Searcharxiv⌕ Search

arXiv subjects

Yinan Wang

Publications and source records attributed to Yinan Wang.

At least 37 records · Page 2Linked to original sources

An 11.7-GHz ScAlN FBAR Filter: Case Study on Scaling Limits and Challenges

This paper reports an 11.7 GHz compact 50 ohm ladder filter based on single layer Scandium Aluminum Nitride (ScAlN) film bulk acoustic resonators (FBARs) with platinum (Pt) electrodes, and uses it as a quantitative case study of the limits encountered when directly scaling to higher frequencies. The measured filter achieves a 3 dB fractional bandwidth (FBW) of 4.0% and an out of band rejection greater than 23.1 dB, with a minimum insertion loss (IL) of 6.8 dB. We analyze the origin of this performance through a quantitative framework: (1) a loss decomposition study, (2) frequency shift sensitivity that explains the discrepancy between simulated and measured center frequency, (3) FBW sensitivity to series shunt separation and port impedance, and (4) stress limited aperture that constrains device size. The results establish a realistic, fabricable baseline for directly scaled single layer ScAlN FBAR filters and outline materials, electrode, and stress management directions toward lower loss mmWave acoustic filters.

physics.app-ph↗

Order Estimation of Linear-Phase FIR Filters for DAC Equalization in Multiple Nyquist Bands

This letter considers the design of linear-phase finite-length impulse response (FIR) filters for equalization of the frequency responses of digital-to-analog converters (DACs). The letter derives estimates for the filter orders required, as functions of the bandwidth and equalization accuracy, for four DAC pulses that are used in DACs in multiple Nyquist bands. The estimates are derived through a large set of minimax-optimal equalizers and the use of symbolic regression followed by minimax-optimal curve fitting for further enhancement. Design examples included demonstrate the accuracy of the proposed estimates. In addition, the letter discusses the appropriateness of the four types of linear-phase FIR filters, for the different equalizer cases, as well as the corresponding properties of the equalized systems.

eess.SP↗

OpenCSP: A Deep Learning Framework for Crystal Structure Prediction from Ambient to High Pressure

High-pressure crystal structure prediction (CSP) underpins advances in condensed matter physics, planetary science, and materials discovery. Yet, most large atomistic models are trained on near-ambient, equilibrium data, leading to degraded stress accuracy at tens to hundreds of gigapascals and sparse coverage of pressure-stabilized stoichiometries and dense coordination motifs. Here, we introduce OpenCSP, a machine learning framework for CSP tasks spanning ambient to high-pressure conditions. This framework comprises an open-source pressure-resolved dataset alongside a suite of publicly available atomistic models that are jointly optimized for accuracy in energy, force, and stress predictions. The dataset is constructed via randomized high-pressure sampling and iteratively refined through an uncertainty-guided concurrent learning strategy, which enriches underrepresented compression regimes while suppressing redundant DFT labeling. Despite employing a training corpus one to two orders of magnitude smaller than those of leading large models, OpenCSP achieves comparable or superior performance in high-pressure enthalpy ranking and stability prediction. Across benchmark CSP tasks spanning a wide pressure window, our models match or surpass MACE-MPA-0, MatterSim v1 5M, and GRACE-2L-OAM, with the largest gains observed at elevated pressures. These results demonstrate that targeted, pressure-aware data acquisition coupled with scalable architectures enables data-efficient, high-fidelity CSP, paving the way for autonomous materials discovery under ambient and extreme conditions.

