Searcharxiv⌕ Search

arXiv subjects

Yiming Xiao

Publications and source records attributed to Yiming Xiao.

At least 55 records · Page 3Linked to original sources

CT-based brain ventricle segmentation via diffusion Schrödinger Bridge without target domain ground truths

Efficient and accurate brain ventricle segmentation from clinical CT scans is critical for emergency surgeries like ventriculostomy. With the challenges in poor soft tissue contrast and a scarcity of well-annotated databases for clinical brain CTs, we introduce a novel uncertainty-aware ventricle segmentation technique without the need of CT segmentation ground truths by leveraging diffusion-model-based domain adaptation. Specifically, our method employs the diffusion Schrödinger Bridge and an attention recurrent residual U-Net to capitalize on unpaired CT and MRI scans to derive automatic CT segmentation from those of the MRIs, which are more accessible. Importantly, we propose an end-to-end, joint training framework of image translation and segmentation tasks, and demonstrate its benefit over training individual tasks separately. By comparing the proposed method against similar setups using two different GAN models for domain adaptation (CycleGAN and CUT), we also reveal the advantage of diffusion models towards improved segmentation and image translation quality. With a Dice score of 0.78$\pm$0.27, our proposed method outperformed the compared methods, including SynSeg-Net, while providing intuitive uncertainty measures to further facilitate quality control of the automatic segmentation outcomes. The implementation of our proposed method is available at: https://github.com/HealthX-Lab/DiffusionSynCTSeg.

eess.IV↗

MedCLIP-SAM: Bridging Text and Image Towards Universal Medical Image Segmentation

Medical image segmentation of anatomical structures and pathology is crucial in modern clinical diagnosis, disease study, and treatment planning. To date, great progress has been made in deep learning-based segmentation techniques, but most methods still lack data efficiency, generalizability, and interactability. Consequently, the development of new, precise segmentation methods that demand fewer labeled datasets is of utmost importance in medical image analysis. Recently, the emergence of foundation models, such as CLIP and Segment-Anything-Model (SAM), with comprehensive cross-domain representation opened the door for interactive and universal image segmentation. However, exploration of these models for data-efficient medical image segmentation is still limited, but is highly necessary. In this paper, we propose a novel framework, called MedCLIP-SAM that combines CLIP and SAM models to generate segmentation of clinical scans using text prompts in both zero-shot and weakly supervised settings. To achieve this, we employed a new Decoupled Hard Negative Noise Contrastive Estimation (DHN-NCE) loss to fine-tune the BiomedCLIP model and the recent gScoreCAM to generate prompts to obtain segmentation masks from SAM in a zero-shot setting. Additionally, we explored the use of zero-shot segmentation labels in a weakly supervised paradigm to improve the segmentation quality further. By extensively testing three diverse segmentation tasks and medical image modalities (breast tumor ultrasound, brain tumor MRI, and lung X-ray), our proposed framework has demonstrated excellent accuracy. Code is available at https://github.com/HealthX-Lab/MedCLIP-SAM.

cs.CV↗

Weakly supervised segmentation of intracranial aneurysms using a novel 3D focal modulation UNet

Accurate identification and quantification of unruptured intracranial aneurysms (UIAs) is crucial for the risk assessment and treatment of this cerebrovascular disorder. Current 2D manual assessment on 3D magnetic resonance angiography (MRA) is suboptimal and time-consuming. In addition, one major issue in medical image segmentation is the need for large well-annotated data, which can be expensive to obtain. Techniques that mitigate this requirement, such as weakly supervised learning with coarse labels are highly desirable. In the paper, we propose FocalSegNet, a novel 3D focal modulation UNet, to detect an aneurysm and offer an initial, coarse segmentation of it from time-of-flight MRA image patches, which is further refined with a dense conditional random field (CRF) post-processing layer to produce a final segmentation map. We trained and evaluated our model on a public dataset, and in terms of UIA detection, our model showed a low false-positive rate of 0.21 and a high sensitivity of 0.80. For voxel-wise aneurysm segmentation, we achieved a Dice score of 0.68 and a 95% Hausdorff distance of ~0.95 mm, demonstrating its strong performance. We evaluated our algorithms against the state-of-the-art 3D Residual-UNet and Swin-UNETR, and illustrated the superior performance of our proposed FocalSegNet, highlighting the advantages of employing focal modulation for this task.

