SearcharxivSearch

arXiv subjects

Yingdi Liu

Publications and source records attributed to Yingdi Liu.

3 recordsLinked to original sources

Two New Stenosis Detection Methods of Coronary Angiograms

Coronary angiography is the "gold standard" for diagnosing coronary artery disease (CAD). At present, the methods for detecting and evaluating coronary artery stenosis cannot satisfy the clinical needs, e.g., there is no prior study of detecting stenoses in prespecified vessel segments, which is necessary in clinical practice. Two vascular stenosis detection methods are proposed to assist the diagnosis. The first one is an automatic method, which can automatically extract the entire coronary artery tree and mark all the possible stenoses. The second one is an interactive method. With this method, the user can choose any vessel segment to do further analysis of its stenoses. Experiments show that the proposed methods are robust for angiograms with various vessel structures. The precision, sensitivity, and $F_1$ score of the automatic stenosis detection method are 0.821, 0.757, and 0.788, respectively. Further investigation proves that the interactive method can provide a more precise outcome of stenosis detection, and our quantitative analysis is closer to reality. The proposed automatic method and interactive method are effective and can complement each other in clinical practice. The first method can be used for preliminary screening, and the second method can be used for further quantitative analysis. We believe the proposed solution is more suitable for the clinical diagnosis of CAD.

eess.IV

Two New Stenosis Detection Methods of Coronary Angiograms

Coronary angiography is the "gold standard" for diagnosing coronary artery disease (CAD). At present, the methods for detecting and evaluating coronary artery stenosis cannot satisfy the clinical needs, e.g., there is no prior study of detecting stenoses in prespecified vessel segments, which is necessary in clinical practice. Two vascular stenosis detection methods are proposed to assist the diagnosis. The first one is an automatic method, which can automatically extract the entire coronary artery tree and mark all the possible stenoses. The second one is an interactive method. With this method, the user can choose any vessel segment to do further analysis of its stenoses. Experiments show that the proposed methods are robust for angiograms with various vessel structures. The precision, sensitivity, and $F_1$ score of the automatic stenosis detection method are 0.821, 0.757, and 0.788, respectively. Further investigation proves that the interactive method can provide a more precise outcome of stenosis detection, and our quantitative analysis is closer to reality. The proposed automatic method and interactive method are effective and can complement each other in clinical practice. The first method can be used for preliminary screening, and the second method can be used for further quantitative analysis. We believe the proposed solution is more suitable for the clinical diagnosis of CAD.

eess.IV

Ab initio calculations of the atomic and electronic structures of crystalline PEO3:LiCF3SO3 electrolytes

The PEO3:LiCF3SO3 polymer electrolyte has attracted significant research due to its enhanced stability at the lithium/polymer interface of high conductivity polymer batteries. Experimental studies have shown that, depending on the preparation conditions, both the PEO3:LiCF3SO3 crystalline complex and the PEO3:LiCF3SO3 amorphous phase can be formed. However, previous theoretical investigations focused on the short chain amorphous PEO3:LiCF3SO3 system. We report ab initio density-functional-theory calculations of crystalline PEO3:LiCF3SO3. The calculated results about the bonding configuration, electronic structures, and conductivity properties are in good agreement with the experimental measurements.

cond-mat.mtrl-sci