Searcharxiv⌕ Search

arXiv subjects

Yiqiu Ma

Publications and source records attributed to Yiqiu Ma.

51 records · Page 3Linked to original sources

Coherent coupling completes an unambiguous optomechanical classification framework

In most optomechanical systems a movable mirror is a part of an optical cavity, and its oscillation modulates either the resonance frequency of the cavity, or its coupling to the environment. There exists the third option -- which we call a "coherent coupling" -- when the mechanical oscillation couples several non-degenerate optical modes supported by the cavity. Identifying the nature of the coupling can be an important step in designing the setup for a specific application. In order to unambiguously distinguish between different optomechanical couplings, we develop a general framework based on the Hamiltonian of the system. Using this framework we give examples of different couplings, and discuss in details one particular case of a purely coherent coupling in a ring cavity with a movable mirror inside. We demonstrate that in certain cases coherent coupling can be beneficial for cooling the motion of the mechanical oscillator. Our general framework allows to approach the design of optomechanical experiments in a methodological way, for precise exploitation of the strengths of particular optomechanical couplings.

quant-ph↗

Quantum expander for gravitational-wave observatories

Quantum uncertainty of laser light limits the sensitivity of gravitational-wave observatories. In the past 30 years, techniques for squeezing the quantum uncertainty as well as for enhancing the gravitational-wave signal with optical resonators were invented. Resonators, however, have finite linewidths; and the high signal frequencies that are produced during the scientifically highly interesting ring-down of astrophysical compact-binary mergers cannot be resolved today. Here, we propose an optical approach for expanding the detection bandwidth. It uses quantum uncertainty squeezing inside one of the optical resonators, compensating for finite resonators' linewidths while maintaining the low-frequency sensitivity unchanged. Introducing the quantum expander for boosting the sensitivity of future gravitational-wave detectors, we envision it to become a new tool in other cavity-enhanced metrological experiments.

quant-ph↗

Instability of exotic compact objects and its implications for gravitational-wave echoes

Exotic compact objects (ECOs) have recently become an exciting research subject, since they are speculated to have a special response to the incident gravitational waves (GWs) that leads to GW echoes. We show that energy carried by GWs can easily cause the event horizon to form out of a static ECO --- leaving no echo signals towards spatial infinity. To show this, we use the ingoing Vaidya spacetime and take into account the back reaction due to incoming GWs. Demanding that an ECO does not collapse into a black hole puts an upper bound on the compactness of the ECO, at the cost of less distinct echo signals for smaller compactness. The trade-off between echoes' detectability and distinguishability leads to a fine tuning of ECO parameters for LIGO to find distinct echoes. We also show that an extremely compact ECO that can survive the gravitational collapse and give rise to GW echoes might have to expand its surface in a non-causal way.

gr-qc↗

Towards the Fundamental Quantum Limit of Linear Measurements of Classical Signals

The quantum Cramér-Rao bound (QCRB) sets a fundamental limit for the measurement of classical signals with detectors operating in the quantum regime. Using linear-response theory and the Heisenberg uncertainty relation, we derive a general condition for achieving such a fundamental limit. When applied to classical displacement measurements with a test mass, this condition leads to an explicit connection between the QCRB and the Standard Quantum Limit which arises from a tradeoff between the measurement imprecision and quantum backaction; the QCRB can be viewed as an outcome of a quantum non-demolition measurement with the backaction evaded. Additionally, we show that the test mass is more a resource for improving measurement sensitivity than a victim of the quantum backaction, which suggests a new approach to enhancing the sensitivity of a broad class of sensors. We illustrate these points with laser interferometric gravitational wave detectors.

quant-ph↗

Proposal for Gravitational-Wave Detection Beyond the Standard Quantum Limit via EPR Entanglement

The Standard Quantum Limit in continuous monitoring of a system is given by the trade-off of shot noise and back-action noise. In gravitational-wave detectors, such as Advanced LIGO, both contributions can simultaneously be squeezed in a broad frequency band by injecting a spectrum of squeezed vacuum states with a frequency-dependent squeeze angle. This approach requires setting up an additional long base-line, low-loss filter cavity in a vacuum system at the detector's site. Here, we show that the need for such a filter cavity can be eliminated, by exploiting EPR-entangled signal and idler beams. By harnessing their mutual quantum correlations and the difference in the way each beam propagates in the interferometer, we can engineer the input signal beam to have the appropriate frequency dependent conditional squeezing once the out-going idler beam is detected. Our proposal is appropriate for all future gravitational-wave detectors for achieving sensitivities beyond the Standard Quantum Limit.

