SearcharxivSearch

arXiv subjects

Yeongduk Kim

Publications and source records attributed to Yeongduk Kim.

13 recordsLinked to original sources

Development and Initial Performance of an Upgraded NaI(Tl) Crystal Encapsulation for COSINE-100U

The COSINE-100 experiment was designed to test the DAMA/LIBRA annual-modulation claim using low-background NaI(Tl) detectors. For the COSINE-100U upgrade, we developed a new crystal-encapsulation system to increase light-collection efficiency while preserving long-term detector stability, thereby improving sensitivity to low-mass dark matter. The upgraded design eliminates the quartz optical windows used in COSINE-100 and directly couples the photomultiplier tubes (PMTs) to the crystal end faces through 2-mm-thick silicone optical pads, thereby reducing the number of optical interfaces. For the larger crystals, the crystal edges were beveled to guide scintillation light more efficiently onto 3-inch high-quantum-efficiency PMTs. The performance study uses 2462~h (102.6~days) of room-temperature COSINE-100U data and, for direct background comparisons, reference COSINE-100 data acquired near the end of operation. 698~h (29.1~days) of COSINE-100 data acquired near the end of operation in March 2023. All eight crystals showed higher light yields than in COSINE-100, with values ranging from 15.8 to 27.7~p.e./keV; six crystals exceeded 20~p.e./keV. The measured bulk-$α$ rates were lower than the COSINE-100 values and consistent with the expected time evolution of internal $^{210}$Pb, while the 1--2-MeV surface-$α$ rates were substantially reduced. The upgrade also restored two crystals that had previously been excluded from the COSINE-100 physics analysis because of poor optical performance. Independent validation tests demonstrated that the encapsulation remains mechanically robust and optically stable during long-term immersion in liquid scintillator at low temperature. This paper presents the encapsulation design, the room-temperature detector performance, and the reduction in surface-related backgrounds achieved at the Yemilab facility.

physics.ins-det

Neutron spectrum measurement in the Yemi underground laboratory

We report on the measurement of neutron energy spectra at the newly established Yemi Underground Laboratory (Yemilab) in the Republic of Korea, designed to host dark matter and rare-event search experiments. A high-sensitivity neutron spectrometer was employed, consisting of ten cylindrical {}^{3}He proportional counters, eight of which were embedded in cylindrical high-density polyethylene moderators of various sizes. To quantify and mitigate contributions from internal α-backgrounds, each detector underwent a dedicated background measurement using a cadmium-shielded box. These backgrounds, primarily originating from trace amounts of U and Th in the stainless-steel housings, were characterized and subtracted during data analysis. Neutron measurements were carried out at three locations within the Yemilab between March to October 2023. After waveform-based event selection and correction for \alphasym-backgrounds, neutron count rates were estimated and corresponding energy spectra were reconstructed using the unfolding method. The total neutron fluence rates were measured ranged from (3.24 $\pm$ 0.11) to (4.01 $\pm$ 0.10) $\times~10^{-5}~ {cm}^{-2}~{s}^{-1}$, with thermal and fast neutron components (1 - 10 MeV) ranging from (1.32 $\pm$ 0.05) to (1.51 $\pm$ 0.05) $\times 10^{-5}~{cm}^{-2}~{s}^{-1}$ and (0.27 $\pm$ 0.03) to (0.34 $\pm$ 0.10) $\times~10^{-5}~{cm}^{-2}~{s}^{-1}$, respectively.

physics.ins-det

New Constraints on Axion-Like Particles with the NEON Detector at a Nuclear Reactor

We report new constraints on axion-like particles (ALPs) using data from the NEON experiment, which features a 16.7 kg of NaI(Tl) target located 23.7 meters from a 2.8 GW thermal power nuclear reactor. Analyzing a total exposure of 3063 kg$\cdot$days, with 1596 kg$\cdot$days during reactor-on and 1467 kg$\cdot$days during reactor-off periods, we compared energy spectra to search for ALP-induced signals. No significant signal was observed, enabling us to set exclusion limits at the 95\% confidence level. These limits probe previously unexplored regions of the ALP parameter space, particularly for axion mass ($m_a$) near $1$ MeV/c$^2$. For ALP-photon coupling (${g_{aγ}}$), limits reach as low as 6.24$\times$ 10$^{-6}$ GeV$^{-1}$ at $m_a$ = 3.0 MeV/c$^2$, while for ALP-electron coupling (${g_{ae}}$), limits reach 4.95$\times$ 10$^{-8}$ at $m_a$ = 1.02 MeV/c$^2$. This work demonstrates the potential for future reactor experiments to probe unexplored ALP parameter space.

