SearcharxivSearch

arXiv subjects

Yanguo Li

Publications and source records attributed to Yanguo Li.

7 recordsLinked to original sources

The performance of SiPM-based gamma-ray detector (GRD) of GECAM-C

As a new member of GECAM mission, the GECAM-C (also called High Energy Burst Searcher, HEBS) is a gamma-ray all-sky monitor onboard SATech-01 satellite, which was launched on July 27th, 2022 to detect gamma-ray transients from 6 keV to 6 MeV, such as Gamma-Ray Bursts (GRBs), high energy counterpart of Gravitational Waves (GWs) and Fast Radio Bursts (FRBs), and Soft Gamma-ray Repeaters (SGRs). Together with GECAM-A and GECAM-B launched in December 2020, GECAM-C will greatly improve the monitoring coverage, localization, as well as temporal and spectral measurements of gamma-ray transients. GECAM-C employs 12 SiPM-based Gamma-Ray Detectors (GRDs) to detect gamma-ray transients . In this paper, we firstly give a brief description of the design of GECAM-C GRDs, and then focus on the on-ground tests and in-flight performance of GRDs. We also did the comparison study of the SiPM in-flight performance between GECAM-C and GECAM-B. The results show GECAM-C GRD works as expected and is ready to make scientific observations.

astro-ph.IM

Gain stabilization and consistency correction approach for multiple SiPM-based gamma-ray detectors on GECAM

Each satellite of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM, mission) consists of 25 SiPM based gamma-ray detectors (GRDs). Although SiPM based GRD has merits of compact size and low bias-voltage, the drift of the SiPM gain with temperature is a severe problem for GRD performance. An adaptive voltage supply source was designed to automatically adjust the SiPM bias voltage to compensate the temperature effects and keep the gain stable. This approach has been proved to be effective during both the on-ground and in-flight tests. The in-flight measured variation of the SiPM gain is within 2%. To reduce the gain non-uniformity of GRDs, an iterative bias voltage adjustment approach is proposed and implemented. The gain non-uniformity is reduced from 17% to 0.6%. In this paper, the gain stabilization and consistency correction approach are presented and discussed in detail.

physics.ins-det

Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070

A black hole X-ray binary produces hard X-ray radiation from its corona and disk when the accreting matter heats up. During an outburst, the disk and corona co-evolves with each other. However, such an evolution is still unclear in both its geometry and dynamics. Here we report the unusual decrease of the reflection fraction in MAXI J1820+070, which is the ratio of the coronal intensity illuminating the disk to the coronal intensity reaching the observer, as the corona is observed to contrast during the decay phase. We postulate a jet-like corona model, in which the corona can be understood as a standing shock where the material flowing through. In this dynamical scenario, the decrease of the reflection fraction is a signature of the corona's bulk velocity. Our findings suggest that as the corona is observed to get closer to the black hole, the coronal material might be outflowing faster.

astro-ph.HE

Insight-HXMT observations of Swift J0243.6+6124 during its 2017-2018 outburst

The recently discovered neutron star transient Swift J0243.6+6124 has been monitored by {\it the Hard X-ray Modulation Telescope} ({\it Insight-\rm HXMT). Based on the obtained data, we investigate the broadband spectrum of the source throughout the outburst. We estimate the broadband flux of the source and search for possible cyclotron line in the broadband spectrum. No evidence of line-like features is, however, found up to $\rm 150~keV$. In the absence of any cyclotron line in its energy spectrum, we estimate the magnetic field of the source based on the observed spin evolution of the neutron star by applying two accretion torque models. In both cases, we get consistent results with $B\rm \sim 10^{13}~G$, $D\rm \sim 6~kpc$ and peak luminosity of $\rm >10^{39}~erg~s^{-1}$ which makes the source the first Galactic ultraluminous X-ray source hosting a neutron star.

astro-ph.HE

A novel analog power supply for gain control of the Multi-Pixel Photon Counter (MPPC)

Silicon Photo-Multipliers (SiPM) are regarded as novel photo-detectors to replace conventional Photo-Multiplier Tubes (PMTs). However, the breakdown voltage dependence on the ambient temperature results in a gain variation of $\sim$3$\% /^{\circ} \mathrm C$. This severely limits the application of this device in experiments with wide range of operating temperature, especially in space missions. An experimental setup was established to investigate the temperature and bias voltage dependence of gain for the Multi-Pixel Photon Counter (MPPC). The gain and breakdown voltage dependence on operating temperature of an MPPC can be approximated by a linear function, which is similar to the behavior of a zener diode. The measured temperature coefficient of the breakdown voltage is $(59.4 \pm 0.4$ mV)$/^{\circ} \mathrm C$. According to this fact, an analog power supply based on two zener diodes and an operational amplifier was designed with a positive temperature coefficient. The measured temperature dependence for the designed power supply is between 63.65 to 64.61~mV/$^{\circ} \mathrm C$ at different output voltages. The designed power supply can bias the MPPC at an over-voltage with a temperature variation of $\sim$ 5~mV$/^{\circ} \mathrm C$. The gain variation of the MPPC biased at over-voltage of 2~V was reduced from 2.8$\% /^{\circ} \mathrm C$ to 0.3$\% /^{\circ} \mathrm C$ when biased the MPPC with the designed power supply for gain control. Detailed design and performance of the analog power supply in the temperature range from -42.7$^{\circ}\mathrm{C}$ to 20.9$^{\circ}\mathrm{C}$ will be discussed in this paper.

astro-ph.IM

SVOM Gamma Ray Monitor

The Space-based multi-band astronomical Variable Object Monitor (SVOM) mission is dedicated to the detection, localization and broad-band study of Gamma-Ray Bursts (GRBs) and other high-energy transient phenomena. The Gamma Ray Monitor (GRM) onboard is designed to observe the GRBs up to 5 MeV. With this instrument one of the key GRB parameter, Epeak, can be easily measured in the hard x-ray band. It can achieve a detection rate of 100 GRBs per year which ensures the scientific output of SVOM.

astro-ph.IM

Light collection of POLAR detector

POLAR is a compact polarimeter dedicated to measure the polarization of GRBs between 50-300 keV. The light collection of 200*6*6mm3 plastic bars has been simulated and optimized in order to get uniform response to x-rays at different points of one single bar. According to the Monte Carlo results, the amplitude uniformity strongly depends on the polishing level of scintillator surface and the covering. A uniformity of 89% is achieved with a prototype constructed by a non position-sensitive PMT and an array of 4X4 bars.

astro-ph.IM