SearcharxivSearch

arXiv subjects

Yiwei Zou

Publications and source records attributed to Yiwei Zou.

7 recordsLinked to original sources

An Efficient Power Management Unit With Continuous MPPT and Energy Recycling for Wireless Millimetric Biomedical Implants

Biomedical implants offer transformative tools to improve medical outcomes. To realize minimally invasive implants with miniaturized volume and weight, wireless power transfer has been extensively studied to replace bulky batteries that dominate the volume of traditional implants and require surgical replacements. Ultra-sonic and magnetoelectric WPT modalities, which leverage low frequency acoustic electrical coupling for energy transduction, become viable solutions for mm-scale receivers. This work presents a fully integrated power management unit for ME WPT in millimetric implants. The PMU achieves load independent maximum power extraction and usage by continuously matching the impedance of the transducer, dynamically optimizing the power stage across varying input divided by load conditions, and reusing the storage energy to sustain the system when input power drops. Its parallel-input regulation and storing stages architecture prevent the cascading power loss. With the skewed-duty-cycle MPPT technique and regulation efficiency optimizer, the PMU achieves a peak MPPT efficiency of 98.5 percent and a peak system overall efficiency of 73.33 percent. Additionally, the PMU includes an adaptive high-voltage charging stage that charges the stimulation capacitor up to 12 V with an improved efficiency of 37.88 percent.

eess.SY

PowerGenie: Analytically-Guided Evolutionary Discovery of Superior Reconfigurable Power Converters

Discovering superior circuit topologies requires navigating an exponentially large design space-a challenge traditionally reserved for human experts. Existing AI methods either select from predefined templates or generate novel topologies at a limited scale without rigorous verification, leaving large-scale performance-driven discovery underexplored. We present PowerGenie, a framework for automated discovery of higher-performance reconfigurable power converters at scale. PowerGenie introduces: (1) an automated analytical framework that determines converter functionality and theoretical performance limits without component sizing or SPICE simulation, and (2) an evolutionary finetuning method that co-evolves a generative model with its training distribution through fitness selection and uniqueness verification. Unlike existing methods that suffer from mode collapse and overfitting, our approach achieves higher syntax validity, function validity, novelty rate, and figure-of-merit (FoM). PowerGenie discovers a novel 8-mode reconfigurable converter with 23% higher FoM than the best training topology. SPICE simulations confirm average absolute efficiency gains of 10% across 8 modes and up to 17% at a single mode. Code will be released upon publication.

cs.LG

Compressive Sensing Photoacoustic Imaging Receiver with Matrix-Vector-Multiplication SAR ADC

Wearable photoacoustic imaging devices hold great promise for continuous health monitoring and point-of-care diagnostics. However, the large data volume generated by high-density transducer arrays presents a major challenge for realizing compact and power-efficient wearable systems. This paper presents a photoacoustic imaging receiver (RX) that embeds compressive sensing directly into the hardware to address this bottleneck. The RX integrates 16 AFEs and four matrix-vector-multiplication (MVM) SAR ADCs that perform energy- and area-efficient analog-domain compression. The architecture achieves a 4-8x reduction in output data rate while preserving low-loss full-array information. The MVM SAR ADC executes passive and accurate MVM using user-defined programmable ternary weights. Two signal reconstruction methods are implemented: (1) an optimization approach using the fast iterative shrinkage-thresholding algorithm, and (2) a learning-based approach employing implicit neural representation. Fabricated in 65 nm CMOS, the chip achieves an ADC's SNDR of 57.5 dB at 20.41 MS/s, with an AFE input-referred noise of 3.5 nV/sqrt(Hz). MVM linearity measurements show R^2 > 0.999 across a wide range of weights and input amplitudes. The system is validated through phantom imaging experiments, demonstrating high-fidelity image reconstruction under up to 8x compression. The RX consumes 5.83 mW/channel and supports a general ternary-weighted measurement matrix, offering a compelling solution for next-generation miniaturized, wearable PA imaging systems.

eess.IV

A Miniature Batteryless Bioelectronic Implant Using One Magnetoelectric Transducer for Wireless Powering and PWM Backscatter Communication

Wireless minimally invasive bioelectronic implants enable a wide range of applications in healthcare, medicine, and scientific research. Magnetoelectric (ME) wireless power transfer (WPT) has emerged as a promising approach for powering miniature bio-implants because of its remarkable efficiency, safety limit, and misalignment tolerance. However, achieving low-power and high-quality uplink communication using ME remains a challenge. This paper presents a pulse-width modulated (PWM) ME backscatter uplink communication enabled by a switched-capacitor energy extraction (SCEE) technique. The SCEE rapidly extracts and dissipates the kinetic energy within the ME transducer during its ringdown period, enabling time-domain PWM in ME backscatter. Various circuit techniques are presented to realize SCEE with low power consumption. This paper also describes the high-order modeling of ME transducers to facilitate the design and analysis, which shows good matching with measurement. Our prototyping system includes a millimeter-scale ME implant with a fully integrated system-on-chip (SoC) and a portable transceiver for power transfer and bidirectional communication. SCEE is proven to induce >50% amplitude reduction within 2 ME cycles, leading to a PWM ME backscatter uplink with 17.73 kbps data rate and 0.9 pJ/bit efficiency. It also achieves 8.5 x 10 -5 bit-error-rate (BER) at a 5 cm distance, using a lightweight multi-layer-perception (MLP) decoding algorithm. Finally, the system demonstrates continuous wireless neural local-field potential (LFP) recording in an in vitro setup.

