SearcharxivSearch

arXiv subjects

Yinzhe Wu

Publications and source records attributed to Yinzhe Wu.

At least 19 recordsLinked to original sources

ReDiff: Reliability-Guided Diffusion for Trustworthy Ultra-Low-Field to High-Field MRI Synthesis

Low-field to high-field MRI synthesis has emerged as a promising strategy to improve image quality when access to high-field scanners is limited. However, in ultra-low-field settings, the degradation of anatomical detail is spatially heterogeneous: structurally ambiguous regions are more susceptible to unstable high-frequency generation, which may produce anatomically inconsistent textures and boundaries. This issue is particularly problematic when synthesized images are used for downstream quantitative analysis. We therefore study how to make diffusion-based LF-to-HF synthesis more spatially reliable, rather than only sharper on average. To this end, we propose a reliability-guided diffusion framework (ReDiff) with two complementary inference-time mechanisms. First, a reliability-guided sampling strategy attenuates unstable reverse-diffusion updates in regions with weak low-field support. Second, an uncertainty-aware candidate selection scheme aggregates multiple stochastic reconstructions according to spatial consensus and predictive uncertainty. Beyond aggregate image quality, we test whether the uncertainty is itself a usable reliability signal. Experiments on paired 64mT$\rightarrow$3T MRI datasets show that ReDiff attains the lowest LPIPS across three contrasts and two datasets while remaining competitive on PSNR and SSIM, and downstream segmentation analysis indicates better preservation of anatomical structure.

cs.CV

MoE-dqINR: A Unified Mixture-of-Experts Implicit Neural Representation Framework for Scan-Specific Dynamic and Quantitative MRI Reconstruction

Undersampled magnetic resonance imaging (MRI) reconstruction seeks to recover temporally or contrast-varying image series from incomplete multicoil k-space data while preserving state-dependent fidelity for dynamic and quantitative MRI (qMRI). Existing scan-specific implicit neural representations (INRs) often use monolithic spatiotemporal coordinate fields, explicit subspaces, motion or deformation models, calibration variables, or sequence-specific quantitative signal models. These design choices can limit flexibility in sharing spatial information while adapting image synthesis across acquisition states. Moreover, many INR-based baselines remain computationally demanding, typically requiring per-scan optimization times on the order of hundreds to thousands of seconds. We propose MoE-dqINR, a scan-specific multicoil MRI reconstruction framework that factorizes the image-domain representation into shared spatial experts and a state-conditioned routing pathway. Spatial experts encode reusable coordinate-dependent image content, whereas routing weights, conditioned on ordered acquisition states, synthesize each dynamic frame or contrast state from a common expert bank. The representation is coupled to a multicoil MRI forward model, uses the normalized state index to drive routing in both dynamic and quantitative MRI. By separating shared spatial representation from state-dependent synthesis, the framework provides an image-first architecture for dynamic and quantitative MRI while reducing scan-specific INR optimization to approximately 30 s per scan in our experiments. The proposed formulation establishes state-conditioned mixture-of-experts INR as a scan-specific multicoil MRI reconstruction prior that unifies shared spatial representation, dynamic- and qMRI-specific synthesis, and practical per-scan efficiency.

eess.IV

Real-Time Non-Invasive Imaging and Detection of Spreading Depolarizations through EEG: An Ultra-Light Explainable Deep Learning Approach

