SearcharxivSearch

arXiv subjects

Yoichi Aso

Publications and source records attributed to Yoichi Aso.

At least 19 recordsLinked to original sources

Demonstration of length control for a filter cavity with coherent control sidebands

For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique and will be implemented in Advanced LIGO and Advanced Virgo in the fourth observing run. To obtain the benefit of frequency-dependent squeezing, the length and alignment of the filter cavity with respect to the squeezed vacuum field must be accurately controlled. To this purpose, a new length and alignment control scheme for a filter cavity, using coherent control sidebands, was suggested [Phys. Rev. D 102, 042003 (2020)]. The coherent control sidebands are already used to control the squeezing angle in squeezed vacuum sources for gravitational-wave detectors. As both the squeezed vacuum field and coherent control sidebands have the same mode-matching conditions and almost the same frequency, the length and alignment of the filter cavity with respect to the squeezed vacuum field can be accurately controlled with this scheme. In this paper, we experimentally demonstrate the new control scheme for a filter cavity with coherent control sidebands. In addition to the conventional filter cavity control with the green field, we succeed in controlling the length of a 300-m filter cavity with coherent control sidebands and reduce the filter cavity length noise (rms) from 6.8 to 2.1 pm.

physics.ins-det

A Polarization-Decomposed Method for Simulating Inhomogeneous Birefringence in Laser-Interferometric Gravitational-Wave Detectors

Birefringence in test mass substrates is an emerging limitation for current and future laser-interferometric gravitational-wave detectors, particularly as detectors move toward higher circulating power, cryogenic operation, and crystalline optical materials. Spatially varying birefringence alters both the polarization state and spatial mode content of the intracavity field, reducing interference contrast and coupling into length and alignment control signals. Accurate modeling of these effects is complicated by the fact that most frequency-domain simulation tools employ scalar modal propagation and lack native support for polarization and two-dimensional substrate maps. In this work, we present a practical and general method for simulating inhomogeneous birefringence without modifying existing simulation frameworks. The approach represents the two polarization components as independent scalar fields and introduces their coupling through an equivalent triple-Mach-Zehnder construction that reproduces the Jones matrix of a birefringent medium. We demonstrate the method using realistic birefringence maps of the KAGRA sapphire input test masses. The technique is compatible with any frequency-domain interferometer model and enables efficient birefringence studies for next-generation gravitational-wave detectors.

physics.ins-det

Proof-of-principle demonstration of a Polarization-Circulation Speed Meter

We present the first experimental implementation of a polarization-circulation speed meter. In our experiment, the interferometer was reduced to a single-cavity configuration with all mirrors fixed. A green-locking scheme was employed to stabilize the polarization circulation cavity, and a lock-acquisition procedure was demonstrated to realize speed-meter operation. The system was characterized by measuring the transfer function from a pseudo-displacement signal to the photodetector output, confirming that the device measures the speed of mirror motion. These results support the feasibility of polarization-circulation speed meters and suggest that the control scheme could be extended to more complex configurations, such as Michelson interferometers and suspended-mirror systems.

quant-ph

Jiggled interferometer: Ground-based gravitational wave detector using rapidly-repeated free-falling test masses

We propose the Jiggled Interferometer (JIGI), a novel ground-based gravitational wave detector employing low-frequency noise mitigation similar to that of space-based detectors. Using rapidly-repeated free-fall test masses, JIGI eliminates seismic and suspension thermal noise during free fall. Compared to the Juggled Interferometer, it offers improved angular stability and avoids tracking lasers. We analyze detrending -- a required step to remove actuation-induced noise -- and show sensitivity gains of about four orders of magnitude in the 0.1-0.3 Hz band, relative to seismic and suspension noise extrapolated from the Cosmic Explorer.

gr-qc

Theoretical Characteristics of a three-point Roberts Linkage

The Roberts linkage is recognized for enabling long-period pendulum motion in a compact format. Utilizing this characteristic, we are developing a three-point Roberts linkage for vibration isolation systems, with an eye towards its potential contribution to the development of next-generation interferometric gravitational wave antennas. In this article, we derived the equations to determine the essential parameters when using this linkage as a vibration isolation system, namely the equivalent pendulum length and the relationship between translational motion of the center of mass and rigid body rotation, from size parameters. Additionally, we analyzed the behavior in response to various errors.