eess.IV↗

Architecture Analysis and Benchmarking of 3D U-shaped Deep Learning Models for Thoracic Anatomical Segmentation

Recent rising interests in patient-specific thoracic surgical planning and simulation require efficient and robust creation of digital anatomical models from automatic medical image segmentation algorithms. Deep learning (DL) is now state-of-the-art in various radiological tasks, and U-shaped DL models have particularly excelled in medical image segmentation since the inception of the 2D UNet. To date, many variants of U-shaped models have been proposed by the integration of different attention mechanisms and network configurations. Systematic benchmark studies which analyze the architecture of these models by leveraging the recent development of the multi-label databases, can provide valuable insights for clinical deployment and future model designs, but such studies are still rare. We conduct the first systematic benchmark study for variants of 3D U-shaped models (3DUNet, STUNet, AttentionUNet, SwinUNETR, FocalSegNet, and a novel 3D SwinUnet with four variants) with a focus on CT-based anatomical segmentation for thoracic surgery. Our study systematically examines the impact of different attention mechanisms, the number of resolution stages, and network configurations on segmentation accuracy and computational complexity. To allow cross-reference with other recent benchmarking studies, we also included a performance assessment of the BTCV abdominal structural segmentation. With the STUNet ranking at the top, our study demonstrated the value of CNN-based U-shaped models for the investigated tasks and the benefit of residual blocks in network configuration designs to boost segmentation performance.

eess.IV↗

Is visual explanation with Grad-CAM more reliable for deeper neural networks? a case study with automatic pneumothorax diagnosis

While deep learning techniques have provided the state-of-the-art performance in various clinical tasks, explainability regarding their decision-making process can greatly enhance the credence of these methods for safer and quicker clinical adoption. With high flexibility, Gradient-weighted Class Activation Mapping (Grad-CAM) has been widely adopted to offer intuitive visual interpretation of various deep learning models' reasoning processes in computer-assisted diagnosis. However, despite the popularity of the technique, there is still a lack of systematic study on Grad-CAM's performance on different deep learning architectures. In this study, we investigate its robustness and effectiveness across different popular deep learning models, with a focus on the impact of the networks' depths and architecture types, by using a case study of automatic pneumothorax diagnosis in X-ray scans. Our results show that deeper neural networks do not necessarily contribute to a strong improvement of pneumothorax diagnosis accuracy, and the effectiveness of GradCAM also varies among different network architectures.

eess.IV↗

Weakly Supervised Intracranial Hemorrhage Segmentation using Head-Wise Gradient-Infused Self-Attention Maps from a Swin Transformer in Categorical Learning

Intracranial hemorrhage (ICH) is a life-threatening medical emergency that requires timely and accurate diagnosis for effective treatment and improved patient survival rates. While deep learning techniques have emerged as the leading approach for medical image analysis and processing, the most commonly employed supervised learning often requires large, high-quality annotated datasets that can be costly to obtain, particularly for pixel/voxel-wise image segmentation. To address this challenge and facilitate ICH treatment decisions, we introduce a novel weakly supervised method for ICH segmentation, utilizing a Swin transformer trained on an ICH classification task with categorical labels. Our approach leverages a hierarchical combination of head-wise gradient-infused self-attention maps to generate accurate image segmentation. Additionally, we conducted an exploratory study on different learning strategies and showed that binary ICH classification has a more positive impact on self-attention maps compared to full ICH subtyping. With a mean Dice score of 0.44, our technique achieved similar ICH segmentation performance as the popular U-Net and Swin-UNETR models with full supervision and outperformed a similar weakly supervised approach using GradCAM, demonstrating the excellent potential of the proposed framework in challenging medical image segmentation tasks. Our code is available at https://github.com/HealthX-Lab/HGI-SAM.