A core aim of neurocritical care is to prevent secondary brain injury. Spreading depolarizations (SDs) have been identified as an important independent cause of secondary brain injury. SDs are usually detected using invasive electrocorticography recorded at high sampling frequency. Recent pilot studies suggest a possible utility of scalp electrodes generated electroencephalogram (EEG) for non-invasive SD detection. However, noise and attenuation of EEG signals makes this detection task extremely challenging. Previous methods focus on detecting temporal power change of EEG over a fixed high-density map of scalp electrodes, which is not always clinically feasible. Having a specialized spectrogram as an input to the automatic SD detection model, this study is the first to transform SD identification problem from a detection task on a 1-D time-series wave to a task on a sequential 2-D rendered imaging. This study presented a novel ultra-light-weight multi-modal deep-learning network to fuse EEG spectrogram imaging and temporal power vectors to enhance SD identification accuracy over each single electrode, allowing flexible EEG map and paving the way for SD detection on ultra-low-density EEG with variable electrode positioning. Our proposed model has an ultra-fast processing speed (<0.3 sec). Compared to the conventional methods (2 hours), this is a huge advancement towards early SD detection and to facilitate instant brain injury prognosis. Seeing SDs with a new dimension - frequency on spectrograms, we demonstrated that such additional dimension could improve SD detection accuracy, providing preliminary evidence to support the hypothesis that SDs may show implicit features over the frequency profile.

eess.SP

High-Resolution Reference Image Assisted Volumetric Super-Resolution of Cardiac Diffusion Weighted Imaging

Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) is the only in vivo method to non-invasively examine the microstructure of the human heart. Current research in DT-CMR aims to improve the understanding of how the cardiac microstructure relates to the macroscopic function of the healthy heart as well as how microstructural dysfunction contributes to disease. To get the final DT-CMR metrics, we need to acquire diffusion weighted images of at least 6 directions. However, due to DWI's low signal-to-noise ratio, the standard voxel size is quite big on the scale for microstructures. In this study, we explored the potential of deep-learning-based methods in improving the image quality volumetrically (x4 in all dimensions). This study proposed a novel framework to enable volumetric super-resolution, with an additional model input of high-resolution b0 DWI. We demonstrated that the additional input could offer higher super-resolved image quality. Going beyond, the model is also able to super-resolve DWIs of unseen b-values, proving the model framework's generalizability for cardiac DWI superresolution. In conclusion, we would then recommend giving the model a high-resolution reference image as an additional input to the low-resolution image for training and inference to guide all super-resolution frameworks for parametric imaging where a reference image is available.

eess.IV

Self-Supervised Spatial And Zero-Shot Angular Super-Resolution by Spatial-Angular Implicit Representation For Rotating-View SNR-Efficient Diffusion MRI

Rotating-view thick-slice acquisition is highly SNR-efficient for mesoscale diffusion MRI (dMRI) but requires numerous rotating views to satisfy Nyquist sampling, resulting in long scan time. We propose a self-supervised Spatial-Angular Implicit Neural Representation (SA-INR) that reconstructs high-resolution dMRI from a single view per diffusion direction, representing a massive acceleration. Our model, an MLP conditioned on a b=0 structural prior and the b-direction via FiLM, is trained end-to-end on the anisotropic input. The framework not only accurately reconstructs the trained b-directions (spatial SR) but also learns a continuous q-space representation, enabling high-fidelity "zero-shot" synthesis of unseen b-directions (angular SR). On simulated data, our method achieved high fidelity for both trained (34.82 dB) and unseen (33.08 dB) directions. Most importantly, the synthesized angular data also improved the quantitative accuracy of downstream DTI model fitting. Our SA-INR framework breaks the classical sampling limits, paving the way for fast, quantitative high-resolution dMRI.

cs.CV

Enabling Ultra-Fast Cardiovascular Imaging Across Heterogeneous Clinical Environments with A Generalist Foundation Model and Multimodal Database