cond-mat.mtrl-sci↗

LAMBench: A Benchmark for Large Atomistic Models

Large Atomistic Models (LAMs) have undergone remarkable progress recently, emerging as universal or fundamental representations of the potential energy surface defined by the first-principles calculations of atomistic systems. However, our understanding of the extent to which these models achieve true universality, as well as their comparative performance across different models, remains limited. This gap is largely due to the lack of comprehensive benchmarks capable of evaluating the effectiveness of LAMs as approximations to the universal potential energy surface. In this study, we introduce LAMBench, a benchmarking system designed to evaluate LAMs in terms of their generalizability, adaptability, and applicability. These attributes are crucial for deploying LAMs as ready-to-use tools across a diverse array of scientific discovery contexts. We benchmark ten state-of-the-art LAMs released prior to August 1, 2025, using LAMBench. Our findings reveal a significant gap between the current LAMs and the ideal universal potential energy surface. They also highlight the need for incorporating cross-domain training data, supporting multi-fidelity modeling, and ensuring the models' conservativeness and differentiability. As a dynamic and extensible platform, LAMBench is intended to continuously evolve, thereby facilitating the development of robust and generalizable LAMs capable of significantly advancing scientific research. The LAMBench code is open-sourced at https://github.com/deepmodeling/lambench, and an interactive leaderboard is available at https://www.aissquare.com/openlam?tab=Benchmark.

physics.comp-ph↗

Thin-film scandium aluminum nitride bulk acoustic resonator with high Q of 208 and K2 of 9.5% at 12.5 GHz

This work describes sputtered scandium aluminum nitride (ScAlN) thin-film bulk acoustic resonators (FBAR) at 12.5 GHz with high electromechanical coupling (k2) of 9.5% and quality factor (Q) of 208, resulting in a figure of merit (FoM, Qk2) of 19.8. ScAlN resonators employ a stack of 90 nm thick 20% Sc doping ScAlN piezoelectric film on the floating bottom 38 nm thick platinum (Pt) electrode to achieve low losses and high coupling toward centimeter wave (cmWave) frequency band operation. Three fabricated and FBARs are reported, show promising prospects of ScAlN-Pt stack towards cmWave front-end filters.

physics.app-ph↗

Thermal Resilience of Suspended Thin-Film Lithium Niobate Acoustic Resonators up to 550 °C

This paper reports a suspended thin-film lithium niobate (LN) piezoelectric resonator platform surviving high annealing temperatures of 550 °C, among the highest temperature at which the thermal resilience of suspended LN resonators is studied. Acoustic resonators are built on 600 nm thick transferred stoichiometric LN on silicon wafers with 40 nm thick platinum (Pt) electrodes, selected for high temperature operation. The fabricated resonators are first annealed at 250 °C, and the anneal temperature is incrementally increased to 550 °C after 7 rounds of annealing. The annealing is shown to upshift resonant frequencies and can increase the quality factor (Q), within a temperature range, before it gradually damages the device performance. This work presents promising results for using the suspended thin-film LN platform for resonators, sensors, and transducers in harsh thermal environments.

physics.app-ph↗

A Comparative Dosimetric Study of Proton and Photon Therapy in Stereotactic Arrhythmia Radioablation for Ventricular Tachycardia

Purpose: VT is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. STAR has emerged as a non-invasive option for such patients. While photon-based STAR has shown efficacy, proton therapy offers potential advantages due to its superior dose conformity and sparing of critical OARs, including the heart itself. This study aims to investigate and compare the dosimetry between proton and photon therapy for VT, focusing on target coverage and OAR sparing. Methods: We performed a retrospective study on a cohort of 34 VT patients who received photon STAR. Proton STAR plans were generated using robust optimization in RayStation to deliver the same prescription dose of 25 Gy in a single fraction while minimizing dose to OARs. Dosimetric metrics, including D99, D95, Dmean, and D0.03cc, were extracted for critical OARs and VAS. Shapiro-Wilk tests were used to assess normality, followed by paired t-tests or Wilcoxon signed-rank tests for statistical comparisons between modalities, with Bonferroni correction applied for multiple comparisons. Results: Proton and photon plans achieved comparable target coverage, with VAS D95 of 24.1 +/- 1.2 Gy vs. 24.7 +/- 1.0 Gy (p=0.294). Proton therapy significantly reduced OAR doses, including heart Dmean (3.6 +/- 1.5 Gy vs. 5.5 +/- 2.0 Gy, p<0.001), lungs Dmean (1.6 +/- 1.5 Gy vs. 2.1 +/- 1.4 Gy, p<0.001), and esophagus Dmean (0.3 +/- 0.6 Gy vs. 1.6 +/- 1.3 Gy, p<0.001), while maintaining optimal target coverage. Conclusion: Proton therapy for STAR demonstrates significant dosimetric advantages in sparing the heart and other critical OARs compared to photon therapy for VT, while maintaining equivalent target coverage. These findings highlight the potential of proton therapy to reduce treatment-related toxicity and improve outcomes for VT patients.