cs.CV↗

VesselShot: Few-shot learning for cerebral blood vessel segmentation

Angiography is widely used to detect, diagnose, and treat cerebrovascular diseases. While numerous techniques have been proposed to segment the vascular network from different imaging modalities, deep learning (DL) has emerged as a promising approach. However, existing DL methods often depend on proprietary datasets and extensive manual annotation. Moreover, the availability of pre-trained networks specifically for medical domains and 3D volumes is limited. To overcome these challenges, we propose a few-shot learning approach called VesselShot for cerebrovascular segmentation. VesselShot leverages knowledge from a few annotated support images and mitigates the scarcity of labeled data and the need for extensive annotation in cerebral blood vessel segmentation. We evaluated the performance of VesselShot using the publicly available TubeTK dataset for the segmentation task, achieving a mean Dice coefficient (DC) of 0.62(0.03).

eess.IV↗

Dense Error Map Estimation for MRI-Ultrasound Registration in Brain Tumor Surgery Using Swin UNETR

Early surgical treatment of brain tumors is crucial in reducing patient mortality rates. However, brain tissue deformation (called brain shift) occurs during the surgery, rendering pre-operative images invalid. As a cost-effective and portable tool, intra-operative ultrasound (iUS) can track brain shift, and accurate MRI-iUS registration techniques can update pre-surgical plans and facilitate the interpretation of iUS. This can boost surgical safety and outcomes by maximizing tumor removal while avoiding eloquent regions. However, manual assessment of MRI-iUS registration results in real-time is difficult and prone to errors due to the 3D nature of the data. Automatic algorithms that can quantify the quality of inter-modal medical image registration outcomes can be highly beneficial. Therefore, we propose a novel deep-learning (DL) based framework with the Swin UNETR to automatically assess 3D-patch-wise dense error maps for MRI-iUS registration in iUS-guided brain tumor resection and show its performance with real clinical data for the first time.

eess.IV↗

How inter-rater variability relates to aleatoric and epistemic uncertainty: a case study with deep learning-based paraspinal muscle segmentation

Recent developments in deep learning (DL) techniques have led to great performance improvement in medical image segmentation tasks, especially with the latest Transformer model and its variants. While labels from fusing multi-rater manual segmentations are often employed as ideal ground truths in DL model training, inter-rater variability due to factors such as training bias, image noise, and extreme anatomical variability can still affect the performance and uncertainty of the resulting algorithms. Knowledge regarding how inter-rater variability affects the reliability of the resulting DL algorithms, a key element in clinical deployment, can help inform better training data construction and DL models, but has not been explored extensively. In this paper, we measure aleatoric and epistemic uncertainties using test-time augmentation (TTA), test-time dropout (TTD), and deep ensemble to explore their relationship with inter-rater variability. Furthermore, we compare UNet and TransUNet to study the impacts of Transformers on model uncertainty with two label fusion strategies. We conduct a case study using multi-class paraspinal muscle segmentation from T2w MRIs. Our study reveals the interplay between inter-rater variability and uncertainties, affected by choices of label fusion strategies and DL models.

eess.IV↗

FocalErrorNet: Uncertainty-aware focal modulation network for inter-modal registration error estimation in ultrasound-guided neurosurgery

