SearcharxivSearch

arXiv subjects

Ya-Qing Liu

Publications and source records attributed to Ya-Qing Liu.

13 recordsLinked to original sources

GECAM discovery of a peculiar magnetar X-ray burst (MXB 221120) from SGR J1935+2154 associated with a fast radio burst

Fast radio bursts (FRBs) are enigmatic cosmic transients of millisecond duration observed in the radio band. The identification of FRB-associated magnetar X-ray bursts (MXBs) from galactic magnetar SGR J1935+2154 suggests that at least a fraction of FRBs can be produced from magnetar activity. However, the sample size of FRB-associated MXBs is still very small. Here we report a bright and peculiar FRB-associated MXB from SGR J1935+2154 detected by GECAM on November 20, 2022, dubbed MXB 221120. We find that both temporal and spectral properties of MXB 221120 exhibit distinctive features. Its light curve could be generally described by a single FRED function with superposition of several narrow pulses. Interestingly, we identify a possible QPO feature with center frequency of ~18 Hz in this MXB. The time-integrated spectrum is best fitted by a blackbody model with temperature (kT ) of 18.6 keV, rendering it the first thermal spectrum FRB-associated MXB from SGR J1935+2154. Compared to other MXBs with single emission episode, MXB 221120 has longer duration and higher blackbody temperature, making it an outlier in the burst sample. These results indicate that MXB 221120 may be produced by a special mechanism with extreme physical conditions.

astro-ph.HE

Comprehensive Measurement of Spectral Evolution in a GRB Flare: High Time-Resolution Insights into the "Double-Tracking" Phenomenon

The spectral evolution characteristics of the prompt emission in gamma-ray bursts (GRBs) have been extensively studied, but detailed investigations of spectral evolution in a GRB flare remain lacking. In this work, we present the first analysis of spectral parameter evolution in a GRB flare through high time-resolved spectral fitting of the Brightest Flare in GRB 221009A. We find that the $\alpha$-Flux, $E_p$-Flux, and $E_p$-$\alpha$ relationships during both the overall phase and the rise phase of flare can be well described by simple power-law model, showing positive correlations. Therefore, we conclude that Brightest Flare exhibits "Double-tracking" behavior. Since values of $\alpha$ do not exceed the synchrotron "death line" (-2/3), we explain this phenomenon using a magnetic dissipation synchrotron radiation model. In the decay phase of flare, the $E_p$-Flux and $E_p$-$\alpha$ correlations become notably flatter, with their power-law indices decreasing significantly compared to those in the rise phase. This may be due to the fact that the next flare begins to erupt before the Brightest Flare has completely ended, resulting in the combined effects of both two flares. Our study of spectral parameter relations of the Brightest Flare provides new insights into the radiation mechanisms of both GRB prompt emission and flares.

astro-ph.HE

GECAM discovery of the second FRB-associated Magnetar X-ray Burst from SGR J1935+2154

Fast radio burst (FRB) is mysterious phenomenon with millisecond-duration radio pulses observed mostly from cosmological distance. The association between FRB 200428 and a magnetar X-ray burst (MXB) from SGR J1935+2154 has significantly advanced the understanding of FRB and magnetar bursts. However, it is uncertain whether this association between MXB and FRB (i.e. MXB/FRB 200428) is genuine or just coincidental only based on this single event. Here we report the discovery of a bright ($\rm\sim7.6\times10^{-7}\,erg \cdot cm^{-2}$ in 1-250 keV) magnetar X-ray burst detected by GECAM on October 14th, 2022 (dubbed as MXB 221014) from SGR J1935+2154, which is associated with a FRB detected by CHIME and GBT. We conducted a detailed temporal and spectral analysis of MXB 221014 with GECAM data and find that it is a bright and typical ($T_{90}\sim$250 ms) X-ray burst from this magnetar. Interestingly, we find two narrow X-ray pulses in the MXB, one of which temporally aligns with the main pulse of the FRB 221014 $\sim5.70$ ms latter than the peak time of FRB 221014), resembling the feature found in MXB/FRB 200428. Furthermore, we did comprehensive comparison between MXB/FRB 221014 and MXB/FRB 200428, and find that while the two events share several common features, they also exhibit distinct differences, highlighting the variety of the MXB-FRB association morphology. This finding not only confirms the association between MXB and FRB but also provides new insights into the mechanism of and the relationship between FRB and MXB.