physics.med-ph↗

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Active breath-hold techniques effectively mitigate respiratory motion but pose challenges for patients who are ineligible for the procedure. Conventional treatment planning relies on multiple energy layers, extending delivery time due to slow layer switching. We propose to use pin ridge filters (pRFs), initially developed for FLASH radiotherapy, to construct a single energy beam plan and minimize dose delivery time. The conventional ITV--based free--breathing treatment plan served as the reference. A GTV--based IMPT--DS plan with a downstream energy modulation strategy was developed based on a new beam model that was commissioned using the maximum energy of the IMPT plan. Consequently, a nested iterative pencil beam direction (PBD) spot reduction process removed low--weighted spots along each PBD, generating pRFs with coarser resolution. Finally, the IMPT--DS plan was then converted into an IMPT--pRF plan, using a monoenergetic beam with optimized spot positions and weights. This approach was validated on lung and liver SBRT cases (10 Gy RBE x 5). For the lung case, the mean lung--GTV dose decreased from 10.3 Gy to 6.9 Gy, with delivery time reduced from 188.79 to 36.16 seconds. The largest time reduction was at 150°, from 47.4 to 3.99 seconds. For the liver case, the mean liver--GTV dose decreased from 5.7 Gy to 3.8 Gy, with delivery time reduced from 111.13 to 30.54 seconds. The largest time reduction was at 180°, from 38.57 to 3.94 seconds. This method significantly reduces dose delivery time and organ at risk dose. Further analysis is needed to validate its clinical feasibility.

physics.med-ph↗

Uni-3DAD: GAN-Inversion Aided Universal 3D Anomaly Detection on Model-free Products

Anomaly detection is a long-standing challenge in manufacturing systems. Traditionally, anomaly detection has relied on human inspectors. However, 3D point clouds have gained attention due to their robustness to environmental factors and their ability to represent geometric data. Existing 3D anomaly detection methods generally fall into two categories. One compares scanned 3D point clouds with design files, assuming these files are always available. However, such assumptions are often violated in many real-world applications where model-free products exist, such as fresh produce (i.e., ``Cookie", ``Potato", etc.), dentures, bone, etc. The other category compares patches of scanned 3D point clouds with a library of normal patches named memory bank. However, those methods usually fail to detect incomplete shapes, which is a fairly common defect type (i.e., missing pieces of different products). The main challenge is that missing areas in 3D point clouds represent the absence of scanned points. This makes it infeasible to compare the missing region with existing point cloud patches in the memory bank. To address these two challenges, we proposed a unified, unsupervised 3D anomaly detection framework capable of identifying all types of defects on model-free products. Our method integrates two detection modules: a feature-based detection module and a reconstruction-based detection module. Feature-based detection covers geometric defects, such as dents, holes, and cracks, while the reconstruction-based method detects missing regions. Additionally, we employ a One-class Support Vector Machine (OCSVM) to fuse the detection results from both modules. The results demonstrate that (1) our proposed method outperforms the state-of-the-art methods in identifying incomplete shapes and (2) it still maintains comparable performance with the SOTA methods in detecting all other types of anomalies.

cs.CV↗

H2G2-Net: A Hierarchical Heterogeneous Graph Generative Network Framework for Discovery of Multi-Modal Physiological Responses

