CAPP-8TB: Search for Axion Dark Matter in a Mass Range of 6.62 to 7.04 $μ$eV

The axion is a hypothetical particle proposed to solve the strong $CP$ problem, and also a candidate for dark matter. This non-relativistic particle in the galactic halo can be converted into a photon under a strong magnetic field and detected with a microwave resonant cavity. Relying on this detection method, many experiments have excluded some mass regions with certain sensitivities in terms of axion-photon coupling ($g_{aγγ}$) for decades, but no axion dark matter has been discovered to date. CAPP-8TB is an axion haloscope experiment at IBS/CAPP designed to search for the axion in a mass range of 6.62 to 7.04 $μ$eV. The experiment aims for the most sensitive axion dark matter search in this particular mass range with its first-phase sensitivity reaching the QCD axion band. In this presentation, we discuss the overview of the experiment, and present the first result. We also discuss an upgrade of the experiment to achieve higher sensitivity.

hep-ex↗

Maintaining high Q-factor of superconducting YBa$_2$Cu$_3$O$_{7-x}$ microwave cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be of great use in a wide range of fields, from accelerator design to axion dark matter search. The natural choice of material for the superconducting cavity to be placed in a high field is a high temperature superconductor (HTS) with a high critical field. The deposition, however, of a high-quality, grain-aligned HTS film on a three-dimensional surface is technically challenging. We have fabricated a polygon-shaped resonant cavity with commercial YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) tapes covering the entire inner wall and measured the Q-factor at 4 K at 6.93 GHz as a function of an external DC magnetic field. We demonstrated that the high Q-factor of the superconducting YBCO cavity showed no significant degradation from 1 T up to 8 T. This is the first indication of the possible applications of HTS technology to the research areas requiring a strong magnetic field at high radio frequencies.

physics.ins-det↗

Spin Rotation by Earth's Gravitational Field in a "Frozen-Spin" Ring

Detailed calculations of spin rotation by the Earth's gravitational field in a frozen-spin ring are presented in three different coordinate systems and used (a) to show that the systematic error caused by gravitation in a proposed electric dipole moment measurement can be unambiguously determined, and (b) to propose measuring the spin-gravity effect in a dedicated frozen-spin ring using electrons.

gr-qc↗

High Quality Factor High-Temperature Superconducting Microwave Cavity Development for the Dark Matter Axion Search in a Strong Magnetic Field

We demonstrate a superconducting (SC) microwave (mw) cavity that can accelerate the dark matter search by maintaining superconductivity in a high DC magnetic field. We used high-temperature superconductor (HTSC) yttrium barium copper oxide (YBCO) with a phase transition temperature of 90K to prevent SC failure by the magnetic field. Since the direct deposition of HTSC film on the metallic mw cavity is very difficult, we used the commercial HTSC tapes which are flexible metallic tapes coated with HTSC thin films. We fabricated resonating cavity ($f_{TM010}$ ~ 6.89 GHz) with a third of the inner wall covered by YBCO tapes and measured the quality factor (Q factor) at 4K temperature, varying the DC magnetic field from 0 to 8 tesla. There was no significant quality (Q) factor drop and the superconductivity was well maintained even in 8 tesla magnetic field. This implies the possibility of good performance of HTSC mw resonant cavity under a strong magnetic field for axion detection.

physics.ins-det↗

Effective Approximation of Electromagnetism for Axion Haloscope Searches

We applied an effective approximation into Maxwell's equations with an axion interaction for haloscope searches. A set of Maxwell's equations acquired from this approximation describes just the reacted fields generated by the anomalous interaction. Unlike other approaches, this set of Maxwell's equations inherently satisfies the boundary conditions for haloscope searches. The electromagnetic field solutions from the Maxwell's equations were evaluated for both cylindrical and toroidal cavity geometries including when the axion mass becomes ultra-light (sub-meV). A small but non-zero difference between the electric and magnetic stored energies appeared in both cases. The difference may come from an anomalous non-dissipating current induced by oscillating axions.

hep-ph↗

Comment on "Tunable Supermode Dielectric Resonators for Axion Dark-Matter Haloscopes"

We comment on a recently published paper, Phys. Rev. Applied 9, 014028 (2018), which presents frequency-tuning mechanisms for dielectric resonators and demonstrates their potential application to axion haloscopes. One of the schemes introduces a cylindrical dielectric hollow and splits it in the axial direction to tune the frequency. The authors claim that this scheme offers a 1 to 2-order-of-magnitude improvement in axion search sensitivity in exploiting a higher-order resonant mode. We find that their study is based on unrealistic cavity modeling and inappropriate choice of the figure of merit (FOM), which could mislead to the significant improvement in sensitivity. Considering a practical cavity structure and an appropriate FOM, we recalculate the significance of the scheme, which turns out to be not substantial.