In brain tumor resection, accurate removal of cancerous tissues while preserving eloquent regions is crucial to the safety and outcomes of the treatment. However, intra-operative tissue deformation (called brain shift) can move the surgical target and render the pre-surgical plan invalid. Intra-operative ultrasound (iUS) has been adopted to provide real-time images to track brain shift, and inter-modal (i.e., MRI-iUS) registration is often required to update the pre-surgical plan. Quality control for the registration results during surgery is important to avoid adverse outcomes, but manual verification faces great challenges due to difficult 3D visualization and the low contrast of iUS. Automatic algorithms are urgently needed to address this issue, but the problem was rarely attempted. Therefore, we propose a novel deep learning technique based on 3D focal modulation in conjunction with uncertainty estimation to accurately assess MRI-iUS registration errors for brain tumor surgery. Developed and validated with the public RESECT clinical database, the resulting algorithm can achieve an estimation error of 0.59+-0.57 mm.

eess.IV↗

Towards multi-modal anatomical landmark detection for ultrasound-guided brain tumor resection with contrastive learning

Homologous anatomical landmarks between medical scans are instrumental in quantitative assessment of image registration quality in various clinical applications, such as MRI-ultrasound registration for tissue shift correction in ultrasound-guided brain tumor resection. While manually identified landmark pairs between MRI and ultrasound (US) have greatly facilitated the validation of different registration algorithms for the task, the procedure requires significant expertise, labor, and time, and can be prone to inter- and intra-rater inconsistency. So far, many traditional and machine learning approaches have been presented for anatomical landmark detection, but they primarily focus on mono-modal applications. Unfortunately, despite the clinical needs, inter-modal/contrast landmark detection has very rarely been attempted. Therefore, we propose a novel contrastive learning framework to detect corresponding landmarks between MRI and intra-operative US scans in neurosurgery. Specifically, two convolutional neural networks were trained jointly to encode image features in MRI and US scans to help match the US image patch that contain the corresponding landmarks in the MRI. We developed and validated the technique using the public RESECT database. With a mean landmark detection accuracy of 5.88+-4.79 mm against 18.78+-4.77 mm with SIFT features, the proposed method offers promising results for MRI-US landmark detection in neurosurgical applications for the first time.

cs.CV↗

SONIA: an immersive customizable virtual reality system for the education and exploration of brain networks

While mastery of neuroanatomy is important for the investigation of the brain, there is an increasing interest in exploring the neural pathways to better understand the roles of neural circuitry in brain functions. To tackle the limitations of traditional 2D-display-based neuronavigation software in intuitively visualizing complex 3D anatomies, several virtual reality (VR) and augmented reality (AR) solutions have been proposed to facilitate neuroanatomical education. However, with the increasing knowledge on brain connectivity and the functioning of the sub-systems, there is still a lack of similar software solutions for the education and exploration of these topics, which demand more elaborate visualization and interaction strategies. To address this gap, we designed the immerSive custOmizable Neuro learnIng plAform (SONIA), a novel user-friendly VR software system with a multi-scale interaction paradigm that allows flexible customization of learning materials. With both quantitative and qualitative evaluations through user studies, the proposed system is shown to have high usability, attractive visual design, and good educational value. As the first immersive system that integrates customizable design and detailed narratives of the brain sub-systems for the education of neuroanatomy and brain connectivity, SONIA showcases new potential directions and provides valuable insights regarding medical learning and exploration in VR.

cs.HC↗

Assessment of user-interaction strategies for neurosurgical data navigation and annotation in virtual reality