hep-ex

Radon Concentration Measurement with a High-Sensitivity Radon Detector at the Yemilab

The radiation emitted from radon is a critical background in rare event search experiments conducted at the Yemi Underground Laboratory (Yemilab) in Jeongseon, Korea. A Radon Reduction System(RRS) has been developed and installed in Yemilab to reduce radon concentration in the air. The RRS primarily provides a purified air of 50 m3/h to the cleanroom used to assemble crystal detectors in the AMoRE, a neutrinoless double beta decay search experiment. RRS can reduce the radon level by a factor of 300, so a high-sensitivity radon detector was required. A highly sensitive radon detector was constructed using a 70 L chamber with a large PIN photodiode to measure radon concentration in the purified air. The radon detector shows an excellent resolution of 72 keV (FWHM) for 6.003 MeV alphas from 218Po decay and a sensitivity down to 23.8 +- 2.1 mBq/m3 with a boil-off N2 gas sample. The radon concentration level from the RRS measured by the radon detector was below 0.29 Bq/m3 with a reduction factor of about 300.

physics.ins-det

New targets for relic antineutrino capture

$^{163}$Ho has been considered as a suitable candidate for the capture of relic antineutrinos. However, the detection of the relic antineutrino using $^{163}$Ho is extremely challenging with current techniques. Therefore, we have searched for new targets for relic antineutrino detections through the resonant capture on nuclides undergoing electron capture. We have investigated nuclear and atomic properties of all nuclides. And we finally propose $^{131}$Ba, $^{159}$Dy, $^{175}$Hf, $^{195}$Au, and $^{243}$Cm as new candidates for the relic antineutrino detection, and call for high precise experiments of $Q_{\rm EC}$-values and intensities of EC decays for these new candidates.

hep-ph

Mass production of ultra-pure NaI powder for COSINE-200

COSINE-200 is the next phase experiment of the ongoing COSINE-100 that aims to unambiguously verify the annual modulation signals observed by the DAMA experiment and to reach the world competitive sensitivity on the low-mass dark matter search. To achieve the physics goal of the COSINE-200, the successful production of the low-background NaI(Tl) detectors is crucial and it must begin from the mass production of the ultra-low background NaI powder. A clean facility for mass-producing the pure-NaI powder has been constructed at the Center for Underground Physics (CUP) in Korea. Two years of operation determined efficient parameters of the mass purification and provided a total of 480 kg of the ultra-pure NaI powder in hand. The potassium concentration in the produced powders varied from 5.4 to 11 ppb, and the maximum production capacity of 35 kg per two weeks was achieved. Here, we report our operational practice with the mass purification of the NaI powder, which includes raw powder purification, recycling of the mother solution, and recovery of NaI from the residual melt that remained after crystal growth.

physics.ins-det

IsoDAR@Yemilab: A Report on the Technology, Capabilities, and Deployment

IsoDAR@Yemilab is a novel isotope-decay-at-rest experiment that has preliminary approval to run at the Yemi underground laboratory (Yemilab) in Jeongseon-gun, South Korea. In this technical report, we describe in detail the considerations for installing this compact particle accelerator and neutrino target system at the Yemilab underground facility. Specifically, we describe the caverns being prepared for IsoDAR, and address installation, hielding, and utilities requirements. To give context and for completeness, we also briefly describe the physics opportunities of the IsoDAR neutrino source when paired with the Liquid Scintillator Counter (LSC) at Yemilab, and review the technical design of the neutrino source.

physics.ins-det

Dark Photon Search at Yemilab, Korea

Dark photons are well motivated hypothetical dark sector particles that could account for observations that cannot be explained by the standard model of particle physics. A search for dark photons that are produced by an electron beam striking a thick tungsten target and subsequently interact in a 3 kiloton-scale neutrino detector in Yemilab, a new underground lab in Korea, is proposed. Dark photons can be produced by "darkstrahlung" or by oscillations from ordinary photons produced in the target and detected by their visible decays, "absorption" or by their oscillation to ordinary photons. By detecting the absorption process or the oscillation-produced photons, a world's best sensitivity for measurements of the dark-photon kinetic mixing parameter of $ε^2 > 1.5 \times 10^{-13} (6.1 \times 10^{-13})$ at the 95\% confidence level (C.L.) could be obtained for dark photon masses between 80 eV and 1 MeV in a year-long exposure to a 100 MeV-100 kW electron beam with zero ($10^3$) background events. In parallel, the detection of $e^+e^-$ pairs from decays of dark photons with mass between 1 MeV and $\sim$86 MeV would have sensitivities of $ε^2 > \mathcal{O}(10^{-17}) (\mathcal{O}(10^{-16}))$ at the 95% C.L. with zero ($10^3$) background events.

