>\frac1n$. Here the interface is the boundary of the flat part in the flow. In dimension $2$, this problem was solved in \cite{DL2004} for $p=1$ and in \cite{KimLeeRhee2013} for $p\in(1/2,1)$. We utilize the duality method to transform the Gauss curvature flow to a singular parabolic Monge-Ampère equation, and prove the regularity of the interface by studying the asymptotic cone of the parabolic Monge-Ampère equation in the polar coordinates.

math.AP↗

Regularity of the free boundary for a semilinear vector-valued minimization problem

In this paper, we consider the following semilinear vector-valued minimization problem $$\min\left\{\int_{D}({|\nabla\mathbf{u}|}^2 + F(|\mathbf{u}|))dx: \ \ \mathbf{u}\in W^{1,2}(D; \mathbb{R}^m) \ \text{and} \ \mathbf{u}=\mathbf{g}\ \text{on} \ \partial D\right\},$$ where $\mathbf{u}: D\to \mathbb{R}^m$ ($ m\geq 1$) is a vector-valued function, $D\subset \mathbb{R}^n$ ($n\geq 2$) is a bounded Lipschitz domain, $\mathbf{g}\in W^{1,2}(D; \mathbb{R}^m)$ is a given vector-valued function and $F:[0, \infty)\rightarrow \mathbb{R}$ is a given function. This minimization problem corresponds to the following semilinear elliptic system \begin{equation*} Δ\mathbf{u}=\frac{1}{2}F'(|\mathbf{u}|)\cdot\frac{\mathbf{u}}{|\mathbf{u}|}χ_{\{|\mathbf{u}|>0\}}, \end{equation*} where $χ_A$ denotes the characteristic function of the set A. The linear case that $F'\equiv 2$ was studied in the previous elegant work by Andersson, Shahgholian, Uraltseva and Weiss [Adv. Math 280, 2015], in which an epiperimetric inequality played a crucial role to indicate an energy decay estimate and the uniqueness of blow-up limit. However, this epiperimetric inequality cannot be directly applied to our case due to the more general non-degenerate and non-homogeneous term $F$ which leads to Weiss' boundary adjusted energy does not have scaling properties. Motivated by the linear case, when $F$ satisfies some assumptions, we establish successfully a new epiperimetric inequality, it can deal with term which is not scaling invariant in Weiss' boundary adjusted energy. As an application of this new epiperimetric inequality, we conclude that the free boundary $D\cap \partial\{|\mathbf{u}|>0\}$ is a locally $C^{1,β}$ surface near the regular points for some $β\in (0,1)$.

math.AP↗

Characterisation of resistive MPGDs with 2D readout

Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.

physics.ins-det↗

Gas selection for Xe-based LCP-GEM detectors onboard the CubeSat X-ray observatory NinjaSat

We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas mixture at a pressure of 1.2 atm that is sensitive to high-energy X-rays. In addition, an effective gain of over 300 is required for a single GEM so that the 2 keV X-ray signal can be sufficiently larger than the electrical noise. At first, we measured the effective gains of GEM in nine Xe-based gas mixtures (combinations of Xe, Ar, CO2, CH4, and dimethyl ether; DME) at 1.0 atm. The highest gains were obtained with Xe/Ar/DME mixtures, while relatively lower gains were obtained with Xe/Ar/CO2, Xe/Ar/CH4, and Xe+quencher mixtures. Based on these results, we selected the Xe/Ar/DME (75%/24%/1%) mixture at 1.2 atm as the sealed gas for GMC. Then we investigated the dependence of an effective gain on the electric fields in the drift and induction gaps ranging from 100-650 V cm$^{-1}$ and 500-5000 V cm$^{-1}$, respectively, in the selected gas mixture. The effective gain weakly depended on the drift field while it was almost linearly proportional to the induction field: 2.4 times higher at 5000 V cm$^{-1}$ than at 1000 V cm$^{-1}$. With the optimal induction and drift fields, the flight model GMC achieves an effective gain of 460 with an applied GEM voltage of 590 V.

astro-ph.IM↗

Interpreting Training Aspects of Deep-Learned Error-Correcting Codes

As new deep-learned error-correcting codes continue to be introduced, it is important to develop tools to interpret the designed codes and understand the training process. Prior work focusing on the deep-learned TurboAE has both interpreted the learned encoders post-hoc by mapping these onto nearby ``interpretable'' encoders, and experimentally evaluated the performance of these interpretable encoders with various decoders. Here we look at developing tools for interpreting the training process for deep-learned error-correcting codes, focusing on: 1) using the Goldreich-Levin algorithm to quickly interpret the learned encoder; 2) using Fourier coefficients as a tool for understanding the training dynamics and the loss landscape; 3) reformulating the training loss, the binary cross entropy, by relating it to encoder and decoder parameters, and the bit error rate (BER); 4) using these insights to formulate and study a new training procedure. All tools are demonstrated on TurboAE, but are applicable to other deep-learned forward error correcting codes (without feedback).

cs.IT↗

Cosmoglobe DR1 results. II. Constraints on isotropic cosmic birefringence from reprocessed WMAP and Planck LFI data

Cosmic birefringence is a parity-violating effect that might have rotated the plane of linearly polarized light of the cosmic microwave background (CMB) by an angle $β$ since its emission. This has recently been measured to be non-zero at a statistical significance of $3.6σ$ in the official Planck PR4 and 9-year WMAP data. In this work, we constrain $β$ using the reprocessed BeyondPlanck LFI and Cosmoglobe DR1 WMAP polarization maps. These novel maps have both lower systematic residuals and a more complete error description than the corresponding official products. Foreground $EB$ correlations could bias measurements of $β$, and while thermal dust $EB$ emission has been argued to be statistically non-zero, no evidence for synchrotron $EB$ power has been reported. Unlike the dust-dominated Planck HFI maps, the majority of the LFI and WMAP polarization maps are instead dominated by synchrotron emission. Simultaneously constraining $β$ and the polarization miscalibration angle, $α$, of each channel, we find a best-fit value of $β=0.35^{\circ}\pm0.70^{\circ}$ with LFI and WMAP data only. When including the Planck HFI PR4 maps, but fitting $β$ separately for dust-dominated, $β_{>70\,\mathrm{GHz}}$, and synchrotron-dominated channels, $β_{\leq 70\,\mathrm{GHz}}$, we find $β_{\leq 70\,\mathrm{GHz}}=0.53^{\circ}\pm0.28^\circ$. This differs from zero with a statistical significance of $1.9σ$, and the main contribution to this value comes from the LFI 70 GHz channel. While the statistical significances of these results are low on their own, the measurement derived from the LFI and WMAP synchrotron-dominated maps agrees with the previously reported HFI-dominated constraints, despite the very different astrophysical and instrumental systematics involved in all these experiments.

astro-ph.CO↗