physics.ins-det↗

Magnetic field effects on the proton EDM in a continuous all-electric storage ring

Electric dipole moment of the proton can be searched in an electric storage ring by measuring the spin precession rate of the proton beam on the vertical plane. In the ideal case, the spin precession comes from the coupling between the electric field and the electric dipole moment. In a realistic scenario, the magnetic field becomes a major systematic error source as it couples with the magnetic dipole moment in a similar way. The beam can see the magnetic field in various configurations which include direction, time dependence, etc. For instance, geometric phase effect is observed when the beam sees the field at different directions and phases periodically. We have simulated the effect of the magnetic field in the major independent scenarios and found consistent results with the analytical estimations regarding the static magnetic field cases. We have set a limit for the magnetic field in each scenario and proposed solutions to avoid systematic errors from magnetic fields.

physics.acc-ph↗

A hybrid ring design in the storage-ring proton electric dipole moment experiment

A new, hybrid design is proposed to eliminate the main systematic errors in the frozen spin, storage ring measurement of the proton electric dipole moment. In this design, electric bending plates steer the particles, and magnetic focusing replaces electric. The magnetic focusing should permit simultaneous clock-wise and counter-clock-wise storage to cancel systematic errors related to the out-of-plane dipole electric field. Errors related to the quadrupole electric fields can be eliminated by successive runs of magnetic focusing with different strengths.

physics.acc-ph↗

Axion dark matter search using the storage ring EDM method

We propose using the storage ring EDM method to search for the axion dark matter induced EDM oscillation in nucleons. The method uses a combination of B and E-fields to produce a resonance between the $g-2$ spin precession frequency and the background axion field oscillation to greatly enhance sensitivity to it. An axion frequency range from $10^{-9}$ Hz to 100 MHz can in principle be scanned with high sensitivity, corresponding to an $f_a$ range of $10^{13} $ GeV $\leq f_a \leq 10^{30}$ GeV, the breakdown scale of the global symmetry generating the axion or axion like particles (ALPs).

hep-ex↗

High magnetic fields for fundamental physics

Various fundamental-physics experiments such as measurement of the birefringence of the vacuum, searches for ultralight dark matter (e.g., axions), and precision spectroscopy of complex systems (including exotic atoms containing antimatter constituents) are enabled by high-field magnets. We give an overview of current and future experiments and discuss the state-of-the-art DC- and pulsed-magnet technologies and prospects for future developments.

physics.ins-det↗

Fate of global symmetries in the Universe: QCD axion, quintessential axion and trans-Planckian inflaton decay-constant

Pseudoscalars appearing in particle physics are reviewd systematically. From the fundamental point of view at an ultra-violat completed theory, they can be light if they are realized as pseudo-Goldstone bosons of some spontaneously broken global symmetries. The spontaneous breaking scale is parametrized by the decay constant $f$. The global symmetry is defined by the lowest order terms allowed in the effective theory consistent with the gauge symmetry in question. Since any global symmetry is known to be broken at least by quantum gravitational effects, all pseudoscalars should be massive. The mass scale is determined by $f$ and the explicit breaking terms $ΔV$ in the effective potential and also anomaly terms $ΔΛ^4_G$ for some non-Abelian gauge groups $G$. The well-known example by non-Abelian gauge group breaking is the potential for the "invisible" QCD axion, via the Peccei-Quinn symmetry, which constitutes a major part of this review. Even if there is no breaking terms from gauge anomalies, there can be explicit breaking terms $ΔV$ in the potential in which case the leading term suppressed by $f$ determines the pseudoscalar mass scale. If the breaking term is extremely small and the decay constant is trans-Planckian, the corresponding pseudoscalar can be a candidate for a `quintessential axion'. In general, $(ΔV)^{1/4}$ is considered to be smaller than $f$, and hence the pseudo-Goldstone boson mass scales are considered to be smaller than the decay constants. In such a case, the potential of the pseudo-Goldstone boson at the grand unification scale is sufficiently flat near the top of the potential that it can be a good candidate for an inflationary model, which is known as `natural inflation'. We review all these ideas in the bosonic collective motion framework.

hep-ph↗

Concept of multiple-cell cavity for axion dark matter search

In cavity-based axion dark matter search experiments exploring high mass regions, multiple-cavity design is considered to increase the detection volume within a given magnet bore. We introduce a new idea, referred to as multiple-cell cavity, which provides various benefits including a larger detection volume, simpler experimental setup, and easier phase-matching mechanism. We present the characteristics of this concept and demonstrate the experimental feasibility with an example of a double-cell cavity.