While virtual-reality (VR) has shown great promise in radiological tasks, effective user-interaction strategies that can improve efficiency and ergonomics are still under-explored and systematic evaluations of VR interaction techniques in the context of complex anatomical models are rare. Therefore, our study aims to identify the most effective interaction techniques for two common neurosurgical planning tasks in VR (point annotation and note-taking) from the state-of-the-arts, and propose a novel technique for efficient sub-volume selection necessary in neuroanatomical navigation. We assessed seven user-interaction methods with multiple input modalities (gaze, head motion, controller, and voice) for point placement and note-taking in the context of annotating brain aneurysms for cerebrovascular surgery. Furthermore, we proposed and evaluated a novel technique, called magnified selection diorama (Maserama) for easy navigation and selection of complex 3D anatomies in VR. Both quantitative and semi-quantitative (i.e., NASA Task Load Index) metrics were employed through user studies to reveal the performance of each interaction scheme in terms of accuracy, efficiency, and usability. Our evaluations demonstrated that controller-based interaction is preferred over eye-tracking-based methods for point placement while voice recording and virtual keyboard typing are better than freehand writing for note-taking. Furthermore, our new Maserama sub-volume selection technique was proven to be highly efficient and easy-to-use. Our study is the first to provide a systematic assessment of existing and new VR interaction schemes for neurosurgical data navigation and annotation. It offers valuable insights and tools to guide the design of future VR systems for radiological and surgical applications.

cs.HC↗

Fluorescent property of carbon dots extracted from cigarette smoke and the application in bio-imaging

Cigarette smoke is one of the six major pollution sources in the room air. It contains large number of particles with size less than 10 nm. There exist carbon dots (CDs) in cigarette smoke which have strong fluorescence and with good bio-compatibility and low toxicity. CDs in cigarette smoke can be applied in bio-imaging which has great potential applications in the integration of cancer diagnosis and treatment. In this paper, CDs were extracted from cigarette smoke. Then, sodium borohydride was added to CDs aqueous solution for reduction and the reduced CDs (R-CDs) were used for biological cell imaging. The results indicate that the CDs with the particle size $<$10 nm in cigarette smoke are self-assembled by the polymerizated polycyclic aromatic hydrocarbons (PAHs) and ammonium nitrite which are disk nano-structure composed of $sp^2$/$sp^3$ carbon and oxygen/nitrogen groups or polymers. Sodium borohydride can reduce the carbonyl group on the surface of CDs to hydroxyl group and increase the ratio of the Na 1s ratio of the CDs from 1.86 to 7.42. The CDs can emit blue fluorescence under ultraviolet irradiation. After reduction, the R-CDS have the intensity of fluorescence 7.2 times than before and the fluorescence quantum yield increase from 6.13\% to 8.86\%. The photoluminescence (PL) wavelength of R-CDS have red-shift of 7 nm which was due to the increasing of Na element ratio. The onion epidermal cells labeled with R-CDs show that the CDs could pass through the cell wall into the cell and reach the nucleus. The cell wall and the nucleus could be clearly visualized. CDs also shows low toxicity to human bronchial epithelial cells (BEAS-2B) with good biological activity. The obtained results indicate that the CDs and R-CDs have good fluorescent property which could be used as bio-imaging agent.

physics.bio-ph↗

Learn2Reg: comprehensive multi-task medical image registration challenge, dataset and evaluation in the era of deep learning

Image registration is a fundamental medical image analysis task, and a wide variety of approaches have been proposed. However, only a few studies have comprehensively compared medical image registration approaches on a wide range of clinically relevant tasks. This limits the development of registration methods, the adoption of research advances into practice, and a fair benchmark across competing approaches. The Learn2Reg challenge addresses these limitations by providing a multi-task medical image registration data set for comprehensive characterisation of deformable registration algorithms. A continuous evaluation will be possible at https://learn2reg.grand-challenge.org. Learn2Reg covers a wide range of anatomies (brain, abdomen, and thorax), modalities (ultrasound, CT, MR), availability of annotations, as well as intra- and inter-patient registration evaluation. We established an easily accessible framework for training and validation of 3D registration methods, which enabled the compilation of results of over 65 individual method submissions from more than 20 unique teams. We used a complementary set of metrics, including robustness, accuracy, plausibility, and runtime, enabling unique insight into the current state-of-the-art of medical image registration. This paper describes datasets, tasks, evaluation methods and results of the challenge, as well as results of further analysis of transferability to new datasets, the importance of label supervision, and resulting bias. While no single approach worked best across all tasks, many methodological aspects could be identified that push the performance of medical image registration to new state-of-the-art performance. Furthermore, we demystified the common belief that conventional registration methods have to be much slower than deep-learning-based methods.