astro-ph.HE

Systematic Study of the Simultaneous Events Detected by GECAM

GECAM is a constellation of all-sky monitors in hard X-ray and gamma-ray band primarily aimed at high energy transients such as gamma-ray bursts, soft gamma-ray repeaters, solar flares and terrestrial gamma-ray flashes. As GECAM has the highest temporal resolution (0.1~$μ$s) among instruments of its kind, it can identify the so-called simultaneous events (STE) that deposit signals in multiple detectors nearly at the same time (with a 0.3~$μ$s window). However, the properties and origin of STE have not yet been explored. In this work, we implemented, for the first time, a comprehensive analysis of the STE detected by GECAM, including their morphology, energy deposition, and the dependence on the geomagnetic coordinates. We find that these STE probably result from direct interactions between high-energy charged cosmic rays and satellite. These results demonstrate that GECAM can detect, identify, and characterize high-energy cosmic rays, making it a Micro Cosmic-Ray Observatory (MICRO) in low Earth orbit.

astro-ph.HE

Brightest GRB flare observed in GRB 221009A: bridge the last gap between flare and prompt emission in GRB

Flares are usually observed during the afterglow phase of Gamma-Ray Bursts (GRBs) in soft X-ray, optical and radio bands, but rarely in gamma-ray band. Despite the extraordinary brightness, GECAM-C has accurately measured both the bright prompt emission and flare emission of GRB 221009A without instrumental effects, offering a good opportunity to study the relation between them. In this work, we present a comprehensive analysis of flare emission of GRB 221009A, which is composed of a series of flares. Among them, we identify an exceptionally bright flare with a record-breaking isotropic energy $E_{\rm iso} = 1.82 \times 10^{53}$ erg of GRB flares. It exhibits the highest peak energy ever detected in GRB flares, $E_{\rm peak} \sim 300$ keV, making it a genuine gamma-ray flare. It also shows rapid rise and decay timescales, significantly shorter than those of typical X-ray flares observed in soft X-ray or optical band, but comparable to those observed in prompt emissions. Despite these exceptional properties, the flare shares several common properties with typical GRB flares. We note that this is the first observation of a GRB flare in the keV-MeV band with sufficiently high temporal resolution and high statistics, which bridges the last gap between prompt emission and flare.

astro-ph.HE

Performance of the Gamma-ray Transient Monitor at the IHEP Electron-Beam Facility

Gamma-Ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite, with the scientific objective of detecting gamma-ray bursts in the energy range of 20 keV to 1 MeV. GTM is equipped with five Gamma-Ray Transient Probes (GTPs), utilizing NaI(Tl) scintillators coupled with silicon photomultiplier (SiPM) arrays for signal readout. To test the performance of the GTP in detecting electrons, we used the IHEP Electron-Beam Facility (a continuous-energy-tunable, low-current, quasi-single-electron accelerator) for ground-based electron tests of the GTP. This paper provides a detailed description of the operating principles of the electron accelerator and presents the process and results of the GTP electron-beam tests. The test results show that the GTP has a dead time of less than 4 $\mu$s for normal signals and approximately 70 $\mu$s for overflow signals, consistent with the design specifications. The time-recording capability of the GTP was tested and found to be normal, with accurate recording of overflow events. The GTP's response to electrons in the 0.4-1.4 MeV range is also normal. Additionally, we used Geant4 to simulate the GTP's energy response and performed a comparative analysis of the simulation and experimental results. The performance tests and ground-based electron calibration validated the design of the GTP and enhanced the GTP's mass model, laying the foundation for payload development, in-orbit observation strategies, and scientific data analysis.