quant-ph↗

Towards thermal noise free optomechanics

Thermal noise generally greatly exceeds quantum noise in optomechanical devices unless the mechanical frequency is very high or the thermodynamic temperature is very low. This paper addresses the design concept for a novel optomechanical device capable of ultrahigh quality factors in the audio frequency band with negligible thermal noise. The proposed system consists of a minimally supported millimeter scale pendulum mounted in a Double End-Mirror Sloshing (DEMS) cavity that is topologically equivalent to a Membrane-in-the-Middle (MIM) cavity. The radiation pressure inside the high-finesse cavity allows for high optical stiffness, cancellation of terms which lead to unwanted negative damping and suppression of quantum radiation pressure noise. We solve for the optical spring dynamics of the system using the Hamiltonian, find the noise spectral density and show that stable optical trapping is possible. We also assess various loss mechanisms, one of the most important being the acceleration loss due to the optical spring. We show that practical devices, starting from a centre-of-mass pendulum frequency of 0.1 Hz, could achieve a maximum quality factor of $10^{14}$ with optical spring stiffened frequency 1-10 kHz. Small resonators of mass 1 $μ$g or less could achieve a Q-factor of $10^{11}$ at a frequency of 100 kHz. Applications for such devices include white light cavities for improvement of gravitational wave detectors, or sensors able to operate near the quantum limit.

physics.optics↗

The next detectors for gravitational wave astronomy

This paper focuses on the next detectors for gravitational wave astronomy which will be required after the current ground based detectors have completed their initial observations, and probably achieved the first direct detection of gravitational waves. The next detectors will need to have greater sensitivity, while also enabling the world array of detectors to have improved angular resolution to allow localisation of signal sources. Sect. 1 of this paper begins by reviewing proposals for the next ground based detectors, and presents an analysis of the sensitivity of an 8 km armlength detector, which is proposed as a safe and cost-effective means to attain a 4-fold improvement in sensitivity. The scientific benefits of creating a pair of such detectors in China and Australia is emphasised. Sect. 2 of this paper discusses the high performance suspension systems for test masses that will be an essential component for future detectors, while sect. 3 discusses solutions to the problem of Newtonian noise which arise from fluctuations in gravity gradient forces acting on test masses. Such gravitational perturbations cannot be shielded, and set limits to low frequency sensitivity unless measured and suppressed. Sects. 4 and 5 address critical operational technologies that will be ongoing issues in future detectors. Sect. 4 addresses the design of thermal compensation systems needed in all high optical power interferometers operating at room temperature. Parametric instability control is addressed in sect. 5. Only recently proven to occur in Advanced LIGO, parametric instability phenomenon brings both risks and opportunities for future detectors. The path to future enhancements of detectors will come from quantum measurement technologies. Sect. 6 focuses on the use of optomechanical devices for obtaining enhanced sensitivity, while sect. 7 reviews a range of quantum measurement options.

physics.ins-det↗

Enhancing the bandwidth of gravitational-wave detectors with unstable optomechanical filters

For gravitational-wave interferometric detectors, there is a tradeoff between the detector bandwidth and peak sensitivity when focusing on the shot noise level. This has to do with the frequency-dependent propagation phase lag (positive dispersion) of the signal. We consider embedding an active unstable filter---a cavity-assisted optomechanical device operating in the instability regime---inside the interferometer to compensate the phase, and using feedback control to stabilize the entire system. We show that this scheme in principle can enhance the bandwidth without sacrificing the peak sensitivity. However, there is one practical difficulty for implementing it due to the thermal fluctuation of the mechanical oscillator in the optomechanical filter, which puts a very stringent requirement on the environmental temperature and the mechanical quality factor.

quant-ph↗

Photons with sub-Planckian Energy Cannot Efficiently Probe Space-Time Foam

Extra-galactic sources of photons have been used to constrain space-time quantum fluctuations in the Universe. In these proposals, the fundamental "fuzziness" of distance caused by space-time quantum fluctuations has been directly identified with fluctuations in optical paths. Phase-front corrugations deduced from these optical-path fluctuations are then applied to light from extra-galactic point sources, and used to constrain various models of quantum gravity. However, when a photon propagates in three spatial dimensions, it does not follow a specific ray, but rather samples a finite, three-dimensional region around that ray --- thereby averaging over space-time quantum fluctuations all through that region. We use a simple, random-walk type model to demonstrate that, once the appropriate wave optics is applied, the averaging of neighboring space-time fluctuations will cause much less distortion to the phase front. In our model, the extra suppression factor due to diffraction is the wave length in units of the Planck length, which is at least $10^{29}$ for astronomical observations.

astro-ph.HE↗

Linear negative dispersion with a gain doublet via optomechanical interactions

Optical cavities containing a negative dispersion medium have been proposed as a means of improving the sensitivity of laser interferometric gravitational wave (GW) detectors through the creation of white light signal recycling cavities. Here we classically demonstrate that negative dispersion can be realized using an optomechanical cavity pumped by a blue detuned doublet. We used an 85mm cavity with an intra-cavity silicon nitride membrane. Tunable negative dispersion is demonstrated, with a phase derivative $dφ/df$ from $-0.14$ Deg$\cdot$Hz$^{-1}$ to $-4.2\times10^{-3}$ Deg$\cdot$Hz$^{-1}$.

