SearcharxivSearch

arXiv subjects

Yihui Lai

Publications and source records attributed to Yihui Lai.

8 recordsLinked to original sources

Recent results on heavy resonances at CMS

The Standard Model (SM) of particle physics provides a successful description of elementary particles and their interactions. However, it does not explain phenomena such as the hierarchy problem or the nature of dark matter. Many Beyond the Standard Model (BSM) theories provide answers to these open questions by adding new heavy resonances, which can be probed directly at colliders. This note summarizes recent resonance searches by the CMS Collaboration, focusing on final states containing top quarks and Higgs bosons.

hep-ex

Studies of Cherenkov Photon Production in PbF$_2$ Crystals using Proton Beams at Fermilab

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. We focus on using PbF2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.

physics.ins-det

Dose rate effects in radiation-induced changes to phenyl-based polymeric scintillators

Results on the effects of ionizing radiation on the signal produced by plastic scintillating rods manufactured by Eljen Technology company are presented for various matrix materials, dopant concentrations, fluors (EJ-200 and EJ-260), anti-oxidant concentrations, scintillator thickness, doses, and dose rates. The light output before and after irradiation is measured using an alpha source and a photomultiplier tube, and the light transmission by a spectrophotometer. Assuming an exponential decrease in the light output with dose, the change in light output is quantified using the exponential dose constant $D$. The $D$ values are similar for primary and secondary doping concentrations of 1 and 2 times, and for antioxidant concentrations of 0, 1, and 2 times, the default manufacturer's concentration. The $D$ value depends approximately linearly on the logarithm of the dose rate for dose rates between 2.2 Gy/hr and 70 Gy/hr for all materials. For EJ-200 polyvinyltoluene-based (PVT) scintillator, the dose constant is approximately linear in the logarithm of the dose rate up to 3400 Gy/hr, while for polystyrene-based (PS) scintillator or for both materials with EJ-260 fluors, it remains constant or decreases (depending on doping concentration) above about 100 Gy/hr. The results from rods of varying thickness and from the different fluors suggest damage to the initial light output is a larger effect than color center formation for scintillator thickness $\leq1$ cm. For the blue scintillator (EJ-200), the transmission measurements indicate damage to the fluors. We also find that while PVT is more resistant to radiation damage than PS at dose rates higher than about 100 Gy/hr for EJ-200 fluors, they show similar damage at lower dose rates and for EJ-260 fluors.

physics.ins-det

The Future Circular Collider: a Summary for the US 2021 Snowmass Process

In this white paper for the 2021 Snowmass process, we give a description of the proposed Future Circular Collider (FCC) project and its physics program. The paper summarizes and updates the discussion submitted to the European Strategy on Particle Physics. After construction of an approximately 90 km tunnel, an electron-positron collider based on established technologies allows world-record instantaneous luminosities at center-of-mass energies from the Z resonance up to tt thresholds, enabling a rich set of fundamental measurements including Higgs couplings determinations at the sub percent level, precision tests of the weak and strong forces, and searches for new particles, including dark matter, both directly and via virtual corrections or mixing. Among other possibilities, the FCC-ee will be able to (i) indirectly discover new particles coupling to the Higgs and/or electroweak bosons up to scales around 7 and 50 TeV, respectively; (ii) perform competitive SUSY tests at the loop level in regions not accessible at the LHC; (iii) study heavy-flavor and tau physics in ultra-rare decays beyond the LHC reach, and (iv) achieve the best potential in direct collider searches for dark matter, sterile neutrinos, and axion-like particles with masses up to around 90 GeV. The tunnel can then be reused for a proton-proton collider, establishing record center-of-mass collision energy, allowing unprecedented reach for direct searches for new particles up to the around 50 TeV scale, and a diverse program of measurements of the Standard Model and Higgs boson, including a precision measurement of the Higgs self-coupling, and conclusively testing weakly-interacting massive particle scenarios of thermal relic dark matter.

hep-ex

Gravitons probing from stochastic gravitational waves background

Quantum gravity is a challenge in physics, and the existence of graviton is the prime question at present. We study the detectability of the quantum noise induced by gravitons in this letter. The correlation of the quantum noise in the squeezed state is calculated, but we are surprised to find that the result is the same as those from Grishchuk et.al. and Parikh et.al. This implies that they are essentially about one thing: the quantum noise from the gravitons. The further discussion shows the quantum noise should be completed from the leading order of the interaction between gravitation and the detector. The squeezed factor is estimated, and with it, the spectrum of the quantum noise is found to be of the form $Ω_0 \sim ν^{4+a_0 β+b_0}$. After comparing it to the sensitivities of several gravitational wave detectors, we conclude that the quantum noise is detectable in the future.

gr-qc

New perspectives on segmented crystal calorimeters for future colliders

Crystal calorimeters have a long history of pushing the frontier on high-resolution electromagnetic (EM) calorimetry. We explore in this paper major innovations in collider detector performance that can be achieved with crystal calorimetry when longitudinal segmentation and dual-readout capabilities are combined with a new high EM resolution approach to PFA in multi-jet events, such as $e^+e^+\rightarrow HZ$ events in all-hadronic final-states at Higgs factories. We demonstrate a new technique for pre-processing $π^0$ momenta through combinatoric di-photon pairing in advance of applying jet algorithms. This procedure significantly reduces $π^0$ photon splitting across jets in multi-jet events. The correct photon-to-jet assignment efficiency improves by a factor of 3 with a $3\%/\sqrt{E}$ EM resolution. In addition, the technique of bremsstrahlung photon recovery significantly improves electron momentum measurements. A high EM resolution calorimeter increases the Z boson recoil mass resolution in Higgstrahlung events for decays into electron pairs to 80% of that for muon pairs. We present the design and optimization of a highly segmented crystal detector concept that achieves the required energy resolution, and a time resolution better than 30 ps providing exceptional particle identification capabilities. We demonstrate that, contrary to previous detector designs that suffered from large neutral hadron resolution degradation from one interaction length of crystals in front of a sampling hadron calorimeter, the implementation of dual-readout on crystals permits to achieve a resolution better than $30\%/\sqrt{E}\oplus 2\%$ for neutral hadrons. Our studies find that the integration of crystal calorimetry into future Higgs factory collider detectors can open new perspectives by yielding the highest level of combined EM and neutral hadron resolution in the PFA paradigm.

physics.ins-det

An Improved Evaluation of the Neutron Background in the PandaX-II Experiment

In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutron-induced high energy signals in the data. In addition, the probability of producing a dark-matter-like background per neutron is evaluated with a complete Monte Carlo generator, where the correlated emission of neutron(s) and $\gamma$(s) in the ($\alpha$, n) reactions and spontaneous fissions is taken into consideration. With this method, the neutron backgrounds in the Run 9 (26-ton-day) and Run 10 (28-ton-day) data sets of PandaX-II are estimated to be 0.66$\pm$0.24 and 0.47$\pm$0.25 events, respectively.

hep-ex

Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector

We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.

hep-ex