astro-ph.IM

The Energy Response of LaBr3(Ce), LaBr3(Ce,Sr) and NaI(Tl) Crystals for GECAM

The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons, radioactive sources, and mono-energetic X-rays. The non-linearity test results for Compton electrons and X-rays displayed substantial differences, with all three crystals showing higher non-linearity for X-rays and gamma-rays than for Compton electrons. Despite LaBr3(Ce) and LaBr3(Ce,Sr) crystals having higher absolute light yields, they exhibited a noticeable non-linear decrease in light yield, especially at energies below 400 keV. The NaI(Tl) crystal demonstrated excess light output in the 6~200 keV range, reaching a maximum excess of 9.2% at 30 keV in X-ray testing and up to 15.5% at 14 keV during Compton electron testing, indicating a significant advantage in the detection of low-energy gamma rays. Furthermore, this paper explores the underlying causes of the observed non-linearity in these crystals. This study not only elucidates the detector responses of GECAM, but also marks the inaugural comprehensive investigation into the non-linearity of domestically produced lanthanum bromide and sodium iodide crystals.

physics.ins-det

Calibration of the Timing Performance of GECAM-C

As a new member of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) after GECAM-A and GECAM-B, GECAM-C (originally called HEBS), which was launched on board the SATech-01 satellite on July 27, 2022, aims to monitor and localize X-ray and gamma-ray transients from $\sim$ 6 keV to 6 MeV. GECAM-C utilizes a similar design to GECAM but operates in a more complex orbital environment. In this work, we utilize the secondary particles simultaneously produced by the cosmic-ray events on orbit and recorded by multiple detectors, to calibrate the relative timing accuracy between all detectors of GECAM-C. We find the result is 0.1 $μ\rm s$, which is the highest time resolution among all GRB detectors ever flown and very helpful in timing analyses such as minimum variable timescale and spectral lags, as well as in time delay localization. Besides, we calibrate the absolute time accuracy using the one-year Crab pulsar data observed by GECAM-C and Fermi/GBM, as well as GECAM-C and GECAM-B. The results are $2.02\pm 2.26\ μ\rm s$ and $5.82\pm 3.59\ μ\rm s$, respectively. Finally, we investigate the spectral lag between the different energy bands of Crab pulsar observed by GECAM and GBM, which is $\sim -0.2\ {\rm μs\ keV^{-1}}$.

astro-ph.IM

Ground calibration of Gamma-Ray Detectors of GECAM-C

As a new member of GECAM mission, GECAM-C (also named High Energy Burst Searcher, HEBS) was launched onboard the SATech-01 satellite on July 27th, 2022, which is capable to monitor gamma-ray transients from $\sim$ 6 keV to 6 MeV. As the main detector, there are 12 gamma-ray detectors (GRDs) equipped for GECAM-C. In order to verify the GECAM-C GRD detector performance and to validate the Monte Carlo simulations of detector response, comprehensive on-ground calibration experiments have been performed using X-ray beam and radioactive sources, including Energy-Channel relation, energy resolution, detection efficiency, SiPM voltage-gain relation and the non-uniformity of positional response. In this paper, the detailed calibration campaigns and data analysis results for GECAM-C GRDs are presented, demonstrating the excellent performance of GECAM-C GRD detectors.