Multimodal cardiovascular magnetic resonance (CMR) imaging provides comprehensive and non-invasive insights into cardiovascular disease (CVD) diagnosis and underlying mechanisms. Despite decades of advancements, its widespread clinical adoption remains constrained by prolonged scan times, inconsistent image quality, and heterogeneity across medical environments. This underscores the urgent need for a generalist reconstruction foundation model for ultra-fast CMR imaging, one formulated for physics-constrained inverse problems in the sensor (k-space) domain, capable of adapting across diverse imaging scenarios and serving as the essential substrate for all downstream analyses. To enable this goal, we curate MMCMR-427K, the largest and most comprehensive multimodal CMR k-space database to date, comprising 427,465 multi-coil k-space data paired with structured metadata across 13 international centers, 12 CMR modalities, 15 scanners spanning four field strengths, and 17 CVD categories in populations across three continents. Building on this unprecedented resource, we introduce CardioMM, a generalist reconstruction foundation model capable of dynamically adapting to heterogeneous fast CMR imaging scenarios. CardioMM unifies semantic contextual understanding with physics-informed data consistency to deliver robust reconstructions across varied scanners, protocols, and patient presentations. Comprehensive evaluations demonstrate that CardioMM achieves state-of-the-art performance across internal centers and exhibits strong zero-shot generalization to unseen external settings. Importantly, CardioMM supports acceleration up to 24x, providing the first evidence that such extreme acquisition speed can preserve key cardiac phenotypes, quantitative myocardial biomarkers, and diagnostic image quality without compromising clinical integrity.

eess.IV

From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction

In motion-robust magnetic resonance imaging (MRI), slice-to-volume reconstruction is critical for recovering anatomically consistent 3D brain volumes from 2D slices, especially under accelerated acquisitions or patient motion. However, this task remains challenging due to hierarchical structural disruptions. It includes local detail loss from k-space undersampling, global structural aliasing caused by motion, and volumetric anisotropy. Therefore, we propose a progressive refinement implicit neural representation (PR-INR) framework. Our PR-INR unifies motion correction, structural refinement, and volumetric synthesis within a geometry-aware coordinate space. Specifically, a motion-aware diffusion module is first employed to generate coarse volumetric reconstructions that suppress motion artifacts and preserve global anatomical structures. Then, we introduce an implicit detail restoration module that performs residual refinement by aligning spatial coordinates with visual features. It corrects local structures and enhances boundary precision. Further, a voxel continuous-aware representation module represents the image as a continuous function over 3D coordinates. It enables accurate inter-slice completion and high-frequency detail recovery. We evaluate PR-INR on five public MRI datasets under various motion conditions (3% and 5% displacement), undersampling rates (4x and 8x) and slice resolutions (scale = 5). Experimental results demonstrate that PR-INR outperforms state-of-the-art methods in both quantitative reconstruction metrics and visual quality. It further shows generalization and robustness across diverse unseen domains.

eess.IV

Decoupling Multi-Contrast Super-Resolution: Self-Supervised Implicit Re-Representation for Unpaired Cross-Modal Synthesis

Multi-contrast super-resolution (MCSR) is crucial for enhancing MRI but current deep learning methods are limited. They typically require large, paired low- and high-resolution (LR/HR) training datasets, which are scarce, and are trained for fixed upsampling scales. While recent self-supervised methods remove the paired data requirement, they fail to leverage valuable population-level priors. In this work, we propose a novel, decoupled MCSR framework that resolves both limitations. We reformulate MCSR into two stages: (1) an unpaired cross-modal synthesis (uCMS) module, trained once on unpaired population data to learn a robust anatomical prior; and (2) a lightweight, patient-specific implicit re-representation (IrR) module. This IrR module is optimized in a self-supervised manner to fuse the population prior with the subject's own LR target data. This design uniquely fuses population-level knowledge with patient-specific fidelity without requiring any paired LR/HR or paired cross-modal training data. By building the IrR module on an implicit neural representation, our framework is also inherently scale-agnostic. Our method demonstrates superior quantitative performance on different datasets, with exceptional robustness at extreme scales (16x, 32x), a regime where competing methods fail. Our work presents a data-efficient, flexible, and computationally lightweight paradigm for MCSR, enabling high-fidelity, arbitrary-scale

cs.CV

Towards Modality- and Sampling-Universal Learning Strategies for Accelerating Cardiovascular Imaging: Summary of the CMRxRecon2024 Challenge