Discovering human cognitive and emotional states using multi-modal physiological signals draws attention across various research applications. Physiological responses of the human body are influenced by human cognition and commonly used to analyze cognitive states. From a network science perspective, the interactions of these heterogeneous physiological modalities in a graph structure may provide insightful information to support prediction of cognitive states. However, there is no clue to derive exact connectivity between heterogeneous modalities and there exists a hierarchical structure of sub-modalities. Existing graph neural networks are designed to learn on non-hierarchical homogeneous graphs with pre-defined graph structures; they failed to learn from hierarchical, multi-modal physiological data without a pre-defined graph structure. To this end, we propose a hierarchical heterogeneous graph generative network (H2G2-Net) that automatically learns a graph structure without domain knowledge, as well as a powerful representation on the hierarchical heterogeneous graph in an end-to-end fashion. We validate the proposed method on the CogPilot dataset that consists of multi-modal physiological signals. Extensive experiments demonstrate that our proposed method outperforms the state-of-the-art GNNs by 5%-20% in prediction accuracy.

cs.LG↗

Using Modularized Pin Ridge Filter in Proton FLASH Planning for Liver Stereotactic Ablative Body Radiotherapy

We previously developed a FLASH planning framework for streamlined pin-ridge-filter (pin-RF) design, demonstrating its feasibility for single-energy proton FLASH planning. In this study, we refined the pin-RF design for easy assembly using reusable modules, focusing on its application in liver SABR. This framework generates an intermediate IMPT plan and translates it into step widths and thicknesses of pin-RFs for a single-energy FLASH plan. Parameters like energy spacing, monitor unit limit, and spot quantity were adjusted during IMPT planning, resulting in pin-RFs assembled using predefined modules with widths from 1 to 6 mm, each with a WET of 5 mm. This approach was validated on three liver SABR cases. FLASH doses, quantified using the FLASH effectiveness model at 1 to 5 Gy thresholds, were compared to conventional IMPT (IMPT-CONV) doses to assess clinical benefits. The highest demand for 6 mm width modules, moderate for 2-4 mm, and minimal for 1- and 5-mm modules were shown across all cases. At lower dose thresholds, the two-beam case showed significant dose reductions (>23%), while the other two three-beam cases showed moderate reductions (up to 14.7%), indicating the need for higher fractional beam doses for an enhanced FLASH effect. Positive clinical benefits were seen only in the two-beam case at the 5 Gy threshold. At the 1 Gy threshold, the FLASH plan of the two-beam case outperformed its IMPT-CONV plan, reducing dose indicators by up to 28.3%. However, the three-beam cases showed negative clinical benefits at the 1 Gy threshold, with some dose indicators increasing by up to 16% due to lower fractional beam doses and closer beam arrangements. This study evaluated the feasibility of modularizing streamlined pin-RFs in single-energy proton FLASH planning for liver SABR, offering guidance on optimal module composition and strategies to enhance FLASH planning.

physics.med-ph↗

An Intelligent End-to-End Neural Architecture Search Framework for Electricity Forecasting Model Development

Recent years have witnessed exponential growth in developing deep learning (DL) models for time-series electricity forecasting in power systems. However, most of the proposed models are designed based on the designers' inherent knowledge and experience without elaborating on the suitability of the proposed neural architectures. Moreover, these models cannot be self-adjusted to dynamically changed data patterns due to the inflexible design of their structures. Although several recent studies have considered the application of the neural architecture search (NAS) technique for obtaining a network with an optimized structure in the electricity forecasting sector, their training process is computationally expensive and their search strategies are not flexible, indicating that the NAS application in this area is still at an infancy stage. In this study, we propose an intelligent automated architecture search (IAAS) framework for the development of time-series electricity forecasting models. The proposed framework contains three primary components, i.e., network function-preserving transformation operation, reinforcement learning (RL)-based network transformation control, and heuristic network screening, which aim to improve the search quality of a network structure. After conducting comprehensive experiments on two publicly-available electricity load datasets and two wind power datasets, we demonstrate that the proposed IAAS framework significantly outperforms the ten existing models or methods in terms of forecasting accuracy and stability. Finally, we perform an ablation experiment to showcase the importance of critical components in the proposed IAAS framework in improving forecasting accuracy.

