SearcharxivSearch

arXiv subjects

Yonghao Gui

Publications and source records attributed to Yonghao Gui.

2 recordsLinked to original sources

Keeping Data Centers Online in Weak Grids: PLL-Free VM-DPC With Adaptive Reactive-Power Support for Centralized UPS Systems

Data center power systems are increasingly exposed to weak-grid conditions due to the rapid growth of converter-dominated networks and highly dynamic artificial intelligence (AI) workloads. In centralized uninterruptible power supply (UPS) architectures, the front-end rectifier continuously processes the incoming facility power, making its dynamic performance critical for ensuring stable operation and reliable power delivery to information technology (IT) equipment. Under weak-grid conditions, conventional phase-locked loop (PLL)-based proportional-integral (PI) rectifier controllers may exhibit instability due to strong interactions between converter control dynamics and grid impedance. This paper investigates the stability of centralized UPS data center systems operating under weak-grid conditions using a detailed switching-level model developed in MATLAB/Simulink and validated in real time using an OPAL-RT platform. To enhance weak-grid stability and improve converter-grid interaction, a voltage-modulated direct power control (VM-DPC) strategy with adaptive reactive power support is applied to the front-end rectifier. The proposed approach directly regulates active and reactive power without PLL synchronization while dynamically supporting the point of common coupling (PCC) voltage during rapid IT load variations. Results demonstrate that conventional PI-based rectifier control becomes unstable under SCR<=2 conditions, leading to dc-link oscillations and degradation of downstream power delivery. In contrast, the proposed VM-DPC strategy restores stable operation, improves system damping, and maintains reliable power transfer to highly dynamic IT loads under weak-grid operation.

eess.SY

Stability Enhancement of Centralized UPS Data Center Systems Under Weak-Grid Conditions

Data center power systems are increasingly exposed to weak-grid conditions due to the evolution of modern power systems and the integration of large and dynamic loads. In centralized uninterruptible power supply (UPS) architectures, the front-end rectifier plays a critical role in maintaining stable operation and ensuring reliable power delivery to information technology (IT) equipment. However, conventional phase-locked loop (PLL)-based proportional-integral (PI) control strategies may exhibit degraded performance or instability under low short-circuit ratio (SCR) conditions. This paper investigates the behavior of centralized UPS systems under weak-grid conditions and demonstrates, through electromagnetic transient simulations, that PI-controlled rectifiers can become unstable at SCR=2. To address this issue, a power-based control approach is applied to the three-phase rectifier, enabling direct regulation of active and reactive power without relying on PLL synchronization. Simulation results show that the proposed control strategy improves system damping and restores stable operation under weak-grid conditions. The findings highlight the importance of control design for maintaining reliable operation of data center power systems in emerging low-strength grid environments.

eess.SY