Searcharxiv⌕ Search

arXiv subjects

Yanlin Wu

Publications and source records attributed to Yanlin Wu.

14 recordsLinked to original sources

4K Image Super-Resolution on Mobile NPUs: Mobile AI 2026 Challenge Report

Image super-resolution is widely used on mobile devices for upscaling various types of image data. This creates a need for efficient deep learning-based models that are not only performant but can also be deployed on neural processing units (NPUs) present in the majority of mobile and IoT chipsets. In this Mobile AI challenge, we address this problem and propose the participants to design fast solutions that can upsample images from Full HD to 4K resolution while running on popular mobile NPUs from Qualcomm and MediaTek. For this, the participants were provided with the DIV2K dataset and trained models to do an efficient 3X image upscaling. The competition had two tracks: in the first track, the models had to be fully quantized (INT8), and the runtime of all models was evaluated on the Qualcomm Snapdragon 8 Elite Gen 5 NPU. In the second track, the participants were developing floating-point solutions that were evaluated on the MediaTek Dimensity 9500 NPU. Top solutions proposed in this challenge are able to reconstruct 4K images under 5 milliseconds while reaching a PSNR score of 30 dB. A comprehensive description of the models developed in the challenge is provided in this paper.

cs.CV↗

BIRD: Distilling Decision Boundaries into Rationales for MLLM Adaptation

Adapting general-purpose multimodal large language models (MLLMs) to specialized domains requires learning domain-specific decision criteria, which often hinge on subtle visual distinctions between otherwise plausible answers. Rationale augmentation aims to expose such evidence through additional observations or inter-sample comparisons, yet a visually valid cue is not necessarily decision-relevant: it may describe how samples differ without changing the model's relative preference between competing answers. We therefore introduce BIRD, a self-improving Boundary-Informed Rationale Distillation framework that uses model-specific confusions to locate unresolved local decision boundaries and distills the evidence that resolves these confusions into rationales. For each sample, BIRD retrieves candidate neighbors from the target MLLM's own representation space and selects the most confusable one according to its answer preferences. It then generates answer-blind candidate evidence from their visual differences and functionally verifies which evidence most effectively strengthens the model's preference for the correct answer while avoiding inappropriate transfer across the pair. The verified evidence is then distilled into a single-sample rationale for standard supervised fine-tuning. Experiments on medical and chart VQA show that BIRD outperforms competing rationale-augmentation methods across two target MLLMs, while further analyses demonstrate clearer separation of confusable answers and stronger gains from model-matched supervision.

cs.AI↗

CFCH: Coarse-Fine Collaborative Hierarchical Learning for Anterior Segment Disease Analysis

Accurate classification of anterior segment diseases is crucial for ophthalmic screening and diagnosis. However, slit-lamp image analysis remains challenging due to substantial variability in imaging conditions and the intrinsic anatomical-disease hierarchy of ocular pathologies. Existing methods typically formulate this task as a flat multi-class classification problem, ignoring the structured dependency between anatomical regions (e.g., cornea, conjunctiva, and lens) and disease manifestations.To address these limitations, we propose CFCH, a Coarse-Fine Collaborative Hierarchical learning framework that explicitly models anatomical context and disease semantics through a dual-branch architecture. To enable effective cross-granularity collaboration, CFCH introduces semantic and cross-granularity attention consistency constraints, encouraging aligned yet complementary feature learning across branches. In addition, we construct AS-9K, a large-scale anterior segment dataset with 8975 images covering 12 common disease categories. To the best of our knowledge, AS-9K is the largest publicly available dataset for anterior segment image classification. Extensive experiments on two anterior segment datasets demonstrate that CFCH outperforms state-of-the-art methods. Qualitative visualizations further show more focused and lesion-relevant activation responses, validating the effectiveness of the proposed framework. Code will be available at https://github.com/ybupengwang/CFCH.

cs.CV↗

Med-URWKV†: Toward Enhanced Pretrained Pure VRWKV Models for Medical Image Segmentation