eess.IV↗

DiffeoRaptor: Diffeomorphic Inter-modal Image Registration using RaPTOR

Purpose: Diffeomorphic image registration is essential in many medical imaging applications. Several registration algorithms of such type have been proposed, but primarily for intra-contrast alignment. Currently, efficient inter-modal/contrast diffeomorphic registration, which is vital in numerous applications, remains a challenging task. Methods: We proposed a novel inter-modal/contrast registration algorithm that leverages Robust PaTch-based cOrrelation Ratio (RaPTOR) metric to allow inter-modal/contrast image alignment and bandlimited geodesic shooting demonstrated in Fourier Approximated Lie Algebras (FLASH) algorithm for fast diffeomorphic registration. Results: The proposed algorithm, named DiffeoRaptor, was validated with three public databases for the tasks of brain and abdominal image registration while comparing the results against three state-of-the-art techniques, including FLASH, NiftyReg, and Symmetric image normalization (SyN). Conclusions: Our results demonstrated that DiffeoRaptor offered comparable or better registration performance in terms of registration accuracy. Moreover, DiffeoRaptor produces smoother deformations than SyN in inter-modal and contrast registration. The code for DiffeoRaptor is publicly available at https://github.com/nimamasoumi/DiffeoRaptor.

eess.IV↗

RESECT-SEG: Open access annotations of intra-operative brain tumor ultrasound images

Purpose: Registration and segmentation of magnetic resonance (MR) and ultrasound (US) images play an essential role in surgical planning and resection of brain tumors. However, validating these techniques is challenging due to the scarcity of publicly accessible sources with high-quality ground truth information. To this end, we propose a unique annotation dataset of tumor tissues and resection cavities from the previously published RESECT dataset (Xiao et al. 2017) to encourage a more rigorous assessments of image processing techniques. Acquisition and validation methods: The RESECT database consists of MR and intraoperative US (iUS) images of 23 patients who underwent resection surgeries. The proposed dataset contains tumor tissues and resection cavity annotations of the iUS images. The quality of annotations were validated by two highly experienced neurosurgeons through several assessment criteria. Data format and availability: Annotations of tumor tissues and resection cavities are provided in 3D NIFTI formats. Both sets of annotations are accessible online in the \url{https://osf.io/6y4db}. Discussion and potential applications: The proposed database includes tumor tissue and resection cavity annotations from real-world clinical ultrasound brain images to evaluate segmentation and registration methods. These labels could also be used to train deep learning approaches. Eventually, this dataset should further improve the quality of image guidance in neurosurgery.

physics.med-ph↗

ConferencingSpeech 2022 Challenge: Non-intrusive Objective Speech Quality Assessment (NISQA) Challenge for Online Conferencing Applications

With the advances in speech communication systems such as online conferencing applications, we can seamlessly work with people regardless of where they are. However, during online meetings, speech quality can be significantly affected by background noise, reverberation, packet loss, network jitter, etc. Because of its nature, speech quality is traditionally assessed in subjective tests in laboratories and lately also in crowdsourcing following the international standards from ITU-T Rec. P.800 series. However, those approaches are costly and cannot be applied to customer data. Therefore, an effective objective assessment approach is needed to evaluate or monitor the speech quality of the ongoing conversation. The ConferencingSpeech 2022 challenge targets the non-intrusive deep neural network models for the speech quality assessment task. We open-sourced a training corpus with more than 86K speech clips in different languages, with a wide range of synthesized and live degradations and their corresponding subjective quality scores through crowdsourcing. 18 teams submitted their models for evaluation in this challenge. The blind test sets included about 4300 clips from wide ranges of degradations. This paper describes the challenge, the datasets, and the evaluation methods and reports the final results.

cs.SD↗