Searcharxiv⌕ Search

arXiv subjects

Yannis K. Semertzidis

Publications and source records attributed to Yannis K. Semertzidis.

At least 37 records · Page 2Linked to original sources

Development of axion haloscopes for high-mass search at CAPP

The axion offers a well-motivated solution to two fundamental questions in modern physics: the strong CP problem and the dark matter mystery. Cavity haloscopes, exploiting resonant enhancement of photon signals, provide the most sensitive searches for axion dark matter in the microwave region. However, current experimental sensitivities are limited to the O(10^0) ueV range, while recent theoretical predictions for the axion mass favor up to O(10^2) ueV, suggesting the need of new experimental approaches that are suitable for higher mass regions. CAPP has developed/proposed several haloscopes effective for high-mass axion searches based on new cavity concepts and practical tuning mechanisms. They are characterized by large detection volumes and/or high quality factors at high frequencies, achieved by partitioning a single cavity into multiple cells, exploiting higher-order resonant modes, and constructing dielectric photonic crystal structures. Improving on the dish antenna haloscope scheme, a horn antenna array has also been proposed for volume-efficient broadband search in the THz region. We review these haloscope designs for sensitive search in the high-mass regions and discuss their impacts on future experiments.

physics.ins-det↗

Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $μ$eV

We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $μ$eV at a 90% confidence level.

hep-ex↗

Expanding Scanning Frequency Range of Josephson Parametric Amplifier Axion Haloscope Readout with Schottky Diode Bias Circuit

The axion search experiments in the microwave frequency range require high sensitive detectors with intrinsic noise close to quantum noise limit. Josephson parametric amplifiers (JPAs) are the most valuable candidates for the role of the first stage amplifier in the measurement circuit of the microwave frequency range, as they are well-known in superconducting quantum circuits readout. To increase the frequency range, a challenging scientific task involves implementing an assembly with parallel connection of several single JPAs, which requires matching the complex RF circuit at microwaves and ensuring proper DC flux bias. In this publication, we present a new DC flux bias setup based on a Schottky diode circuit for a JPA assembly consisting of two JPAs. We provide a detailed characterization of the diodes at cryogenic temperatures lower than 4 K. Specifically, we selected two RF Schottky diodes with desirable characteristics for the DC flux bias setup, and our results demonstrate that the Schottky diode circuit is a promising method for achieving proper DC flux bias in JPA assemblies.

hep-ex↗

Horn-array haloscope for volume-efficient broadband axion searches

The invisible axion is a hypothetical particle that arises from the Peccei-Quinn mechanism proposed to resolve the CP problem in quantum chromodynamics, and is considered one of the most favoured candidates for cold dark matter. Dish antennas can provide a useful scheme for sensitive search for dark matter axions. The conversion power through axion-photon couplings is proportional to the surface area of the metal plate, rather than the volume of the available magnetic field. To maximize the effect, we propose an advanced concept of haloscope that involves an array of horn antennae to increase the axion-induced photons and a reflector to focus them onto a photo sensor. Compared to other proposed schemes, this configuration can significantly improve the experimental sensitivity, especially in the terahertz region.

hep-ph↗

Four-channel System for Characterization of Josephson Parametric Amplifiers

The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz. In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets. The measurements require continuous operation for months without interruptions for microwave component replacements. This is achieved by using different cryogenic engineering approaches including microwave RF-switching. The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology. It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA. In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements. The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements. The setup is placed at 20 mK inside the dry dilution refrigerator. The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables. We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down

cond-mat.supr-con↗

Systematic Approach for Tuning Flux-driven Josephson Parametric Amplifiers for Stochastic Small Signals

Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage. While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the best noise performance. In a typical measurement scheme involving a JPA, one needs to control the resonance frequency, pump frequency and pump power to achieve the desired amplification and noise properties. In this work, we propose a straightforward approach for operating JPAs with the help of a look-up table (LUT) and online fine-tuning. Using the proposed approach, we demonstrate the operation of a flux-driven JPA with 20 dB gain around 5.9 GHz, covering approximately 100 MHz with 20 kHz tuning steps. The proposed methodology was successfully used in the context of a haloscope axion experiment.

physics.ins-det↗

First Search for Axion-Like Particles in a Storage Ring Using a Polarized Deuteron Beam

Based on the notion that the local dark-matter field of axions or axion-like particles (ALPs) in our Galaxy induces oscillating couplings to the spins of nucleons and nuclei (via the electric dipole moment of the latter and/or the paramagnetic axion-wind effect), we establish the feasibility of a new method to search for ALPs in storage rings. Based on previous work that allows us to maintain the in-plane polarization of a stored deuteron beam for a few hundred seconds, we performed a first proof-of-principle experiment at the Cooler Synchrotron COSY to scan momenta near 970 MeV/c. This entailed a scan of the spin precession frequency. At resonance between the spin precession frequency of deuterons and the ALP-induced EDM oscillation frequency there will be an accumulation of the polarization component out of the ring plane. Since the axion frequency is unknown, the momentum of the beam and consequently the spin precession frequency were ramped to search for a vertical polarization change that would occur when the resonance is crossed. At COSY, four beam bunches with different polarization directions were used to make sure that no resonance was missed because of the unknown relative phase between the polarization precession and the axion/ALP field. A frequency window of 1.5-kHz width around the spin precession frequency of 121 kHz was scanned. We describe the experimental procedure and a test of the methodology with the help of a radiofrequency Wien filter located on the COSY ring. No ALP resonance was observed. As a consequence an upper limit of the oscillating EDM component of the deuteron as well as its axion coupling constants are provided.