Cardiovascular health is vital to human well-being, and cardiac magnetic resonance (CMR) imaging is considered the {clinical reference standard} for diagnosing cardiovascular disease. However, its adoption is hindered by long scan times, complex contrasts, and inconsistent quality. While deep learning methods perform well on specific CMR imaging {sequences}, they often fail to generalize across modalities and sampling schemes. The lack of benchmarks for high-quality, fast CMR image reconstruction further limits technology comparison and adoption. The CMRxRecon2024 challenge, attracting over 200 teams from 18 countries, addressed these issues with two tasks: generalization to unseen {modalities} and robustness to diverse undersampling patterns. We introduced the largest public multi-{modality} CMR raw dataset, an open benchmarking platform, and shared code. Analysis of the best-performing solutions revealed that prompt-based adaptation and enhanced physics-driven consistency enabled strong cross-scenario performance. These findings establish principles for generalizable reconstruction models and advance clinically translatable AI in cardiovascular imaging.

eess.IV

Cyclic Self-Supervised Diffusion for Ultra Low-field to High-field MRI Synthesis

Synthesizing high-quality images from low-field MRI holds significant potential. Low-field MRI is cheaper, more accessible, and safer, but suffers from low resolution and poor signal-to-noise ratio. This synthesis process can reduce reliance on costly acquisitions and expand data availability. However, synthesizing high-field MRI still suffers from a clinical fidelity gap. There is a need to preserve anatomical fidelity, enhance fine-grained structural details, and bridge domain gaps in image contrast. To address these issues, we propose a \emph{cyclic self-supervised diffusion (CSS-Diff)} framework for high-field MRI synthesis from real low-field MRI data. Our core idea is to reformulate diffusion-based synthesis under a cycle-consistent constraint. It enforces anatomical preservation throughout the generative process rather than just relying on paired pixel-level supervision. The CSS-Diff framework further incorporates two novel processes. The slice-wise gap perception network aligns inter-slice inconsistencies via contrastive learning. The local structure correction network enhances local feature restoration through self-reconstruction of masked and perturbed patches. Extensive experiments on cross-field synthesis tasks demonstrate the effectiveness of our method, achieving state-of-the-art performance (e.g., 31.80 $\pm$ 2.70 dB in PSNR, 0.943 $\pm$ 0.102 in SSIM, and 0.0864 $\pm$ 0.0689 in LPIPS). Beyond pixel-wise fidelity, our method also preserves fine-grained anatomical structures compared with the original low-field MRI (e.g., left cerebral white matter error drops from 12.1$\%$ to 2.1$\%$, cortex from 4.2$\%$ to 3.7$\%$). To conclude, our CSS-Diff can synthesize images that are both quantitatively reliable and anatomically consistent.

cs.CV

Lightweight Hypercomplex MRI Reconstruction: A Generalized Kronecker-Parameterized Approach

Magnetic Resonance Imaging (MRI) is crucial for clinical diagnostics but is hindered by prolonged scan times. Current deep learning models enhance MRI reconstruction but are often memory-intensive and unsuitable for resource-limited systems. This paper introduces a lightweight MRI reconstruction model leveraging Kronecker-Parameterized Hypercomplex Neural Networks to achieve high performance with reduced parameters. By integrating Kronecker-based modules, including Kronecker MLP, Kronecker Window Attention, and Kronecker Convolution, the proposed model efficiently extracts spatial features while preserving representational power. We introduce Kronecker U-Net and Kronecker SwinMR, which maintain high reconstruction quality with approximately 50% fewer parameters compared to existing models. Experimental evaluation on the FastMRI dataset demonstrates competitive PSNR, SSIM, and LPIPS metrics, even at high acceleration factors (8x and 16x), with no significant performance drop. Additionally, Kronecker variants exhibit superior generalization and reduced overfitting on limited datasets, facilitating efficient MRI reconstruction on hardware-constrained systems. This approach sets a new benchmark for parameter-efficient medical imaging models.

eess.IV

Enhancing Diffusion-Weighted Images (DWI) for Diffusion MRI: Is it Enough without Non-Diffusion-Weighted B=0 Reference?

