Searcharxiv⌕ Search

arXiv subjects

Yongjie Zhang

Publications and source records attributed to Yongjie Zhang.

26 records · Page 2Linked to original sources

In-Orbit Instrument Performance Study and Calibration for POLAR Polarization Measurements

POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the Chinese space laboratory TG-2 on 15th September, 2016. In order to reliably reconstruct the polarization information a highly detailed understanding of the instrument is required for both data analysis and Monte Carlo studies. For this purpose a full study of the in-orbit performance was performed in order to obtain the instrument calibration parameters such as noise, pedestal, gain nonlinearity of the electronics, threshold, crosstalk and gain, as well as the effect of temperature on the above parameters. Furthermore the relationship between gain and high voltage of the multi-anode photomultiplier tube has been studied and the errors on all measurement values are presented. Finally the typical systematic error on polarization measurements of Gamma-Ray Bursts due to the measurement error of the calibration parameters are estimated using Monte Carlo simulations.

astro-ph.IM↗

A Low-latency Pipeline for GRB Light Curve and Spectrum using Fermi/GBM Near Real-time Data

Rapid response and short time latency are very important for Time Domain Astronomy, such as the observations of Gamma-ray Bursts (GRBs) and electromagnetic (EM) counterparts of gravitational waves (GWs). Based on the near real-time Fermi/GBM data, we developed a low-latency pipeline to automatically calculate the temporal and spectral properties of GRBs. With this pipeline, some important parameters can be obtained, such as T90 and fluence, within ~20 minutes after the GRB trigger. For ~90% GRBs, T90 and fluence are consistent with the GBM catalog results within 2 sigma errors. This pipeline has been used by the Gamma-ray Bursts Polarimeter (POLAR) and the Insight Hard X-ray Modulation Telescope (Insight-HXMT) to follow up the bursts of interest. For GRB 170817A, the first EM counterpart of GW events detected by Fermi/GBM and INTEGRAL/SPI-ACS, the pipeline gave T90 and spectral information in 21 minutes after the GBM trigger, providing important information for POLAR and Insight-HXMT observations.

astro-ph.IM↗

The Plastic Scintillator Detector at DAMPE

he DArk Matter Particle Explorer (DAMPE) is a general purposed satellite-borne high energy $γ-$ray and cosmic ray detector, and among the scientific objectives of DAMPE are the searches for the origin of cosmic rays and an understanding of Dark Matter particles. As one of the four detectors in DAMPE, the Plastic Scintillator Detector (PSD) plays an important role in the particle charge measurement and the photons/electrons separation. The PSD has 82 modules, each consists of a long organic plastic scintillator bar and two PMTs at both ends for readout, in two layers and covers an overall active area larger than 82 cm $\times$ 82 cm. It can identify the charge states for relativistic ions from H to Fe, and the detector efficiency for Z=1 particles can reach 0.9999. The PSD has been successfully launched with DAMPE on Dec. 17, 2015. In this paper, the design, the assembly, the qualification tests of the PSD and some of the performance measured on the ground have been described in detail.

astro-ph.IM↗

A crosstalk and non-uniformity correction method for the Compact Space-borne Compton Polarimeter POLAR

In spite of extensive observations and numerous theoretical studies in the past decades several key questions related with Gamma-Ray Bursts (GRB) emission mechanisms are still to be answered. Precise detection of the GRB polarization carried out by dedicated instruments can provide new data and be an ultimate tool to unveil their real nature. A novel space-borne Compton polarimeter POLAR onboard the Chinese space station TG2 is designed to measure linear polarization of gamma-rays arriving from GRB prompt emissions. POLAR uses plastics scintillator bars (PS) as gamma-ray detectors and multi-anode photomultipliers (MAPMTs) for readout of the scintillation light. Inherent properties of such detection systems are crosstalk and non-uniformity. The crosstalk smears recorded energy over multiple channels making both non-uniformity corrections and energy calibration more difficult. Rigorous extraction of polarization observable requires to take such effects properly into account. We studied influence of the crosstalk on energy depositions during laboratory measurements with X-ray beams. A relation between genuine and recorded energy was deduced using an introduced model of data analysis. It postulates that both the crosstalk and non-uniformities can be described with a single matrix obtained in calibrations with mono-energetic X- and gamma-rays. Necessary corrections are introduced using matrix based equations allowing for proper evaluation of the measured GRB spectra. Validity of the method was established during dedicated experimental tests. The same approach can be also applied in space utilizing POLAR internal calibration sources. The introduced model is general and with some adjustments well suitable for data analysis from other MAPMT-based instruments.

physics.ins-det↗

Design of a large dynamic range readout unit for the PSD detector of DAMPE

A large dynamic range is required by the Plastic Scintillator Detector (PSD) of DArk Matter Paricle Explorer (DAMPE), and a double-dynode readout has been developed. To verify this design, a prototype detector module has been constructed and tested with cosmic rays and heavy ion beams. The results match with the estimation and the readout unit could easily cover the required dynamic range.

physics.ins-det↗

A versatile PMT test bench and its application in the DAMPE-PSD

A versatile test bench system, dedicated for massive PMT characterization, is developed at the Institute of Modern Physics, Chinese Academy of Sciences. It can perform many test contents with large capacity and high level of automation, and the migration from one testing configuration to another is lightweight and time-saving. This system has been used in the construction of the Plastic Scintillator Detector of DArk Matter Particle Explorer already, and a total of 570 Hamamatsu R4443 tubes have been tested successfully.

physics.ins-det↗

SVOM Gamma Ray Monitor

The Space-based multi-band astronomical Variable Object Monitor (SVOM) mission is dedicated to the detection, localization and broad-band study of Gamma-Ray Bursts (GRBs) and other high-energy transient phenomena. The Gamma Ray Monitor (GRM) onboard is designed to observe the GRBs up to 5 MeV. With this instrument one of the key GRB parameter, Epeak, can be easily measured in the hard x-ray band. It can achieve a detection rate of 100 GRBs per year which ensures the scientific output of SVOM.

astro-ph.IM↗

Light collection of POLAR detector

POLAR is a compact polarimeter dedicated to measure the polarization of GRBs between 50-300 keV. The light collection of 200*6*6mm3 plastic bars has been simulated and optimized in order to get uniform response to x-rays at different points of one single bar. According to the Monte Carlo results, the amplitude uniformity strongly depends on the polishing level of scintillator surface and the covering. A uniformity of 89% is achieved with a prototype constructed by a non position-sensitive PMT and an array of 4X4 bars.

astro-ph.IM↗