SearcharxivSearch

arXiv subjects

Yameng Zhang

Publications and source records attributed to Yameng Zhang.

5 recordsLinked to original sources

Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning

Robotic ultrasound policies operating directly on B-mode images require extensive interaction data, whereas real-robot data collection is costly and safety-constrained. Simulation provides a scalable alternative, but zero-shot transfer depends not only on single-frame realism but also on whether simulated observations reproduce task-relevant feature changes induced by probe motion. We term this cross-domain consistency task-relevant feature-dynamics fidelity (TR-FDF). Under local regularity assumptions, our contraction analysis shows that greater sensitivity of TR-FDF mismatch to probe motion reduces the effective closed-loop contraction margin, whereas motion-independent errors primarily enlarge the residual error bound. Guided by this analysis, we develop a TR-FDF-oriented ultrasound simulator that combines a shared structural intermediate domain, trajectory-level fixed noise, and few-step conditional flow generation. In phantom experiments, a policy trained exclusively in simulation succeeded in 390 of 400 zero-shot deployments across four target planes. The simulator achieved an FID of 29.66 and generated observations at 67.1 Hz. Controlled interventions, ablations, and baseline comparisons showed that TR-FDF sensitivity complements single-frame realism in predicting zero-shot transfer performance.

cs.RO

Seeing Globally, Refining Locally: Global Visual Guidance and Local Ultrasound Cues for Robust Freehand 3-D Ultrasound Reconstruction

Freehand 3-D ultrasound (US) imaging has attracted increasing attention owing to its intuitive volumetric visualization, ease of use, and low cost. However, accurate 3-D reconstruction critically depends on stable probe pose estimation, yet existing trackerless methods remain susceptible to accumulated pose errors, particularly over long scanning trajectories. To address this limitation, we propose a global-to-local pose estimation framework that exploits external camera observations for globally stable localization and B-mode US images for anatomy-aware local refinement. Specifically, the framework comprises a dual-camera branch that performs contextual feature aggregation across camera views and temporal observations to estimate a globally consistent probe trajectory, and a B-mode branch that performs anatomical feature aggregation from sequential US images to capture tissue-dependent local motion cues. A cross-modal fusion module subsequently integrates the contextual camera features and anatomical US features to predict pose residuals and refine the camera-derived estimates in the transformation space. Furthermore, a multi-scale pose loss constrains relative motion over multiple temporal horizons to suppress accumulated drift during extended scans. The proposed framework is validated on phantom and in vivo datasets. On two in-house datasets (FUSION-J and FUSION-L) collected using different machines, the proposed US + Dual-Cam model reduces average trajectory drift to 1.67 mm and 1.29 mm, representing improvement of 16.50% and 27.12%, respectively, over a strong dual-camera baseline, while substantially outperforming US-only pose estimation (>13 mm drift). In in vivo forearm arteries reconstruction, it achieves Hausdorff distances of 1.58 mm, demonstrating the effectiveness of the proposed method on real clinical scenarios.

cs.CV

Freehand 3D Ultrasound Imaging: Sim-in-the-Loop Probe Pose Optimization via Visual Servoing

Freehand 3D ultrasound (US) imaging using conventional 2D probes offers flexibility and accessibility for diverse clinical applications but faces challenges in accurate probe pose estimation. Traditional methods depend on costly tracking systems, while neural network-based methods struggle with image noise and error accumulation, compromising reconstruction precision. We propose a cost-effective and versatile solution that leverages lightweight cameras and visual servoing in simulated environments for precise 3D US imaging. These cameras capture visual feedback from a textured planar workspace. To counter occlusions and lighting issues, we introduce an image restoration method that reconstructs occluded regions by matching surrounding texture patterns. For pose estimation, we develop a simulation-in-the-loop approach, which replicates the system setup in simulation and iteratively minimizes pose errors between simulated and real-world observations. A visual servoing controller refines the alignment of camera views, improving translational estimation by optimizing image alignment. Validations on a soft vascular phantom, a 3D-printed conical model, and a human arm demonstrate the robustness and accuracy of our approach, with Hausdorff distances to the reference reconstructions of 0.359 mm, 1.171 mm, and 0.858 mm, respectively. These results confirm the method's potential for reliable freehand 3D US reconstruction.

cs.RO

Semantic Scene Graph for Ultrasound Image Explanation and Scanning Guidance

Understanding medical ultrasound imaging remains a long-standing challenge due to significant visual variability caused by differences in imaging and acquisition parameters. Recent advancements in large language models (LLMs) have been used to automatically generate terminology-rich summaries orientated to clinicians with sufficient physiological knowledge. Nevertheless, the increasing demand for improved ultrasound interpretability and basic scanning guidance among non-expert users, e.g., in point-of-care settings, has not yet been explored. In this study, we first introduce the scene graph (SG) for ultrasound images to explain image content to ordinary and provide guidance for ultrasound scanning. The ultrasound SG is first computed using a transformer-based one-stage method, eliminating the need for explicit object detection. To generate a graspable image explanation for ordinary, the user query is then used to further refine the abstract SG representation through LLMs. Additionally, the predicted SG is explored for its potential in guiding ultrasound scanning toward missing anatomies within the current imaging view, assisting ordinary users in achieving more standardized and complete anatomical exploration. The effectiveness of this SG-based image explanation and scanning guidance has been validated on images from the left and right neck regions, including the carotid and thyroid, across five volunteers. The results demonstrate the potential of the method to maximally democratize ultrasound by enhancing its interpretability and usability for ordinaries.

cs.CV

Deep Reinforcement Learning-Based Control for Stomach Coverage Scanning of Wireless Capsule Endoscopy

Due to its non-invasive and painless characteristics, wireless capsule endoscopy has become the new gold standard for assessing gastrointestinal disorders. Omissions, however, could occur throughout the examination since controlling capsule endoscope can be challenging. In this work, we control the magnetic capsule endoscope for the coverage scanning task in the stomach based on reinforcement learning so that the capsule can comprehensively scan every corner of the stomach. We apply a well-made virtual platform named VR-Caps to simulate the process of stomach coverage scanning with a capsule endoscope model. We utilize and compare two deep reinforcement learning algorithms, the Proximal Policy Optimization (PPO) and Soft Actor-Critic (SAC) algorithms, to train the permanent magnetic agent, which actuates the capsule endoscope directly via magnetic fields and then optimizes the scanning efficiency of stomach coverage. We analyze the pros and cons of the two algorithms with different hyperparameters and achieve a coverage rate of 98.04% of the stomach area within 150.37 seconds.

cs.RO