cs.LG↗

Spatiotemporal Predictions of Toxic Urban Plumes Using Deep Learning

Industrial accidents, chemical spills, and structural fires can release large amounts of harmful materials that disperse into urban atmospheres and impact populated areas. Computer models are typically used to predict the transport of toxic plumes by solving fluid dynamical equations. However, these models can be computationally expensive due to the need for many grid cells to simulate turbulent flow and resolve individual buildings and streets. In emergency response situations, alternative methods are needed that can run quickly and adequately capture important spatiotemporal features. Here, we present a novel deep learning model called ST-GasNet that was inspired by the mathematical equations that govern the behavior of plumes as they disperse through the atmosphere. ST-GasNet learns the spatiotemporal dependencies from a limited set of temporal sequences of ground-level toxic urban plumes generated by a high-resolution large eddy simulation model. On independent sequences, ST-GasNet accurately predicts the late-time spatiotemporal evolution, given the early-time behavior as an input, even for cases when a building splits a large plume into smaller plumes. By incorporating large-scale wind boundary condition information, ST-GasNet achieves a prediction accuracy of at least 90% on test data for the entire prediction period.

cs.LG↗

Adaptive Proton Therapy Using CBCT-Guided Digital Twins

This study aims to develop a digital twin (DT) framework to enhance adaptive proton stereotactic body radiation therapy (SBRT) for prostate cancer. Prostate SBRT has emerged as a leading option for external beam radiotherapy due to its effectiveness and reduced treatment duration. However, interfractional anatomy variations can impact treatment outcomes. This study seeks to address these uncertainties using DT concept, with the goal of improving treatment quality, potentially revolutionizing prostate radiotherapy to offer personalized treatment solutions. Our study presented a pioneering approach that leverages DT technology to enhance adaptive proton SBRT. The framework improves treatment plans by utilizing patient-specific CTV setup uncertainty, which is usually smaller than conventional clinical setups. This research contributes to the ongoing efforts to enhance the efficiency and efficacy of prostate radiotherapy, with ultimate goals of improving patient outcomes and life quality.

physics.med-ph↗

ADs: Active Data-sharing for Data Quality Assurance in Advanced Manufacturing Systems

Machine learning (ML) methods are widely used in industrial applications, which usually require a large amount of training data. However, data collection needs extensive time costs and investments in the manufacturing system, and data scarcity commonly exists. Therefore, data-sharing is widely enabled among multiple machines with similar functionality to augment the dataset for building ML methods. However, distribution mismatch inevitably exists in their data due to different working conditions, while the ML methods are assumed to be built and tested on the dataset following the same distribution. Thus, an Active Data-sharing (ADs) framework is proposed to ensure the quality of the shared data among multiple machines. It is designed to simultaneously select the most informative data points benefiting the downstream tasks and mitigate the distribution mismatch among all selected data points. The proposed method is validated on anomaly detection on in-situ monitoring data from three additive manufacturing processes.

cs.LG↗

Streamlined Pin-Ridge-Filter Design for Single-energy Proton FLASH Planning

Purpose: This study explored the feasibility of a streamlined pin-shaped ridge filter (pin-RF) design for single-energy proton FLASH planning. Methods: An inverse planning framework integrated within a TPS was established for FLASH planning. The framework involves generating a IMPT plan based on downstream energy modulation strategy (IMPT-DS), followed by a nested spot reduction process to iteratively reduce the total number of pencil beam directions (PBDs) and energy layers along each PBD for the IMPT-DS plan. The IMPT-DS plan is then translated into the pin-RFs for a single-energy IMPT plan (IMPT-RF). The framework was validated on three lung cases, quantifying the FLASH dose of the IMPT-RF plan using the FLASH effectiveness model and comparing it with the reference dose of a conventional IMPT plan to assess the clinical benefit of the FLASH planning technique. Results: The IMPT-RF plans closely matched the corresponding IMPT-DS plans in high dose conformity, with minimal changes in V7Gy and V7.4Gy for the lung (< 5%) and small increases in Dmax for other OARs (< 3.2 Gy). Comparing the FLASH doses to the doses of corresponding IMPT-RF plans, drastic reductions of up to ~33% were observed in Dmax for OARs in the high-to-moderate-dose regions with negligible changes in Dmax for OARs in low-dose regions. Positive clinical benefits were observed with notable reductions of 18.4-33.0% in Dmax for OARs in the high-dose regions. However, in the moderate-to-low-dose regions, only marginal positive or even negative clinical benefit for OARs were observed, such as increased lung V7Gy and V7.4Gy (16.4-38.9%). Conclusions: A streamlined pin-RF design for single-energy proton FLASH planning was validated, revealing positive clinical benefits for OARs in the high dose regions. The coarsened design of the pin-RF demonstrates potential cost efficiency and efficient production.

