SearcharxivSearch

arXiv subjects

Yen-Peng Liao

Publications and source records attributed to Yen-Peng Liao.

2 recordsLinked to original sources

An integrated diffusion-weighted imaging processing and interpretation platform for MR-guided radiotherapy

Background: Magnetic resonance imaging-guided linear accelerators (MR-Linacs) allow diffusion-weighted imaging (DWI) to be acquired at every treatment fraction, but converting these low-signal-to-noise-ratio acquisitions into clinical decisions requires both reliable quantitative processing and an interpretation that reconciles a scattered and often contradictory literature. Purpose: To describe and evaluate an integrated, web-based platform that carries raw MR-Linac DWI to a structured, literature-grounded clinical interpretation, and to assess its retrieval-augmented generation (RAG) interpretation module by independent expert rating. Methods: The platform couples a deep-learning processing pipeline, comprising distortion correction, denoising, and intravoxel incoherent motion (IVIM)/apparent diffusion coefficient (ADC) fitting, with longitudinal region-of-interest analysis and a RAG interpretation agent. The agent reasons over a two-layer knowledge base of curated publications (a structured catalog index plus line-indexed full text), delegates arithmetic to deterministic tools, and is designed to trace each statement to a source document, section, and line range. One medical physicist and one physician independently rated the agent's reports for nine longitudinal glioblastoma cases on a 1-5 scale across three metrics: clinical-reasoning soundness, literature-citation quality, and overall clinical utility. Results: Across 54 ratings, the pooled mean was 4.65 +/- 0.80, with 93% of ratings >= 4; metric means were 4.6 (reasoning), 4.5 (citation), and 4.8 (utility), and raters agreed within one point on 85% of paired ratings. Conclusions: A single platform can integrate MR-Linac DWI post-processing with traceable, expert-evaluated clinical interpretation, while highlighting the safeguards needed to verify LLM-generated reasoning in radiation oncology.

physics.med-ph

Joint k-TE Space Image Reconstruction and Data Fitting for T2 Mapping

Objectives: To develop a joint k-TE reconstruction algorithm to reconstruct the T2-weighted (T2W) images and T2 map simultaneously. Materials and Methods: The joint k-TE reconstruction model was formulated as an optimization problem subject to a self-consistency condition of the exponential decay relationship between the T2W images and T2 map. The objective function included a data fidelity term enforcing the agreement between the solution and the measured k-space data, together with a spatial regularization term on image properties of the T2W images. The optimization problem was solved using Alternating-Direction Method of Multipliers (ADMM). We tested the joint k-TE method in phantom data and healthy volunteer scans with fully-sampled and under-sampled k-space lines. Image quality of the reconstructed T2W images and T2 map, and the accuracy of T2 measurements derived by the joint k- TE and the conventional signal fitting method were compared. Results: The proposed method improved image quality with reduced noise and less artifacts on both T2W images and T2 map, and increased measurement consistency in T2 relaxation time measurements compared with the conventional method in all data sets. Conclusions: The proposed reconstruction method outperformed the conventional magnitude image-based signal fitting method in image quality and stability of quantitative T2 measurements

physics.med-ph