Diffusion MRI (dMRI) is essential for studying brain microstructure, but high-resolution imaging remains challenging due to the inherent trade-offs between acquisition time and signal-to-noise ratio (SNR). Conventional methods often optimize only the diffusion-weighted images (DWIs) without considering their relationship with the non-diffusion-weighted (b=0) reference images. However, calculating diffusion metrics, such as the apparent diffusion coefficient (ADC) and diffusion tensor with its derived metrics like fractional anisotropy (FA) and mean diffusivity (MD), relies on the ratio between each DWI and the b=0 image, which is crucial for clinical observation and diagnostics. In this study, we demonstrate that solely enhancing DWIs using a conventional pixel-wise mean squared error (MSE) loss is insufficient, as the error in ratio between generated DWIs and b=0 diverges. We propose a novel ratio loss, defined as the MSE loss between the predicted and ground-truth log of DWI/b=0 ratios. Our results show that incorporating the ratio loss significantly improves the convergence of this ratio error, achieving lower ratio MSE and slightly enhancing the peak signal-to-noise ratio (PSNR) of generated DWIs. This leads to improved dMRI super-resolution and better preservation of b=0 ratio-based features for the derivation of diffusion metrics.

eess.IV

Spreading Depolarization Detection in Electrocorticogram Spectrogram Imaging by Deep Learning: Is It Just About Delta Band?

Prevention of secondary brain injury is a core aim of neurocritical care, with Spreading Depolarizations (SDs) recognized as a significant independent cause. SDs are typically monitored through invasive, high-frequency electrocorticography (ECoG); however, detection remains challenging due to signal artifacts that obscure critical SD-related electrophysiological changes, such as power attenuation and DC drifting. Recent studies suggest spectrogram analysis could improve SD detection; however, brain injury patients often show power reduction across all bands except delta, causing class imbalance. Previous methods focusing solely on delta mitigates imbalance but overlooks features in other frequencies, limiting detection performance. This study explores using multi-frequency spectrogram analysis, revealing that essential SD-related features span multiple frequency bands beyond the most active delta band. This study demonstrated that further integration of both alpha and delta bands could result in enhanced SD detection accuracy by a deep learning model.

eess.SP

RSFR: A Coarse-to-Fine Reconstruction Framework for Diffusion Tensor Cardiac MRI with Semantic-Aware Refinement

Cardiac diffusion tensor imaging (DTI) offers unique insights into cardiomyocyte arrangements, bridging the gap between microscopic and macroscopic cardiac function. However, its clinical utility is limited by technical challenges, including a low signal-to-noise ratio, aliasing artefacts, and the need for accurate quantitative fidelity. To address these limitations, we introduce RSFR (Reconstruction, Segmentation, Fusion & Refinement), a novel framework for cardiac diffusion-weighted image reconstruction. RSFR employs a coarse-to-fine strategy, leveraging zero-shot semantic priors via the Segment Anything Model and a robust Vision Mamba-based reconstruction backbone. Our framework integrates semantic features effectively to mitigate artefacts and enhance fidelity, achieving state-of-the-art reconstruction quality and accurate DT parameter estimation under high undersampling rates. Extensive experiments and ablation studies demonstrate the superior performance of RSFR compared to existing methods, highlighting its robustness, scalability, and potential for clinical translation in quantitative cardiac DTI.

eess.IV

Is fitting error a reliable metric for assessing deformable motion correction in quantitative MRI?

Quantitative MR (qMR) can provide numerical values representing the physical and chemical properties of the tissues. To collect a series of frames under varying settings, retrospective motion correction is essential to align the corresponding anatomical points or features. Under the assumption that the misalignment makes the discrepancy between the corresponding features larger, fitting error is a commonly used evaluation metric for motion correction in qMR. This study evaluates the reliability of the fitting error metric in cardiac diffusion tensor imaging (cDTI) after deformable registration. We found that while fitting error correlates with the negative eigenvalues, the negative Jacobian Determinant increases with broken cardiomyocytes, indicated by helix angle gradient line profiles. Since fitting error measures the distance between moved points and their re-rendered counterparts, the fitting parameter itself may be adjusted due to poor registration. Therefore, fitting error in deformable registration itself is a necessary but not sufficient metric and should be combined with other metrics.