physics.med-ph↗

A Retrospective Study on the Investigation of Potential Clinical Benefits of Online Adaptive Proton Therapy for Head and Neck Cancer

Online adaptive proton therapy (APT) is an ideal solution theoretically, which however is challenging to proton clinics. Although multiple groups have been endeavoring to develop online APT technology, there is a concern in the radiotherapy community about the necessity of online APT because of its unknown impact on treatment outcomes. Hence, we have performed a retrospective study to investigate the potential clinical effects of online APT for HN cancer patients in relative to the current offline APT via simulations. To mimic an online APT treatment course, we have recalculated and evaluated the actual dose of the current treatment plan on patient actual treatment anatomy captured by cone beam CT for each fraction. The cumulative dose of simulated online APT courses was compared to actual offline APT courses and the initially designed treatment plan dose. For patients 1 and 2, the simulated online ART course maintained a relatively higher CTV dose coverages than the offline ART course, particularly for CTV-Low, which led to an improvement of 2.66% and 4.52% in TCP of CTV-Low. For patients 3 and 4, with clinically comparable CTV dose coverages, the simulated online ART course achieved better OAR sparing than the offline ART course. The mean doses of right parotid and oral cavity were decreased from 29.52 Gy relative biological effectiveness (RBE) and 41.89 Gy RBE to 22.16 Gy RBE and 34.61 Gy RBE for patient 3, leading to a reduce of 1.67% and 3.40% in NTCP for the two organs. Compared to the current clinical practice, the retrospective study indicated that online APT tended to spare more normal tissues by achieving the clinical goal with merely half of the positional uncertainty margin. Future studies are needed to help identify the patients with large potential benefits prior to treatment to conserve scarce clinical resources.

physics.med-ph↗

Early in vivo Radiation Damage Quantification for Pediatric Craniospinal Irradiation Using Longitudinal MRI for Intensity Modulated Proton Therapy

Purpose: Proton vertebral body sparing craniospinal irradiation (VBS CSI) treats the thecal sac while avoiding the anterior vertebral bodies in effort to reduce myelosuppression and growth inhibition. However, robust treatment planning needs to compensate proton range uncertainty, contributing unwanted doses within the vertebral bodies. This work aims to develop an early in vivo radiation damage quantification method using longitudinal magnetic resonance (MR) scans to quantify dose effect during fractionated CSI. Materials and methods: Ten pediatric patients were enrolled in a prospective clinical trial of proton VBS CSI receiving 23.4-36 Gy. Monte Carlo robust planning was used with spinal clinical target volumes defined as the thecal sac and neural foramina. T1/T2-weighted MR scans were acquired before, during, and after treatments to detect transition from hematopoietic to less metabolically active fatty marrow. MR signal intensity histograms at each time point were analyzed and fitted by multi-Gaussian models to quantify radiation damages. Results: Fatty marrow filtration was observed on MR images as early as the fifth fraction of treatment. Maximum radiation-induced marrow damage occurred 40-50 days from the treatment start, followed by marrow regeneration. The mean damage ratios were 0.23, 0.41, 0.59, and 0.54 corresponding to 10, 20, 40, and 60 days from the treatment start. Conclusions: We demonstrated a non-invasive method to identify early vertebral marrow damage based on radiation-induced fatty marrow replacement. The proposed method can be potentially used to quantify the quality of CSI vertebral sparing to preserve metabolically active hematopoietic bone marrow.

physics.med-ph↗