SearcharxivSearch

arXiv subjects

Yavuz Muslu

Publications and source records attributed to Yavuz Muslu.

5 recordsLinked to original sources

Rapid TAURUS for Relaxation-Based Color Magnetic Particle Imaging

Magnetic particle imaging (MPI) is a rapidly developing medical imaging modality that exploits the non-linear response of magnetic nanoparticles (MNPs). Color MPI widens the functionality of MPI, empowering it with the capability to distinguish different MNPs and/or MNP environments. The system function approach for color MPI relies on extensive calibrations that capture the differences in the harmonic responses of the MNPs. An alternative calibration-free x-space-based method called TAURUS estimates a map of the relaxation time constant, by recovering the underlying mirror symmetry in the MPI signal. However, TAURUS requires a back and forth scanning of a given region, restricting its usage to slow trajectories with constant or piecewise constant focus fields (FFs). In this work, we propose a novel technique to increase the performance of TAURUS and enable $\tau$ map estimation for rapid and multi-dimensional trajectories. The proposed technique is based on correcting the mirror symmetry distortion induced by time-varying FFs. We demonstrate via simulations and experiments in our in-house MPI scanner that the proposed method successfully estimates high-fidelity time constant maps for rapid trajectories that provide orders of magnitude reduction in scanning time while preserving the calibration-free property of TAURUS.

eess.SP

Partial FOV Center Imaging (PCI): A Robust X-Space Image Reconstruction for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality that images the spatial distribution of superparamagnetic iron oxide (SPIO) nanoparticles using their nonlinear response to applied magnetic fields. In standard x-space approach to MPI, the image is reconstructed by gridding the speed-compensated nanoparticle signal to the instantaneous position of the field free point (FFP). However, due to safety limits on the drive field, the field-of-view (FOV) needs to be covered by multiple relatively small partial field-of-views (pFOVs). The image of the entire FOV is then pieced together from individually processed pFOVs. These processing steps can be sensitive to non-ideal signal conditions such as harmonic interference, noise, and relaxation effects. In this work, we propose a robust x-space reconstruction technique, Partial FOV Center Imaging (PCI), with substantially simplified pFOV processing. PCI first forms a raw image of the entire FOV by mapping MPI signal directly to pFOV center locations. The corresponding MPI image is then obtained by deconvolving this raw image by a fully known, compact kernel, which solely depends on the pFOV size. We analyze the performance of the proposed reconstruction via extensive simulations, as well as imaging experiments on our in-house FFP MPI scanner. The results show that PCI offers a trade-off between noise robustness and interference robustness, outperforming standard x-space reconstruction in terms of both robustness against non-ideal signal conditions and image quality.

physics.med-ph

Calibration-Free Relaxation-Based Multi-Color Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is a novel imaging modality with important applications such as angiography, stem cell tracking, and cancer imaging. Recently, there have been efforts to increase the functionality of MPI via multi-color imaging methods that can distinguish the responses of different nanoparticles, or nanoparticles in different environmental conditions. The proposed techniques typically rely on extensive calibrations that capture the differences in the harmonic responses of the nanoparticles. In this work, we propose a method to directly estimate the relaxation time constant of the nanoparticles from the MPI signal, which is then used to generate a multi-color relaxation map. The technique is based on the underlying mirror symmetry of the adiabatic MPI signal when the same region is scanned back and forth. We validate the proposed method via extensive simulations, and via experiments on our in-house Magnetic Particle Spectrometer (MPS) setup at 550 Hz and our in-house MPI scanner at 9.7 kHz. Our results show that nanoparticles can be successfully distinguished with the proposed technique, without any calibration or prior knowledge about the nanoparticles.

physics.med-ph

A Blind Deconvolution Technique Based on Projection Onto Convex Sets for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging imaging modality that maps the spatial distribution of magnetic nanoparticles. The x-space reconstruction in MPI results in highly blurry images, where the resolution depends on both system parameters and nanoparticle type. Previous techniques to counteract this blurring rely on the knowledge of the imaging point spread function (PSF), which may not be available or may require additional measurements. This work proposes a blind deconvolution algorithm for MPI to recover the precise spatial distribution of nanoparticles. The proposed algorithm exploits the observation that the imaging PSF in MPI has zero phase in Fourier domain. Thus, even though the reconstructed images are highly blurred, phase remains unaltered. We leverage this powerful property to iteratively enforce consistency of phase and bounded l1 energy information, using an orthogonal Projections Onto Convex Sets (POCS) algorithm. To demonstrate the method, comprehensive simulations were performed without and with nanoparticle relaxation effects, and at various noise levels. In addition, imaging experiments were performed on an in-house MPI scanner using a three-vial phantom that contained different nanoparticle types. Image quality was compared with conventional deconvolution methods, Wiener deconvolution and Lucy-Richardson method, which explicitly rely on the knowledge of PSF. Both the simulation results and experimental imaging results show that the proposed blind deconvolution algorithm outperforms the conventional deconvolution methods. Without utilizing the imaging PSF, the proposed algorithm improves image quality and resolution even in the case of different nanoparticle types, while displaying reliable performance against loss of the fundamental harmonic, nanoparticle relaxation effects, and noise.

physics.med-ph

Relaxation-based viscosity mapping for magnetic particle imaging

Magnetic Particle Imaging (MPI) has been shown to provide remarkable contrast for imaging applications such as angiography, stem cell tracking, and cancer imaging. Recently, there is growing interest in the functional imaging capabilities of MPI, where color MPI techniques have explored separating different nanoparticles, which could potentially be used to distinguish nanoparticles in different states or environments. Viscosity mapping is a promising functional imaging application for MPI, as increased viscosity levels in vivo have been associated with numerous diseases such as hypertension, atherosclerosis, and cancer. In this work, we propose a viscosity mapping technique for MPI through the estimation of the relaxation time constant of the nanoparticles. Importantly, the proposed time constant estimation scheme does not require any prior information regarding the nanoparticles. We validate this method with extensive experiments in an in-house magnetic particle spectroscopy (MPS) setup at four different frequencies (between 250 Hz and 10.8 kHz) and at three different field strengths (between 5 mT and 15 mT) for viscosities ranging between 0.89 mPa.s to 15.33 mPa.s. Our results demonstrate the viscosity mapping ability of MPI in the biologically relevant viscosity range.

physics.med-ph