Statistical Image Reconstruction Using Mixed Poisson-Gaussian Noise Model for X-Ray CT

Statistical image reconstruction (SIR) methods for X-ray CT produce high-quality and accurate images, while greatly reducing patient exposure to radiation. When further reducing X-ray dose to an ultra-low level by lowering the tube current, photon starvation happens and electronic noise starts to dominate, which introduces negative or zero values into the raw measurements. These non-positive values pose challenges to post-log SIR methods that require taking the logarithm of the raw data, and causes artifacts in the reconstructed images if simple correction methods are used to process these non-positive raw measurements. The raw data at ultra-low dose deviates significantly from Poisson or shifted Poisson statistics for pre-log data and from Gaussian statistics for post-log data. This paper proposes a novel SIR method called MPG (mixed Poisson-Gaussian). MPG models the raw noisy measurements using a mixed Poisson-Gaussian distribution that accounts for both the quantum noise and electronic noise. MPG is able to directly use the negative and zero values in raw data without any pre-processing. MPG cost function contains a reweighted least square data-fit term, an edge preserving regularization term and a non-negativity constraint term. We use Alternating Direction Method of Multipliers (ADMM) to separate the MPG optimization problem into several sub-problems that are easier to solve. Our results on 3D simulated cone-beam data set and synthetic helical data set generated from clinical data indicate that the proposed MPG method reduces noise and decreases bias in the reconstructed images, comparing with the conventional filtered back projection (FBP), penalized weighted least-square (PWLS) and shift Poisson (SP) method for ultra-low dose CT (ULDCT) imaging.

physics.med-ph↗

Image-domain multi-material decomposition for dual-energy CT based on correlation and sparsity of material images

Dual energy CT (DECT) enhances tissue characterization because it can produce images of basis materials such as soft-tissue and bone. DECT is of great interest in applications to medical imaging, security inspection and nondestructive testing. Theoretically, two materials with different linear attenuation coefficients can be accurately reconstructed using DECT technique. However, the ability to reconstruct three or more basis materials is clinically and industrially important. Under the assumption that there are at most three materials in each pixel, there are a few methods that estimate multiple material images from DECT measurements by enforcing sum-to-one and a box constraint ([0 1]) derived from both the volume and mass conservation assumption. The recently proposed image-domain multi-material decomposition (MMD) method introduces edge-preserving regularization for each material image which neglects the relations among material images, and enforced the assumption that there are at most three materials in each pixel using a time-consuming loop over all possible material-triplet in each iteration of optimizing its cost function. We propose a new image-domain MMD method for DECT that considers the prior information that different material images have common edges and encourages sparsity of material composition in each pixel using regularization.

physics.med-ph↗

Low Dose CT Image Reconstruction With Learned Sparsifying Transform

A major challenge in computed tomography (CT) is to reduce X-ray dose to a low or even ultra-low level while maintaining the high quality of reconstructed images. We propose a new method for CT reconstruction that combines penalized weighted-least squares reconstruction (PWLS) with regularization based on a sparsifying transform (PWLS-ST) learned from a dataset of numerous CT images. We adopt an alternating algorithm to optimize the PWLS-ST cost function that alternates between a CT image update step and a sparse coding step. We adopt a relaxed linearized augmented Lagrangian method with ordered-subsets (relaxed OS-LALM) to accelerate the CT image update step by reducing the number of forward and backward projections. Numerical experiments on the XCAT phantom show that for low dose levels, the proposed PWLS-ST method dramatically improves the quality of reconstructed images compared to PWLS reconstruction with a nonadaptive edge-preserving regularizer (PWLS-EP).

stat.ML↗