astro-ph.IM

Insight-HXMT and GECAM-C observations of the brightest-of-all-time GRB 221009A

GRB 221009A is the brightest gamma-ray burst ever detected since the discovery of this kind of energetic explosions. However, an accurate measurement of the prompt emission properties of this burst is very challenging due to its exceptional brightness. With joint observations of \textit{Insight}-HXMT and GECAM-C, we made an unprecedentedly accurate measurement of the emission during the first $\sim$1800 s of GRB 221009A, including its precursor, main emission (ME, which dominates the burst in flux), flaring emission and early afterglow, in the hard X-ray to soft gamma-ray band from $\sim$ 10 keV to $\sim$ 6 MeV. Based on the GECAM-C unsaturated data of the ME, we measure a record-breaking isotropic equivalent energy ($E_{\rm iso}$) of $\bf \sim 1.5 \times 10^{55}$ erg, which is about eight times the total rest-mass energy of the Sun. The early afterglow data require a significant jet break between 650 s and 1100 s, most likely at $\sim950$ s from the afterglow starting time $T_{AG}$, which corresponds to a jet opening angle of $\sim {0.7^\circ} \ (η_γn)^{1/8}$, where $n$ is the ambient medium density in units of $\rm cm^{-3}$ and $η_γ$ is the ratio between $γ$-ray energy and afterglow kinetic energy. The beaming-corrected total $γ$-ray energy $E_γ$ is $\sim 1.15 \times10^{51} \ (η_γn)^{1/4}$ erg, which is typical for long GRBs. These results suggest that this GRB may have a special central engine, which could launch and collimate a very narrowly beamed jet with an ordinary energy budget, leading to exceptionally luminous gamma-ray radiation per unit solid angle. Alternatively, more GRBs might have such a narrow and bright beam, which are missed by an unfavorable viewing angle or have been detected without distance measurement.

astro-ph.HE

Cross calibration of gamma-ray detectors (GRD) of GECAM-C

The gamma-ray detectors (GRDs) of GECAM-C onborad SATech-01 satellite is designed to monitor gamma-ray transients all over the sky from 6 keV to 6 MeV. The energy response matrix is the key to do spectral measurements of bursts, which is usually generated from GEANT4 simulation and partially verified by the ground calibration. In this work, energy response matrix of GECAM-C GRD is cross-calibrated with Fermi/GBM and Swift/BAT using a sample of Gamma-Ray Bursts (GRBs) and Soft Gamma-Ray Repeaters (SGRs). The calibration results show there is a good agreement between GECAM-C and other reasonably well calibrated instrument (i.e. Fermi/GBM and Swift/BAT). We also find that different GRD detectors of GECAM-C also show consistency with each other. All these results indicate that GECAM-C GRD can provide reliable spectral measurements.

astro-ph.IM

GECAM Localization of High Energy Transients and the Systematic Error

Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a pair of microsatellites (i.e. GECAM-A and GECAM-B) dedicated to monitoring gamma-ray transients including gravitational waves high-energy electromagnetic counterparts, Gamma-ray Bursts, Soft Gamma-ray Repeaters, Solar Flares and Terrestrial Gamma-ray Flashes. Since launch in December 2020, GECAM-B has detected hundreds of astronomical and terrestrial events. For these bursts, localization is the key for burst identification and classification as well as follow-up observations in multi-wavelength. Here, we propose a Bayesian localization method with Poisson data with Gaussian background profile likelihood to localize GECAM bursts based on the burst counts distribution in detectors with different orientations. We demonstrate that this method can work well for all kinds of bursts, especially for extremely short ones. In addition, we propose a new method to estimate the systematic error of localization based on a confidence level test, which can overcome some problems of the existing method in literature. We validate this method by Monte Carlo simulations, and then apply it to a burst sample with accurate location and find that the mean value of the systematic error of GECAM-B localization is $\sim 2.5^{\circ}$. By considering this systematic error, we can obtain a reliable localization probability map for GECAM bursts. Our methods can be applied to other gamma-ray monitors.

astro-ph.IM

The In-Flight Realtime Trigger and Localization Software of GECAM

Realtime trigger and localization of bursts are the key functions of GECAM, which is an all-sky gamma-ray monitor launched in Dec 10, 2020. We developed a multifunctional trigger and localization software operating on the CPU of the GECAM electronic box (EBOX). This onboard software has the following features: high trigger efficiency for real celestial bursts with a suppression of false triggers caused by charged particle bursts and background fluctuation, dedicated localization algorithm optimized for short and long bursts respetively, short time latency of the trigger information which is downlinked throught the BeiDou satellite navigation System (BDS). This paper presents the detailed design and deveopment of this trigger and localization software system of GECAM, including the main functions, general design, workflow and algorithms, as well as the verification and demonstration of this software, including the on-ground trigger tests with simulated gamma-ray bursts made by a dedicated X-ray tube and the in-flight performance to real gamma-ray bursts and magnetar bursts.

astro-ph.IM