physics.med-ph

When AI Eats Itself: On the Caveats of AI Autophagy

Generative Artificial Intelligence (AI) technologies and large models are producing realistic outputs across various domains, such as images, text, speech, and music. Creating these advanced generative models requires significant resources, particularly large and high-quality datasets. To minimise training expenses, many algorithm developers use data created by the models themselves as a cost-effective training solution. However, not all synthetic data effectively improve model performance, necessitating a strategic balance in the use of real versus synthetic data to optimise outcomes. Currently, the previously well-controlled integration of real and synthetic data is becoming uncontrollable. The widespread and unregulated dissemination of synthetic data online leads to the contamination of datasets traditionally compiled through web scraping, now mixed with unlabeled synthetic data. This trend, known as the AI autophagy phenomenon, suggests a future where generative AI systems may increasingly consume their own outputs without discernment, raising concerns about model performance, reliability, and ethical implications. What will happen if generative AI continuously consumes itself without discernment? What measures can we take to mitigate the potential adverse effects? To address these research questions, this study examines the existing literature, delving into the consequences of AI autophagy, analyzing the associated risks, and exploring strategies to mitigate its impact. Our aim is to provide a comprehensive perspective on this phenomenon advocating for a balanced approach that promotes the sustainable development of generative AI technologies in the era of large models.

cs.LG

Data and Physics driven Deep Learning Models for Fast MRI Reconstruction: Fundamentals and Methodologies

Magnetic Resonance Imaging (MRI) is a pivotal clinical diagnostic tool, yet its extended scanning times often compromise patient comfort and image quality, especially in volumetric, temporal and quantitative scans. This review elucidates recent advances in MRI acceleration via data and physics-driven models, leveraging techniques from algorithm unrolling models, enhancement-based methods, and plug-and-play models to the emerging full spectrum of generative model-based methods. We also explore the synergistic integration of data models with physics-based insights, encompassing the advancements in multi-coil hardware accelerations like parallel imaging and simultaneous multi-slice imaging, and the optimization of sampling patterns. We then focus on domain-specific challenges and opportunities, including image redundancy exploitation, image integrity, evaluation metrics, data heterogeneity, and model generalization. This work also discusses potential solutions and future research directions, with an emphasis on the role of data harmonization and federated learning for further improving the general applicability and performance of these methods in MRI reconstruction.

eess.SP

Explicit Differentiable Slicing and Global Deformation for Cardiac Mesh Reconstruction

Mesh reconstruction of the cardiac anatomy from medical images is useful for shape and motion measurements and biophysics simulations to facilitate the assessment of cardiac function and health. However, 3D medical images are often acquired as 2D slices that are sparsely sampled and noisy, and mesh reconstruction on such data is a challenging task. Traditional voxel-based approaches rely on pre- and post-processing that compromises image fidelity, while mesh-level deep learning approaches require mesh annotations that are difficult to get. Therefore, direct cross-domain supervision from 2D images to meshes is a key technique for advancing 3D learning in medical imaging, but it has not been well-developed. While there have been attempts to approximate the optimized meshes' slicing, few existing methods directly use 2D slices to supervise mesh reconstruction in a differentiable manner. Here, we propose a novel explicit differentiable voxelization and slicing (DVS) algorithm that allows gradient backpropagation to a mesh from its slices, facilitating refined mesh optimization directly supervised by the losses defined on 2D images. Further, we propose an innovative framework for extracting patient-specific left ventricle (LV) meshes from medical images by coupling DVS with a graph harmonic deformation (GHD) mesh morphing descriptor of cardiac shape that naturally preserves mesh quality and smoothness during optimization. Experimental results demonstrate that our method achieves state-of-the-art performance in cardiac mesh reconstruction tasks from CT and MRI, with an overall Dice score of 90% on multi-datasets, outperforming existing approaches. The proposed method can further quantify clinically useful parameters such as ejection fraction and global myocardial strains, closely matching the ground truth and surpassing the traditional voxel-based approach in sparse images.

eess.IV