physics.ins-det

Optimizing Active Seismic Isolation Systems in Gravitational-Wave Detectors

Gravitational wave detectors such as KAGRA, a 3-km long underground laser interferometer in Japan, require elaborate passive and active seismic isolation of their mirrors. With the aim of detecting passing gravitational waves that create a relative mirror displacement of less than $10^{-22}\ \mathrm{m}$ at frequencies of tens to hundreds of Hz, all environmental couplings must be stringently suppressed. This paper presents the result of applying the H-infinity optimization method to the active seismic isolation of a gravitational-wave detector for the first time. The so-called \textit{sensor correction} and \textit{sensor fusion} schemes of the seismic attenuation system of KAGRA's signal recycling mirror are used as a test bed. We designed and implemented optimal sensor correction and sensor fusion filters, resulting in a sevenfold attenuation of seismic noise coupling to the signal recycling mirror in the 0.1-0.5 Hz band, with the downstream effect of an 88.2% noise performance improvement in the same frequency band. When combined with other hardware upgrades, the implementation of sensor correction and sensor fusion contributed to an increase in KAGRA's duty cycle from 53% in the O3GK observation run to 80% in O4a, demonstrating the effectiveness of the H-infinity optimization approach.

physics.ins-det

Characterisation of birefringence inhomogeneity of KAGRA sapphire mirrors from transmitted wavefront error measurements

Cooling down test masses to cryogenic temperatures is a way to reduce the thermal noise of gravitational wave detectors. Crystalline materials are considered the most promising materials for fabricating cryogenic test masses and their coatings because of their excellent thermal and optical properties at low temperatures. However, birefringence owing to local impurities and inhomogeneities in the crystal can degrade the performance of the detector. The birefringence measurement or mapping over a two-dimensional area is thus important. This study describes a method for fast birefringence measurements of a large sample by simply combining a series of transmission wavefront error measurements using linearly polarised light with Fizeau interferometers. Using this method, the birefringence inhomogeneity information of KAGRA's two input test masses with a diameter of 22 cm was fully reconstructed. The birefringence information was then used to calculate the transverse beam shapes of the light fields in orthogonal polarisation directions when passing through the substrate. It was possible to find a calculated beam shape consistent with in-situ measurements using the KAGRA interferometer. This technique is crucial for birefringence characterisation of test masses in future detectors, where even larger sizes are used.

physics.optics

Control Scheme for Polarization Circulation Speed Meter Using a Dual-Retardation Waveplate

In interferometric gravitational wave detectors, quantum radiation pressure noise, which is a back action of the measurement, will limit their sensitivities at low frequencies. Speed meters are one of the solutions to reduce the back action noise and improve the sensitivities, and furthermore, they can surpass the standard quantum limit over a wide range of frequencies. The Polarization Circulation Speed Meter is the latest incarnation of the speed meter concept in the sense that it requires a slight modification in the conventional interferometer designs; however, its control scheme has not been developed. The main difficulty is the length and alignment control of the cavity formed by the polarization circulation mirror and the input test masses, whose round-trip phase shift should be kept to $\pi$. In this article, we propose a new control scheme using a dual-retardation waveplate, called Dual-Retardance Control (DRC). In addition, we compare the shot noise level of the DRC to another simpler scheme by dithering. Finally, we design the experimental setup for the demonstration of the DRC and show the expected results through the transfer function measurement.

gr-qc

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

physics.ins-det

Cryogenic suspension design for a kilometer-scale gravitational-wave detector

We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while keeping the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for damping control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.

physics.ins-det

Compact integrated optical sensors and electromagnetic actuators for vibration isolation systems in the gravitational-wave detector KAGRA

This paper reports on the design and characteristics of a compact module integrating an optical displacement sensor and an electromagnetic actuator for use with vibration-isolation systems installed in KAGRA, the 3-km baseline gravitational-wave detector in Japan. In technical concept, the module belongs to a family tree of similar modules called OSEMs, used in other interferometric gravitational-wave detector projects. After the initial test run of KAGRA in 2016, the sensor part, which is a type of slot sensor, was modified by increasing the spacing of the slot from 5 mm to 15 mm to avoid the risk of mechanical interference with the sensor flag. We confirm the sensor performance is comparable to that of the previous design despite the modification. We also confirm the sensor noise is consistent with the theoretical noise budget. The noise level is 0.5 nm/rtHz at 1 Hz and 0.1 nm/rtHz at 10 Hz, and the linear range of the sensor is 0.7 mm or more. We measured the response of the actuator to be 1 N/A, and also measured the resistances and inductances of coils of the actuators to confirm consistency with theory. Coupling coefficients among the different degrees of freedom were also measured and shown to be negligible, varying little between designs. A potential concern about thermal noise contribution due to eddy current loss is discussed. As of 2020, 42 of the modules are in operation at the site.

