Searcharxiv⌕ Search

arXiv subjects

Yakov I. Nesterets

Publications and source records attributed to Yakov I. Nesterets.

9 recordsLinked to original sources

Development and Validation of Patient-Specific Monte Carlo Dosimetry for Synchrotron Breast Phase-Contrast CT

This study develops and validates a patient-specific Monte Carlo (MC) dosimetry framework for propagation-based phase-contrast breast CT (BCT) at the Imaging and Medical Beamline (IMBL), ANSTO Australian Synchrotron, for accurate mean glandular dose (MGD) estimation. BCT provides 3D imaging without breast compression, improving comfort and visualization of internal structures for cancer detection. Propagation-based phase contrast improves soft-tissue contrast at equal or lower dose than conventional systems. Accurate dosimetry remains essential for safety and optimisation. Most MC-based MGD studies use non-patient-specific phantoms that ignore anatomical variability, while existing patient-specific methods lack a unified framework. Here, a voxel-based MC framework using EGSnrc was implemented to compute MGD in realistic anthropomorphic breast phantoms derived from synchrotron BCT images. IMBL beam characteristics were used as source inputs. Homogeneous phantoms were also generated to compute air Kerma to MGD conversion coefficients (DgN) for comparison with heterogeneous models. Simulations covered breast height, skin thickness, and photon energies (28 to 38 keV). Results show MGD depends strongly on anatomy and energy. Higher glandular density reduces MGD, while larger breast volume increases dose. A 2 mm increase in skin thickness reduces MGD by 10%. Differences between heterogeneous and homogeneous phantoms show variations in DgN, highlighting the need for anatomical realism. The framework provides a robust basis for patient-specific dosimetry in synchrotron phase-contrast BCT, enabling precise MGD estimation and supporting safe, optimised clinical imaging. This supports improved protocol design and contributes to standardised patient-specific dosimetry for clinical translation across varying breast anatomies and imaging conditions within synchrotron BCT applications.

physics.med-ph↗

High-energy X-ray phase-contrast CT of an adult human chest phantom

Propagation-based phase-contrast X-ray imaging is a promising technique for in~vivo medical imaging, offering lower radiation doses than traditional attenuation-based imaging. Previous studies have focused on X-ray energies below 50 keV for small-animal imaging and mammography. Here, we investigate the feasibility of high-energy propagation-based computed tomography for human adult-scale lung imaging at the Australian Synchrotron's Imaging and Medical Beamline. This facility is uniquely positioned for human lung imaging, offering a large field of view, high X-ray energies, and supporting clinical infrastructure. We imaged an anthropomorphic chest phantom (LungMan) between 50 keV and 80 keV across the range of possible sample-to-detector distances, with a photon-counting and an integrating detector. Strong phase-contrast fringes were observed with the photon-counting detector, even at high X-ray energies and a large pixel size relative to previous work, whereas the integrating detector with lower spatial resolution showed no clear phase effects. Measured X-ray phase-shifting properties of LungMan aligned well with reference soft tissue values, validating the phantom for phase-contrast studies. Imaging quality assessments suggest an optimal configuration at approximately 70 keV and the longest available propagation distance of 7.5 m, indicating potential benefit in positioning the patient in an upstream hutch. This study represents the first step towards clinical adult lung imaging at the Australian Synchrotron.

physics.med-ph↗

Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising

Breast cancer is the most frequently diagnosed human cancer in the United States at present. Early detection is crucial for its successful treatment. X-ray mammography and digital breast tomosynthesis are currently the main methods for breast cancer screening. However, both have known limitations in terms of their sensitivity and specificity to breast cancers, while also frequently causing patient discomfort due to the requirement for breast compression. Breast computed tomography is a promising alternative, however, to obtain high-quality images, the X-ray dose needs to be sufficiently high. As the breast is highly radiosensitive, dose reduction is particularly important. Phase-contrast computed tomography (PCT) has been shown to produce higher-quality images at lower doses and has no need for breast compression. It is demonstrated in the present study that, when imaging full fresh mastectomy samples with PCT, deep learning-based image denoising can further reduce the radiation dose by a factor of 16 or more, without any loss of image quality. The image quality has been assessed both in terms of objective metrics, such as spatial resolution and contrast-to-noise ratio, as well as in an observer study by experienced medical imaging specialists and radiologists. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialized synchrotron facilities.

physics.med-ph↗

Three-dimensional contrast transfer function in phase-contrast tomography

A new method is developed for three-dimensional (3D) reconstruction of multi-material objects using propagation-based X-ray phase-contrast tomography (PB-CT) with phase retrieval via the contrast transfer function (CTF) formalism. The approach differs from conventional PB-CT algorithms that apply phase retrieval on individual two-dimensional (2D) projections. Instead, this method involves performing phase retrieval to the CT-reconstructed volume in 3D. The CTF formalism is further extended to the cases of partially-coherent illumination and strongly absorbing samples. Simulated results demonstrate that the proposed post-reconstruction CTF method provides fast and stable phase retrieval, producing results equivalent to conventional pre-reconstruction 2D CTF phase retrieval. Moreover, it is shown that application can be highly localised to isolated objects of interest, without a significant loss of quality, thus leading to increased computational efficiency. Combined with the extended validity of the CTF to greater propagation distances, this method provides additional advantages over approaches based on the transport-of-intensity equation.

