Searcharxiv⌕ Search

arXiv subjects

Yanchong Xue

Publications and source records attributed to Yanchong Xue.

2 recordsLinked to original sources

Instance-preserving graded semantic reporting for surgical action triplets

Complete-or-reject reporting of surgical action triplets can discard a correctly identified instrument and action when the target is uncertain. We introduce instance-preserving graded semantic reporting, which separates instance selection from the choice of semantic detail. Each selected instance retains its predicted mask and labels while hierarchical correctness scores guide instrument (I), instrument-verb (IV), or complete instrument-verb-target (IVT) reporting. The utility-increment rule DELTA weighs the expected gain from finer reporting against its error cost. We compare three decision rules on 5,641 test frames from eight surgical videos using fixed predictions and scores. At the 10% development calibration target, DELTA retains correct partial reports for 80.0% of candidates rejected by a matched complete-or-reject baseline (5,329/6,662). Adding IV increases source-normalized weighted correct-report yield by 19.13 to 23.13 per 100 frames across all three rules relative to separately recalibrated I/IVT controls. Weighted reporting risk changes by -0.77 to +1.01 percentage points, with complete correct-triplet counts unchanged or reduced. Graded reporting makes partial surgical predictions available as localized descriptions, with an explicit trade-off between report utility and completeness.

cs.CV↗

Selective Surgical Action-Center Localization:Retaining Localization Gains through Supervised Scoring

Surgical action-center localization requires both an accurate reference point and a decision about whether to report it. When frames with and without a reportable center are mixed, the benefit of improved localization depends on which correct candidates survive selection. We present a selective localization pipeline combining heatmap and coordinate supervision with a logistic-regression scorer. The scorer learns to identify predictions with a reportable center and a localization error within a specified tolerance. The internal evaluation uses 5,000 frames from 50 surgical sources, five source-grouped folds and two random seeds. Matched locator and scoring comparisons track correct candidates and their rejection. At an 80% acceptance quota per source and a tolerance of 0.10 times the image diagonal, our method retains 46.08 correct outputs per 100 inputs. The baseline locator with the same scoring approach retains 44.20. The gain is 1.88 (descriptive 95% source-paired bootstrap interval, 0.94 to 2.79). Under entropy-based selection, increased rejection of correct predictions offsets the higher supply of correct predictions on average. For the coordinate-supervised locator, supervised scoring reduces these rejections from 6.15 to 2.99 per 100 inputs. Evaluating retained correct outputs reveals whether a selection rule preserves or erodes an improvement in localization.

cs.CV↗