eess.SY

Omnidirectional Wireless Power Transfer for Millimetric Magnetoelectric Biomedical Implants

Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in devices. Despite successful demonstrations of millimetric battery free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery. This article presents an omnidirectional WPT platform for millimetric bioelectronic implants, employing the emerging magnetoelectric (ME) WPT modality, and magnetic field steering technique based on multiple transmitter (TX) coils. To accurately sense the weak coupling in a miniature implant and adaptively control the multicoil TX array in a closed loop, we develop an active echo (AE) scheme using a tiny coil on the implant. Our prototype comprises a fully integrated 14.2 mm3 implantable stimulator embedding a custom low power system on chip (SoC) powered by an ME film, a TX with a custom three channel AE RX chip, and a multicoil TX array with mutual inductance cancellation. The AE RX achieves negative 161 dBm per Hz input referred noise with 64 dB gain tuning range to reliably sense the AE signal, and offers fast polarity detection for driver control. AE simultaneously enhances the robustness, efficiency, and charging range of ME WPT. Under 90 degree rotation from the ideal position, our omnidirectional WPT system achieves 6.8x higher power transfer efficiency (PTE) than a single coil baseline. The tracking error of AE negligibly degrades the PTE by less than 2 percent from using ideal control.

eess.SY

PICO-RAM: A PVT-Insensitive Analog Compute-In-Memory SRAM Macro with In-Situ Multi-Bit Charge Computing and 6T Thin-Cell-Compatible Layout

Analog compute-in-memory (CIM) in static random-access memory (SRAM) is promising for accelerating deep learning inference by circumventing the memory wall and exploiting ultra-efficient analog low-precision arithmetic. Latest analog CIM designs attempt bit-parallel schemes for multi-bit analog Matrix-Vector Multiplication (MVM), aiming at higher energy efficiency, throughput, and training simplicity and robustness over conventional bit-serial methods that digitally shift-and-add multiple partial analog computing results. However, bit-parallel operations require more complex analog computations and become more sensitive to well-known analog CIM challenges, including large cell areas, inefficient and inaccurate multi-bit analog operations, and vulnerability to PVT variations. This paper presents PICO-RAM, a PVT-insensitive and compact CIM SRAM macro with charge-domain bit-parallel computation. It adopts a multi-bit thin-cell Multiply-Accumulate (MAC) unit that shares the same transistor layout as the most compact 6T SRAM cell. All analog computing modules, including digital-to-analog converters (DACs), MAC units, analog shift-and-add, and analog-to-digital converters (ADCs) reuse one set of local capacitors inside the array, performing in-situ computation to save area and enhance accuracy. A compact 8.5-bit dual-threshold time-domain ADC power gates the main path most of the time, leading to a significant energy reduction. Our 65-nm prototype achieves the highest weight storage density of 559 Kb/mm${^2}$ and exceptional robustness to temperature and voltage variations (-40 to 105 $^{\circ}$C and 0.65 to 1.2 V) among SRAM-based analog CIM designs.

cs.AR

Node Centrality Approximation For Large Networks Based On Inductive Graph Neural Networks

Closeness Centrality (CC) and Betweenness Centrality (BC) are crucial metrics in network analysis, providing essential reference for discerning the significance of nodes within complex networks. These measures find wide applications in critical tasks, such as community detection and network dismantling. However, their practical implementation on extensive networks remains computationally demanding due to their high time complexity. To mitigate these computational challenges, numerous approximation algorithms have been developed to expedite the computation of CC and BC. Nevertheless, even these approximations still necessitate substantial processing time when applied to large-scale networks. Furthermore, their output proves sensitive to even minor perturbations within the network structure. In this work, We redefine the CC and BC node ranking problem as a machine learning problem and propose the CNCA-IGE model, which is an encoder-decoder model based on inductive graph neural networks designed to rank nodes based on specified CC or BC metrics. We incorporate the MLP-Mixer model as the decoder in the BC ranking prediction task to enhance the model's robustness and capacity. Our approach is evaluated on diverse synthetic and real-world networks of varying scales, and the experimental results demonstrate that the CNCA-IGE model outperforms state-of-the-art baseline models, significantly reducing execution time while improving performance.

cs.SI