Medical image segmentation is a fundamental task in computer-aided diagnosis and treatment. Existing approaches based on CNNs, ViTs, Mamba, and hybrid models still suffer from limitations such as restricted receptive fields, high computational cost, or insufficient accuracy. Recently, Vision Receptive-field Weighted Key-Value (VRWKV) models have emerged as a promising alternative,delivering strong long-range dependency modeling for visual tasks. However, current studies on VRWKV-based medical image segmentation mainly focus on hybrid architectures trained from scratch, while the potential of large-scale pretrained pure VRWKV models remains unexplored. In this work, we systematically investigate the effectiveness of pure VRWKV architectures for medical image segmentation. We construct Med-URWKV-T and Med-URWKV-S by reusing pretrained VRWKV encoders at different scales and pairing them with pure VRWKV decoders, enabling a comprehensive evaluation of pretrained pure VRWKV models in this domain. To further enhance performance, we propose two VRWKV-compatible modules: a Frequency-Aware Wavelet Attention (FAWA) module, which exploits wavelet transforms to capture edge details and structural characteristics, and a Multi-Scale Channel Fusion (MSCF) module, which integrates multi-scale features to strengthen informative channel representations. By incorporating them into Med-URWKV-T, we obtain the enhanced model Med-URWKV†. Extensive experiments on five medical image segmentation datasets demonstrate that Med-URWKV achieves performance comparable to or superior to state-of-the-art methods and carefully designed hybrid VRWKV architectures. Moreover, Med-URWKV† further improves segmentation accuracy, surpassing Med-URWKV-S while using only half of its parameter count, and achieves the highest average Dice similarity coefficient of 88.00%. The codes will be released.

eess.IV↗

NTIRE 2026 The 3rd Restore Any Image Model (RAIM) Challenge: AI Flash Portrait (Track 3)

In this paper, we present a comprehensive overview of the NTIRE 2026 3rd Restore Any Image Model (RAIM) challenge, with a specific focus on Track 3: AI Flash Portrait. Despite significant advancements in deep learning for image restoration, existing models still encounter substantial challenges in real-world low-light portrait scenarios. Specifically, they struggle to achieve an optimal balance among noise suppression, detail preservation, and faithful illumination and color reproduction. To bridge this gap, this challenge aims to establish a novel benchmark for real-world low-light portrait restoration. We comprehensively evaluate the proposed algorithms utilizing a hybrid evaluation system that integrates objective quantitative metrics with rigorous subjective assessment protocols. For this competition, we provide a dataset containing 800 groups of real-captured low-light portrait data. Each group consists of a 1K-resolution low-light input image, a 1K ground truth (GT), and a 1K person mask. This challenge has garnered widespread attention from both academia and industry, attracting over 100 participating teams and receiving more than 3,000 valid submissions. This report details the motivation behind the challenge, the dataset construction process, the evaluation metrics, and the various phases of the competition. The released dataset and baseline code for this track are publicly available from the same \href{https://github.com/zsn1434/AI_Flash-BaseLine/tree/main}{GitHub repository}, and the official challenge webpage is hosted on \href{https://www.codabench.org/competitions/12885/}{CodaBench}.

cs.CV↗

DBINDS -- Can Initial Noise from Diffusion Model Inversion Help Reveal AI-Generated Videos?

AI-generated video has advanced rapidly and poses serious challenges to content security and forensic analysis. Existing detectors rely mainly on pixel-level visual cues and generalize poorly to unseen generators. We propose DBINDS, a diffusion-model-inversion based detector that analyzes latent-space dynamics rather than pixels. We find that initial noise sequences recovered by diffusion inversion differ systematically between real and generated videos. Building on this, DBINDS forms an Initial Noise Difference Sequence (INDS) and extracts multi-domain, multi-scale features. With feature optimization and a LightGBM classifier tuned by Bayesian search, DBINDS (trained on a single generator) achieves strong cross-generator performance on GenVidBench, demonstrating good generalization and robustness in limited-data settings.