astro-ph.IM↗

Magnetoresistance in copper at high frequency and high magnetic fields

In halo dark matter axion search experiments, cylindrical microwave cavities are typically employed to detect signals from the axion-photon conversion. To enhance the conversion power and reduce the noise level, cavities are placed in strong solenoid magnetic fields at sufficiently low temperatures. Exploring high mass regions in cavity-based axion search experiments requires high frequency microwave cavities and thus understanding cavity properties at high frequencies in extreme conditions is deemed necessary. We present a study of the magnetoresistance of copper using a cavity with a resonant frequency of 12.9 GHz at the liquid helium temperature in magnetic fields up to 15 T utilizing a second generation high temperature superconducting magnet. The observations are interpreted to be consistent with the anomalous skin effect and size effect. This is the first measurement of magnetoresistance at a high frequency (> 10 GHz) in high magnetic fields (> 10 T).

physics.ins-det↗

Systematic errors related to quadrupole misplacement in an all-electric storage ring for proton EDM experiment

Misplacement of electrostatic elements can pose false EDM signal in a storage ring EDM experiment because of coupling between vertical electric field and magnetic dipole moment. A vertically misplaced quadrupole introduces electric field proportional to its misplacement, changing periodically in the particle's rest frame during the storage. This leads to accumulation of vertical spin component at every revolution. We investigated this effect by simulating a proton in an all-electric ring with several quadrupole scenarios. It turns out that the misplacement of quadrupoles is a critical item to keep under control, for which we propose several methods. These include tuning the frequency of the RF cavity, making use of additional correction quadrupoles and using quadrupoles with weaker focusing strength.

physics.acc-ph↗

Correlation of Fe-based Superconductivity and Electron-Phonon Coupling in an FeAs/Oxide Heterostructure

Interfacial phonons between iron-based superconductors (FeSCs) and perovskite substrates have received considerable attention due to the possibility of enhancing preexisting superconductivity. Using scanning tunneling spectroscopy, we studied the correlation between superconductivity and e-ph interaction with interfacial-phonons in an iron-based superconductor Sr$_2$VO$_3$FeAs ($T_c \approx$ 33 K) made of alternating FeSC and oxide layers. The quasiparticle interference measurement over regions with systematically different average superconducting gaps due to the e-ph coupling locally modulated by O vacancies in VO$_2$ layer, and supporting self-consistent momentum-dependent Eliashberg calculations provide a unique real-space evidence of the forward-scattering interfacial phonon contribution to the total superconducting pairing.

cond-mat.supr-con↗

"Higgs" Factory at the Greek-Turkish Border

We would like to propose the construction of the photon collider based "Higgs factory" in the coming years at the Greek-Turkish border, starting from its test facility with a high energy photon beam. This proposal was among the contributions to the Open Symposium of the ESPG'12.

physics.acc-ph↗

A Storage Ring proton Electric Dipole Moment experiment: most sensitive experiment to CP-violation beyond the Standard Model

The Storage Ring EDM Collaboration is completing a comprehensive proposal to DOE for a sensitive proton EDM experiment at the 10-29e\cdot cm level. This involves building an electric ring of radius R~40 m, with bending provided by stainless steel plates separated by 3 cm gap, providing an electric field of 10 MV/m. This ring can store protons of 0.7 GeV/c momentum, also known as "magic" due to the unique property that the spin and momentum vectors precess at the same rate in any electric field. If the spin is kept longitudinal for most of the duration of the storage time, the radial E-field acts on the proton electric dipole moment and can cause a measureable vertical spin precession. Studies on spin coherence time, on the polarimeter system, and the electric field show that we can reach the experimental goals. A plan on the relative beam position monitors uses currently available technology and applies it in an accelerator environment. Some R&D is needed to establish the feasibility of the plan. Prospects of further improvement with a future upgrade for another order of magnitude in the EDM sensitivity are also laid out.

physics.acc-ph↗

Resonance method of electric-dipole-moment measurements in storage rings

A resonance method of measuring the electric dipole moment (EDM) of nuclei in storage rings is described, based on two new ideas: (1) Oscillating particles' velocities in resonance with spin precession, and (2) alternately producing two sub-beams with different betatron tunes--one sub-beam to amplify and thus make it easier to correct ring imperfections that produce false signals imitating EDM signals, and the other to make the EDM measurement.

hep-ex↗