physics.optics↗

Quantum noise of white light cavity using double-pumped gain medium

Laser interferometric gravitational-wave detectors implement Fabry-Perot cavities to increase their peak sensitivity. However, this is at cost of reducing their detection bandwidth, which origins from the propagation phase delay of the light. The "white-light-cavity" idea, first proposed by Wicht et al. [Optics Communications 134, 431 (1997)], is to circumvent this limitation by introducing anomalous dispersion, using double-pumped gain medium, to compensate for such phase delay. In this article, starting from the Hamiltonian of atom-light interaction, we apply the input-output formalism to evaluate the quantum noise of the system. We find that apart from the additional noise associated with the parametric amplification process noticed by others, the stability condition for the entire system poses an additional constraint. Through surveying the parameter regimes where the gain medium remains stable (not lasing) and stationary, we find that there is no net enhancement of the shot-noise limited sensitivity. Therefore, other gain mediums or different parameter regimes shall be explored for realizing the white light cavity.

quant-ph↗

Extraction of energy from gravitational waves by laser interferometer detectors

In this paper we discuss the energy interaction between gravitational waves and laser interferom- eter gravitational wave detectors. We show that the widely held view that the laser interferometer gravitational wave detector absorbs no energy from gravitational waves is only valid under the approximation of a frequency-independent optomechanical coupling strength and a pump laser without detuning with respect to the resonance of the interferometer. For a strongly detuned interferometer, the optical-damping dynamics dissipates gravitational wave energy through the interaction between the test masses and the optical field. For a non-detuned interferometer, the frequency-dependence of the optomechanical coupling strength causes a tiny energy dissipation, which is proved to be equivalent to the Doppler friction raised by Braginsky et.al.

physics.optics↗

Narrowing the filter cavity bandwidth via optomechanical interaction

We propose using optomechanical interaction to narrow the bandwidth of filter cavities for achieving frequency-dependent squeezing in advanced gravitational-wave detectors, inspired by the idea of optomechanically induced transparency. This not only allows us to achieve narrow bandwidth, comparable to the detection band of few hundred Hz, with tabletop optical cavities, but also to tune the bandwidth over a wide range, which is ideal for optimizing sensitivity for different gravitational-wave sources. The experimental challenge for its implementation is the stringent requirement on low thermal noise, which would need superb mechanical quality factor that is quite difficult to achieve by using currently-available low-loss mechanical oscillators; one possible solution is to use optical dilution of the mechanical damping, which can considerably relax the requirement on the mechanics.

quant-ph↗

Three mode interaction noise in laser interferometer gravitational wave detectors

Triply resonant three mode interactions in long optical cavities have been shown to lead to enhanced scattering of carrier light by the ultrasonic acoustic modes of the test mass mirrors. At high optical power, this can lead to parametric instability (parametric gain R > 1) for a few acoustic modes with strong spectral and spatial overlap. Numerous ?~10^3 acoustic modes of the test masses are predicted to have R > 10^2. Experimental studies have shown that such modes also strongly scatter the carrier light, enabling very sensitive readout of the acoustic modes. The 3-mode scattering from the thermal fluctuation of large population of ultrasonic modes would causes random changes in occupation number of the carrier light and cavity transverse optical modes. Because the thermal fluctuation time scale (set by the acoustic mode relaxation times) is typically a few seconds, the noise spectrum from thermally induced photon number fluctuations is strongly peaked at low frequency. The noise level depends on the acoustic mode structure and acoustic losses of the test masses, the transverse optical mode spectrum of the optical cavities and on the test mass temperature. We theoretically investigate the possible effect of this noise and show that in advanced detectors under construction three mode interaction noise is below the standard quantum limit, but could set limits on future low frequency detectors that aim to exceed the free mass standard quantum limit.

physics.optics↗

Classical demonstration of frequency dependent noise ellipse rotation using Optomechanically Induced Transparency

Cavities with extremely narrow linewidth of 10-100 Hz are required for realizing frequency dependent squeezing to enable gravitational wave detectors to surpass the free mass standard quantum limit over a broad frequency range. Hundred-meter-scale high finesse cavities have been proposed for this purpose. Optomechanically induced transparency (OMIT) enables the creation of optomechanical cavities in which the linewidth limit is set by the extremely narrow linewidth of a high Q factor mechanical resonator. Using an 85mm OMIT cavity with a silicon nitride membrane, we demonstrate a tunable linewidth from 3Hz up to several hundred Hz and frequency dependent noise ellipse rotation using classical light with squeezed added noise to simulate quantum squeezed light. The frequency dependent noise ellipse angle is rotated in close agreement with predictions.

quant-ph↗