cs.CV↗

Adaptive Stain Normalization for Cross-Domain Medical Histology

Deep learning advances have revolutionized automated digital pathology analysis. However, differences in staining protocols and imaging conditions can introduce significant color variability. In deep learning, such color inconsistency often reduces performance when deploying models on data acquired under different conditions from the training data, a challenge known as domain shift. Many existing methods attempt to address this problem via color normalization but suffer from several notable drawbacks such as introducing artifacts or requiring careful choice of a template image for stain mapping. To address these limitations, we propose a trainable color normalization model that can be integrated with any backbone network for downstream tasks such as object detection and classification. Based on the physics of the imaging process per the Beer-Lambert law, our model architecture is derived via algorithmic unrolling of a nonnegative matrix factorization (NMF) model to extract stain-invariant structural information from the original pathology images, which serves as input for further processing. Experimentally, we evaluate the method on publicly available pathology datasets and an internally curated collection of malaria blood smears for cross-domain object detection and classification, where our method outperforms many state-of-the-art stain normalization methods. Our code is available at https://github.com/xutianyue/BeerLaNet.

cs.CV↗

TransUKAN:Computing-Efficient Hybrid KAN-Transformer for Enhanced Medical Image Segmentation

U-Net is currently the most widely used architecture for medical image segmentation. Benefiting from its unique encoder-decoder architecture and skip connections, it can effectively extract features from input images to segment target regions. The commonly used U-Net is typically based on convolutional operations or Transformers, modeling the dependencies between local or global information to accomplish medical image analysis tasks. However, convolutional layers, fully connected layers, and attention mechanisms used in this process introduce a significant number of parameters, often requiring the stacking of network layers to model complex nonlinear relationships, which can impact the training process. To address these issues, we propose TransUKAN. Specifically, we have improved the KAN to reduce memory usage and computational load. On this basis, we explored an effective combination of KAN, Transformer, and U-Net structures. This approach enhances the model's capability to capture nonlinear relationships by introducing only a small number of additional parameters and compensates for the Transformer structure's deficiency in local information extraction. We validated TransUKAN on multiple medical image segmentation tasks. Experimental results demonstrate that TransUKAN achieves excellent performance with significantly reduced parameters. The code will be available athttps://github.com/wuyanlin-wyl/TransUKAN.

eess.IV↗

Blockchain-based Federated Recommendation with Incentive Mechanism

Nowadays, federated recommendation technology is rapidly evolving to help multiple organisations share data and train models while meeting user privacy, data security and government regulatory requirements. However, federated recommendation increases customer system costs such as power, computational and communication resources. Besides, federated recommendation systems are also susceptible to model attacks and data poisoning by participating malicious clients. Therefore, most customers are unwilling to participate in federated recommendation without any incentive. To address these problems, we propose a blockchain-based federated recommendation system with incentive mechanism to promote more trustworthy, secure, and efficient federated recommendation service. First, we construct a federated recommendation system based on NeuMF and FedAvg. Then we introduce a reverse auction mechanism to select optimal clients that can maximize the social surplus. Finally, we employ blockchain for on-chain evidence storage of models to ensure the safety of the federated recommendation system. The experimental results show that our proposed incentive mechanism can attract clients with superior training data to engage in the federal recommendation at a lower cost, which can increase the economic benefit of federal recommendation by 54.9\% while improve the recommendation performance. Thus our work provides theoretical and technological support for the construction of a harmonious and healthy ecological environment for the application of federal recommendation.

cs.IR↗

Spatial-Frequency Dual Progressive Attention Network For Medical Image Segmentation

In medical images, various types of lesions often manifest significant differences in their shape and texture. Accurate medical image segmentation demands deep learning models with robust capabilities in multi-scale and boundary feature learning. However, previous networks still have limitations in addressing the above issues. Firstly, previous networks simultaneously fuse multi-level features or employ deep supervision to enhance multi-scale learning. However, this may lead to feature redundancy and excessive computational overhead, which is not conducive to network training and clinical deployment. Secondly, the majority of medical image segmentation networks exclusively learn features in the spatial domain, disregarding the abundant global information in the frequency domain. This results in a bias towards low-frequency components, neglecting crucial high-frequency information. To address these problems, we introduce SF-UNet, a spatial-frequency dual-domain attention network. It comprises two main components: the Multi-scale Progressive Channel Attention (MPCA) block, which progressively extract multi-scale features across adjacent encoder layers, and the lightweight Frequency-Spatial Attention (FSA) block, with only 0.05M parameters, enabling concurrent learning of texture and boundary features from both spatial and frequency domains. We validate the effectiveness of the proposed SF-UNet on three public datasets. Experimental results show that compared to previous state-of-the-art (SOTA) medical image segmentation networks, SF-UNet achieves the best performance, and achieves up to 9.4\% and 10.78\% improvement in DSC and IOU. Codes will be released at https://github.com/nkicsl/SF-UNet.