astro-ph.IM

The optical loss study of molecular layer for a cryogenic interferometric gravitational-wave detector

The detection of gravitational-waves provides us with a deep insight into the universe. In order to increase the number of detectable gravitational-wave sources, several future gravitational-wave detectors will operate with cryogenic mirrors. Recent studies, however, showed residual gas molecules inside the vacuum chamber adhere to the cryogenic mirror surface and form a molecular layer which grows with time. The growing molecular layer introduces an additional optical loss in the mirror which can decrease the detector's performance. We theoretically estimate the optical loss by the molecular layer in a cryogenically operated gravitational-wave detector. The impacts on a cryogenic gravitational-wave detector is discussed based on the results of optical loss estimation.

physics.ins-det

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

astro-ph.IM

Estimation of losses in a 300 m filter cavity and quantum noise reduction in the KAGRA gravitational-wave detector

The sensitivity of the gravitational-wave detector KAGRA, presently under construction, will be limited by quantum noise in a large fraction of its spectrum. The most promising technique to increase the detector sensitivity is the injection of squeezed states of light, where the squeezing angle is dynamically rotated by a Fabry-Pérot filter cavity. One of the main issues in the filter cavity design and realization is the optical losses due to the mirror surface imperfections. In this work we present a study of the specifications for the mirrors to be used in a 300 m filter cavity for the KAGRA detector. A prototype of the cavity will be constructed at the National Astronomical Observatory of Japan, inside the infrastructure of the former TAMA interferometer. We also discuss the potential improvement of the KAGRA sensitivity, based on a model of various realistic sources of losses and their influence on the squeezing amplitude.

astro-ph.IM

Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope

KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.

physics.ins-det

Demonstration of displacement sensing of a mg-scale pendulum for mm- and mg- scale gravity measurements

Gravity generated by large masses has been observed using a variety of probes from atomic interferometers to torsional balances. However, gravitational coupling between small masses has never been observed so far. Here, we demonstrate sensitive displacement sensing of the Brownian motion of an optically trapped 7-mg pendulum motion whose natural quality factor is increased to $10^8$ through dissipation dilution. The sensitivity for an integration time of one second corresponds to the displacement generated by the gravitational coupling between the probe and a mm separated 100 mg mass, whose position is modulated at the pendulum mechanical resonant frequency. Development of such a sensitive displacement sensor using a mg-scale device will pave the way for a new class of experiments where gravitational coupling between small masses in quantum regimes can be achieved.

quant-ph

Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectors

Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed vacuum state from the output port of the detector, whit the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important parameters limiting the squeezing performance is represented by the optical losses of the filter cavity. We report here the operation of a 300 m filter cavity prototype installed at the National Astronomical Observatory of Japan (NAOJ). The cavity is designed to obtain a rotation of the squeeze angle below 100 Hz. After achieving the resonance of the cavity with a multi-wavelength technique, the round trip losses have been measured to be between 50 ppm and 90 ppm. This result demonstrates that with realistic assumption on the input squeeze factor and on the other optical losses, a quantum noise reduction of at least 4 dB in the frequency region dominated by radiation pressure can be achieved.

astro-ph.IM

Ground Based Low-Frequency Gravitational-wave Detector With Multiple Outputs

We have developed a new gravitaional-wave (GW) detector, TOrsion-Bar Antenna (TOBA), with multiple-output configuration. TOBA is a detector with bar-shaped test masses that rotate by the tidal force of the GWs. In our detector, three independent information about the GW signals can be derived by monitoring multiple rotational degrees of freedom, i.e., horizontal rotations and vertical rotations of the bars. Since the three outputs have different antenna pattern functions, the multi-output system improves the detection rate and the parameter estimation accuracy. It is effective in order to obtain further details of the GW sources, such as population and directions. We successfully operated the multi-output detector continuously for more than 24 hours with stable data quality. Also, the sensitivity of one of the signals is improved to be $1 \times 10^{-10}$ ${\rm Hz}^{-1/2}$ at 3 Hz by the combination of the passive and active vibration isolation systems, while sensitivities to possible GW signals derived from the vertical rotations are worse than that from the horizontal rotation.

gr-qc