physics.med-ph↗

Noise-resolution uncertainty principle in classical and quantum systems

It is proved that the width of a function and the width of the distribution of its values cannot be made arbitrarily small simultaneously. In the case of ergodic stochastic processes, an ensuing uncertainty relationship is demonstrated for the product of correlation length and variance. A closely related uncertainty principle is also established for the average degree of fourth-order coherence and the spatial width of modes of bosonic quantum fields. However, it is shown that, in the case of stochastic and quantum observables, certain non-classical states with sub-Poissonian statistics, such as for example photon number squeezed states in quantum optics, can overcome the "classical" noise-resolution uncertainty limit. The described uncertainty relationship, which is fundamentally different from the Heisenberg and related uncertainty principles, can define an upper limit for the information capacity of communication and imaging systems. It is expected to be useful in a variety of problems in classical and quantum physics.

cond-mat.stat-mech↗

Fast three-dimensional phase retrieval in propagation-based x-ray tomography

The following paper describes a method for three-dimensional (3D) reconstruction of multi-material objects based on propagation-based X-ray phase-contrast tomography (PB-CT) with phase retrieval using the homogenous form of the Transport-of-Intensity equation (TIE-Hom). Unlike conventional PB-CT algorithms that perform phase retrieval of individual projections, the described post-reconstruction phase-retrieval method is applied in 3D to a localised region of the CT-reconstructed volume. We demonstrate via numerical simulations the accuracy and noise characteristics of the method under a variety of experimental conditions, comparing it to both conventional absorption tomography and two-dimensional (2D) TIE-Hom phase retrieval applied to projection images. The results indicate that the 3D post-reconstruction method generally achieves a modest improvement in noise suppression over existing PB-CT methods. It is also shown that potentially large computational gains over projection-based phase retrieval for multi-material samples are possible. In particular, constraining phase retrieval to a localised 3D region of interest reduces the overall computational cost and eliminates the need for multiple CT reconstructions and global 2D phase retrieval operations for each material within the sample.

physics.med-ph↗

On the van Cittert - Zernike theorem for intensity correlations and its applications

A reciprocal relationship between the autocovariance of the light intensity in the source plane and in the far-field detector plane is presented in a form analogous to the classical van Cittert - Zernike theorem, but involving intensity correlation functions. A "classical" version of the reciprocity relationship is considered first, based on the assumption of circular Gaussian statistics of the complex amplitudes in the source plane. The result is consistent with the theory of Hanbury Brown - Twiss interferometry, but it is shown to be also applicable to estimation of the source size or the spatial resolution of the detector from the noise power spectrum of flat-field images. An alternative version of the van Cittert - Zernike theorem for intensity correlations is then derived for a quantized electromagnetic beam in a coherent state, which leads to Poisson statistics for the intrinsic intensity of the beam.

physics.optics↗

On noise-resolution uncertainty in quantum field theory

An uncertainty inequality is presented that establishes a lower limit for the product of the variance of the time-averaged intensity of a mode of a quantized electromagnetic field and the degree of its spatial localization. The lower limit is determined by the vacuum fluctuations within the volume corresponding to the width of the mode. This result also leads to a generalized form of the Heisenberg uncertainty principle for boson fields in which the lower limit for the product of uncertainties in the spatial and momentum localization of a mode is equal to the product of Planck's constant and a dimensionless functional which reflects the joint signal-to-noise ratio of the position and momentum of vacuum fluctuations in the region of the phase space occupied by the mode. Experimental X-ray synchrotron measurements provide an initial verification of the proposed theory in the case of Poisson statistics.

quant-ph↗

Evaluation of Spatial Resolution and Noise Sensitivity of sLORETA Method for EEG Source Localization Using Low-Density Headsets

Electroencephalography (EEG) has enjoyed considerable attention over the past century and has been applied for diagnosis of epilepsy, stroke, traumatic brain injury and other disorders where 3D localization of electrical activity in the brain is potentially of great diagnostic value. In this study we evaluate the precision and accuracy of spatial localization of electrical activity in the brain delivered by a popular reconstruction technique sLORETA applied to EEG data collected by two commonly used low-density headsets with 14 and 19 measurement channels, respectively. Numerical experiments were performed for a realistic head model obtained by segmentation of MRI images. The EEG source localization study was conducted with a simulated single active dipole, as well as with two spatially separated simultaneously active dipoles, as a function of dipole positions across the neocortex, with several different noise levels in the EEG signals registered on the scalp. The results indicate that while the reconstruction accuracy and precision of the sLORETA method are consistently high in the case of a single active dipole, even with the low-resolution EEG configurations considered in the present study, successful localization is much more problematic in the case of two simultaneously active dipoles. The quantitative analysis of the width of the reconstructed distributions of the electrical activity allows us to specify the lower bound for the spatial resolution of the sLORETA-based 3D source localization in the considered cases.

physics.med-ph↗