eess.IV↗

FRCNet Frequency and Region Consistency for Semi-supervised Medical Image Segmentation

Limited labeled data hinder the application of deep learning in medical domain. In clinical practice, there are sufficient unlabeled data that are not effectively used, and semi-supervised learning (SSL) is a promising way for leveraging these unlabeled data. However, existing SSL methods ignore frequency domain and region-level information and it is important for lesion regions located at low frequencies and with significant scale changes. In this paper, we introduce two consistency regularization strategies for semi-supervised medical image segmentation, including frequency domain consistency (FDC) to assist the feature learning in frequency domain and multi-granularity region similarity consistency (MRSC) to perform multi-scale region-level local context information feature learning. With the help of the proposed FDC and MRSC, we can leverage the powerful feature representation capability of them in an effective and efficient way. We perform comprehensive experiments on two datasets, and the results show that our method achieves large performance gains and exceeds other state-of-the-art methods.

cs.CV↗

Byzantine-Tolerant Methods for Distributed Variational Inequalities

Robustness to Byzantine attacks is a necessity for various distributed training scenarios. When the training reduces to the process of solving a minimization problem, Byzantine robustness is relatively well-understood. However, other problem formulations, such as min-max problems or, more generally, variational inequalities, arise in many modern machine learning and, in particular, distributed learning tasks. These problems significantly differ from the standard minimization ones and, therefore, require separate consideration. Nevertheless, only one work (Adibi et al., 2022) addresses this important question in the context of Byzantine robustness. Our work makes a further step in this direction by providing several (provably) Byzantine-robust methods for distributed variational inequality, thoroughly studying their theoretical convergence, removing the limitations of the previous work, and providing numerical comparisons supporting the theoretical findings.

cs.LG↗

The Tianlai dish array low-z surveys forecasts

We present the science case for surveys with the Tianlai dish array interferometer tuned to the $\left[ 1300, 1400 \right] \mathrm{MHz}$ frequency range. Starting from a realistic generation of mock visibility data according to the survey strategy, we reconstruct a map of the sky and perform a foreground subtraction. We show that a survey of the North Celestial Polar cap during a year of observing time and covering an area of $150 \, \mathrm{deg^2}$ would reach a sensitivity of $ 1.5-2 \, \mathrm{mK} $ per $1 \, \mathrm{MHz} \times 0.25^2 \, \mathrm{deg^2 }$ voxel and be marginally impacted by mode-mixing. Tianlai would be able to detect a handful $(\sim 10)$ of nearby massive \HI clumps as well as a very strong cross-correlation signal of 21\,cm intensity maps with the North Celestial Cap Survey optical galaxies. We have also studied the performance of a mid-latitude survey, covering $\sim 1500 \, \mathrm{deg^2}$ centered on a declination of $δ=55^\circ$, which overlaps the Sloan Digital Sky Survey footprint. Despite a higher noise level for the mid-latitude survey, as well as significant distortions due to mode mixing, Tianlai would be able to detect a highly significant cross-correlation between the 21\,cm signal and the Sloan spectroscopic galaxy sample. Using the extragalactic signals from either or both of these surveys, it will be possible to assess the impact of calibration uncertainties, antenna pattern uncertainties, sources of noise, and mode mixing for future surveys requiring higher sensitivity.

astro-ph.CO↗

The Tianlai Dish Pathfinder Array: design, operation and performance of a prototype transit radio interferometer

The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21~cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about $\sim 5 \%$ of 6,200 hours of on-sky observations through October, 2019. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80~K for most feed antennas, and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole, yielded visibilities with amplitudes of 20-30~mK, consistent with the expected signal from the NCP radio sky with $<10\,$mK precision for $1 ~\mathrm{MHz} \times 1~ \mathrm{min}$ binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$mK level.

astro-ph.IM↗