Searcharxiv⌕ Search

arXiv subjects

Yao-Chin Huang

Publications and source records attributed to Yao-Chin Huang.

7 recordsLinked to original sources

Demonstration of length control for a filter cavity with coherent control sidebands

For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique and will be implemented in Advanced LIGO and Advanced Virgo in the fourth observing run. To obtain the benefit of frequency-dependent squeezing, the length and alignment of the filter cavity with respect to the squeezed vacuum field must be accurately controlled. To this purpose, a new length and alignment control scheme for a filter cavity, using coherent control sidebands, was suggested [Phys. Rev. D 102, 042003 (2020)]. The coherent control sidebands are already used to control the squeezing angle in squeezed vacuum sources for gravitational-wave detectors. As both the squeezed vacuum field and coherent control sidebands have the same mode-matching conditions and almost the same frequency, the length and alignment of the filter cavity with respect to the squeezed vacuum field can be accurately controlled with this scheme. In this paper, we experimentally demonstrate the new control scheme for a filter cavity with coherent control sidebands. In addition to the conventional filter cavity control with the green field, we succeed in controlling the length of a 300-m filter cavity with coherent control sidebands and reduce the filter cavity length noise (rms) from 6.8 to 2.1 pm.

physics.ins-det↗

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

physics.ins-det↗

Extract the Degradation Information in Squeezed States with Machine Learning

In order to leverage the full power of quantum noise squeezing with unavoidable decoherence, a complete understanding of the degradation in the purity of squeezed light is demanded. By implementing machine learning architecture with a convolutional neural network, we illustrate a fast, robust, and precise quantum state tomography for continuous variables, through the experimentally measured data generated from the balanced homodyne detectors. Compared with the maximum likelihood estimation method, which suffers from time-consuming and over-fitting problems, a well-trained machine fed with squeezed vacuum and squeezed thermal states can complete the task of reconstruction of the density matrix in less than one second. Moreover, the resulting fidelity remains as high as $0.99$ even when the anti-squeezing level is higher than $20$~dB. Compared with the phase noise and loss mechanisms coupled from the environment and surrounding vacuum, experimentally, the degradation information is unveiled with machine learning for low and high noisy scenarios, i.e., with the anti-squeezing levels at $12$~dB and $18$~dB, respectively. Our neural network enhanced quantum state tomography provides the metrics to give physical descriptions of every feature observed in the quantum state with a single-shot measurement and paves a way of exploring large-scale quantum systems in real-time.

quant-ph↗

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

astro-ph.IM↗

Inverted Ladder Type Optical Excitation of Potassium Rydberg States with Hot and Cold Ensembles

We present experimental results on the sub-Doppler Rydberg spectroscopy of potassium in a hot cell and cold atoms, performed with two counter-propagating laser beams of 405 nm and 980 nm in the inverted ladder-type system (4S1/2-5P3/2-nS1/2 and nD3/2;5/2). Such an inverted ladder-type scheme is predicted to be without sub-Doppler electromagnetically induced transparency (EIT) feature in a thermal ensemble under the weak-probe approximation. Instead, we utilized a strong probe field and successfully observed a transparency window with a width narrower than 50~MHz. Our all-order numerical simulation is in satisfactory agreement with the experimental results. This narrow linewidth allows us to measure the energy levels of the Rydberg levels from $n$=20-70 with improved accuracy. The deduced ionization energy agrees with the previous measurements. Furthermore, the two-photon Rydberg excitation scheme was applied to the cold ensembles to study the ground-state atoms population decrease in the MOT for various Rydberg states. Our experimental observations suggested two distinct regimes of the trap losses under different probe detuning conditions. While the far off-resonance case (δp>>0) can be described by the picture of dressed atom, the on-resonance case (δp~0) reveals more interesting results. The higher Rydberg states suffer larger trap loss. Besides, even with similar level energies, the excitation to nD states result in faster escape of the ground-state atom from trap than nearby nS states.

physics.atm-clus↗

Absolute frequency measurement of molecular iodine hyperfine transitions at 647 nm

We report absolute frequency measurements of the molecular iodine P(46) 5-4 $a_{1}$, $a_{10}$, and $a_{15}$ hyperfine transitions at 647 nm with a fiber-based frequency comb. The light source is based on a Littrow-type external-cavity diode laser. A frequency stability of 5 $\times$ 10$^{-12}$ at a 200 s integration time is achieved when the light source is stabilized to the P(46) 5-4 $a_{15}$ line. The pressure shift is determined to be -8.3(7) kHz/Pa. Our determination of the line centers reached a precision of 21 kHz. The light source can serve as a reference laser for lithium atom spectroscopy ($2P \to 3P$).

physics.atom-ph↗

Precise Frequency Measurement of the 2$^{1}$S$_{0}$-3$^{1}$D$_{2}$ Two-Photon Transition in atomic $^{4}$He

We present the first precise frequency measurement of the 2$^{1}$S$_{0}$-3$^{1}$D$_{2}$ two-photon transition in $^{4}$He at 1009 nm. The laser source at 1009 nm is stabilized on an optical frequency comb to perform the absolute frequency measurement. The absolute frequency of 2$^{1}$S$_{0}$-3$^{1}$D$_{2}$ transition is experimentally determined to be 594 414 291 803(13) kHz with a relative uncertainty of 1.6 $\times$ 10$^{-11}$ which is more precise than previous determination by a factor of 25. Combined with the theoretical ionization energy of the 3$^{1}$D$_{2}$ state, the ionization energy of the 2$^{1}$S$_{0}$ state is determined to be 960 332 040 866(24) kHz. In addition, the deduced 2$^{1}$S$_{0}$ and 2$^{3}$S$_{1}$ Lamb shifts are 2806.817(24) and 4058.8(24) MHz respectively which are 1.6 times better than previous determinations.

physics.atom-ph↗