hep-ex↗

CAPP Axion Search Experiments with Quantum Noise Limited Amplifiers

The axion is expected to solve the strong CP problem of quantum chromodynamics and is one of the leading candidates for dark matter. CAPP in South Korea has several axion search experiments based on cavity haloscopes in the frequency range of 1-6 GHz. The main effort focuses on operation of the experiments with the highest possible sensitivity. It requires maintenance of the haloscopes at the lowest physical temperature in the range of mK and usage of low noise components to amplify the weak axion signal. We report development and operation of low noise amplifiers for 5 haloscope experiments targeting at different frequency ranges. The amplifiers show noise temperatures approaching the quantum limit.

cond-mat.supr-con↗

Josephson Parametric Amplifier in Axion Experiments

The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem. Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature. We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta. In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.

cond-mat.supr-con↗

Axion Dark Matter Search around 4.55 $μ$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity

We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.

hep-ex↗

Speeding axion haloscope experiments using heterodyne-variance-based detection with a power-meter

We describe a new axion search method based on measuring the variance in the interference of the axion signal using injected photons with a power detector. The need for a linear amplifier is eliminated by putting a strong signal into the microwave cavity, to acquire not only the power excess but also measure the variance of the output power. The interference of the external photons with the axion to photon converted signal greatly enhances the variance at the particular axion frequency, providing evidence of its existence. This method has an advantage in that it can always obtain sensitivity near the quantum noise limit even for a power detector with high dark count rate. We describe the basic concept of this method both analytically and numerically, and we show experimental results using a simple demonstration circuit.

physics.ins-det↗

Near-Quantum-Noise Axion Dark Matter Search at CAPP around 9.5 $μ$eV

We report the results of an axion dark matter search over an axion mass range of 9.39-9.51 $μ$eV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-stage scanning method which boosted the scan speed by 26%. As a result, a range of two-photon coupling in a plausible model for the QCD axion was excluded with an order of magnitude higher in sensitivity than existing limits.

hep-ex↗

Analytical considerations for optimal axion haloscope design

The cavity haloscope provides a highly sensitive method to search for dark matter axions in the microwave regime. Experimental attempts to enhance the sensitivity have focused on improving major aspects, such as producing strong magnetic fields, increasing cavity quality factors, and achieving lowest possible noise temperatures. Minor details, however, also need to be carefully considered in realistic experimental designs. They are associated with non-uniform magnetic fields over the detection volume, noise propagation under attenuation and temperature gradients, and thermal disequilibrium in the cavity system. We take analytical approaches to these topics and offer optimal treatments for improved performance.

hep-ex↗

The storage ring proton EDM experiment

We describe a proposal to search for an intrinsic electric dipole moment (EDM) of the proton with a sensitivity of \targetsens, based on the vertical rotation of the polarization of a stored proton beam. The New Physics reach is of order $10^~3$TeV mass scale. Observation of the proton EDM provides the best probe of CP-violation in the Higgs sector, at a level of sensitivity that may be inaccessible to electron-EDM experiments. The improvement in the sensitivity to $θ_{QCD}$, a parameter crucial in axion and axion dark matter physics, is about three orders of magnitude.

hep-ph↗

Physics Opportunities for the Fermilab Booster Replacement

This white paper presents opportunities afforded by the Fermilab Booster Replacement and its various options. Its goal is to inform the design process of the Booster Replacement about the accelerator needs of the various options, allowing the design to be versatile and enable, or leave the door open to, as many options as possible. The physics themes covered by the paper include searches for dark sectors and new opportunities with muons.

hep-ph↗

Analytical Estimations of the Chromaticity and Corrections to the Spin Precession Frequency in Weak Focusing Magnetic Storage Rings

Understanding beam and spin dynamics are fundamental in accelerator physics, and there has been growing interest in having more precise estimations of the beam and spin dynamics variables, as more high precision particle physics experiments in the Intensity Frontier appear. The present paper provides analytical estimations of some of the important variables such as beam transverse chromaticities and the spin precession frequency bias in the simplest type of particle accelerator: a circular magnetic storage ring with weak vertical focusing. We attempt to precisely obtain the next order approximations from the small betatron oscillations or the momentum dispersion, verified by high precision spin tracking simulation. We also discuss a potential way to suppress the spin precession frequency bias which relevant experiments may find beneficial.

physics.acc-ph↗

Search for topological defect dark matter with a global network of optical magnetometers

Ultralight bosons such as axion-like particles are viable candidates for dark matter. They can form stable, macroscopic field configurations in the form of topological defects that could concentrate the dark matter density into many distinct, compact spatial regions that are small compared to the galaxy but much larger than the Earth. Here, we report the results of a search for transient signals from axion-like particle domain walls with the Global Network of Optical Magnetometers for Exotic physics searches (GNOME). We search the data, consisting of correlated measurements from optical atomic magnetometers located in laboratories all over the world, for patterns of signals propagating through the network consistent with domain walls. The analysis of data from a continuous month-long operation of the GNOME finds no statistically significant signals, thus placing experimental constraints on such dark matter scenarios.

astro-ph.CO↗

Comprehensive Symmetric-Hybrid ring design for pEDM experiment at below $10^{-29}e\cdot$cm

A concise demonstrative summary of the Symmetric Hybrid ring design for the storage ring proton electric dipole moment experiment is presented. Critical issues such as lattice design, background electrical fields,geometrical phase, general relativity, spin coherence time and polarimeter systematics are presented. Overall, we find that with the currently proposed design iteration, systematic error sources are reduced by orders of magnitude and that the ring alignment requirements are within the currently available technology.

physics.acc-ph↗