hep-ph

A facility for mass production of ultra-pure NaI powder for the COSINE-200 experiment

COSINE-200 is the next phase of the ongoing COSINE-100 experiment. The main purpose of the experiment is the performance of an unambiguous verification of the annual modulation signals observed by the DAMA experiment. The success of the experiment critically depends on the production of a 200 kg array of ultra-pure NaI(Tl) crystal detectors that have lower backgrounds than the DAMA crystals. The purification of raw powder is the initial but important step toward the production of ultra-pure NaI(Tl) detectors. We have already demonstrated that fractional recrystallization from water solutions is an effective method for the removal of the problematic K and Pb elements. For the mass production of purified powder, a clean facility for the fractional recrystallization had been constructed at the Institute for Basic Science (IBS), Korea. Here, we report the design of the purification process, material recovery, and performance of the NaI powder purification facility.

physics.ins-det

Neutrino-based tools for nuclear verification and diplomacy in North Korea

We present neutrino-based options for verifying that the nuclear reactors at North Korea's Yongbyon Nuclear Research Center are no longer operating or that they are operating in an agreed manner, precluding weapons production. Neutrino detectors may be a mutually agreeable complement to traditional verification protocols because they do not require access inside reactor buildings, could be installed collaboratively, and provide persistent and specific observations. At Yongbyon, neutrino detectors could passively verify reactor shutdowns or monitor power levels and plutonium contents, all from outside the reactor buildings. The monitoring options presented here build on recent successes in basic particle physics. Following a dedicated design study, these tools could be deployed in as little as one year at a reasonable cost. In North Korea, cooperative deployment of neutrino detectors could help redirect a limited number of scientists and engineers from military applications to peaceful technical work in an international community. Opportunities for scientific collaboration with South Korea are especially strong. We encourage policymakers to consider collaborative neutrino projects within a broader program of action toward stability and security on the Korean Peninsula.

physics.soc-ph

An experiment to search for dark matter interactions using sodium iodide detectors

Observations of galaxies and primordial radiation suggest that the Universe is made mostly of non-luminous dark matter. Several types of new fundamental particles have been proposed as candidates for dark matter such as weakly interacting massive particles (WIMPs) but no definitive signal has been seen despite concerted efforts by many collaborations. One exception is the much-debated claim by the DAMA collaboration of a statistically significant annual modulation in the event rate of their experiment with a period and phase consistent with that expected from WIMP dark matter. Several groups have been working to develop experiments with the aim of reproducing DAMA's results using the same target medium. Here we report results from the initial operation of the COSINE-100 experiment. COSINE-100 uses sodium iodide as the target medium-the same medium as DAMA-and is designed to carry out a model-independent test of DAMA's claim. Initial data based on the first 59.5 days indicate that there is no excess of events over the expected background, confirming that DAMA's annual modulation signal is in severe tension with results from other experiments under the assumption of dark matter having spin independent interactions and the Standard Halo Model. COSINE-100 is now taking data to study the presence of dark matter-induced annual modulation in the event rate of the sodium iodide detectors.

astro-ph.IM

Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment

A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base solvent of the NEOS detector. Furthermore, a di-isopropylnaphthalene (DIN) is added to improve the light output and pulse shape discrimination (PSD) ability. The ratio of LAB to DIN is 90:10. PPO (3 g/L) and bis-MSB (30 mg/L) are dissolved to formulate the mixture of LAB- and DIN-based liquid scintillator (LS). Then, ~0.5% gadolinium (Gd) is loaded into the LS by using the solvent-solvent extraction technique. In this paper, we report the characteristics of Gd-loaded LS (GdLS) for the NEOS detector and the handling during mass production.

physics.ins-det

A simulation-based study of the neutron backgrounds for NaI dark matter experiments

Among the direct search experiments for weakly interacting massive particle (WIMP) dark matter, the DAMA experiment observed an annual modulation signal interpreted as WIMP interactions with a significance of 9.2$σ$. Recently, Jonathan Davis claimed that the DAMA modulation may be interpreted on the basis of the neutron scattering events induced by the muons and neutrinos together. We tried to simulate the neutron backgrounds at the Gran Sasso and Yangyang laboratory with and without the polyethylene shielding to quantify the effects of the ambient neutrons on the direct detection experiments based on the crystals.

hep-ex