SearcharxivSearch

arXiv subjects

Yoomin Oh

Publications and source records attributed to Yoomin Oh.

3 recordsLinked to original sources

New Constraints on Axion-Like Particles with the NEON Detector at a Nuclear Reactor

We report new constraints on axion-like particles (ALPs) using data from the NEON experiment, which features a 16.7 kg of NaI(Tl) target located 23.7 meters from a 2.8 GW thermal power nuclear reactor. Analyzing a total exposure of 3063 kg$\cdot$days, with 1596 kg$\cdot$days during reactor-on and 1467 kg$\cdot$days during reactor-off periods, we compared energy spectra to search for ALP-induced signals. No significant signal was observed, enabling us to set exclusion limits at the 95\% confidence level. These limits probe previously unexplored regions of the ALP parameter space, particularly for axion mass ($m_a$) near $1$ MeV/c$^2$. For ALP-photon coupling (${g_{a\gamma}}$), limits reach as low as 6.24$\times$ 10$^{-6}$ GeV$^{-1}$ at $m_a$ = 3.0 MeV/c$^2$, while for ALP-electron coupling (${g_{ae}}$), limits reach 4.95$\times$ 10$^{-8}$ at $m_a$ = 1.02 MeV/c$^2$. This work demonstrates the potential for future reactor experiments to probe unexplored ALP parameter space.

hep-ex

Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment

A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base solvent of the NEOS detector. Furthermore, a di-isopropylnaphthalene (DIN) is added to improve the light output and pulse shape discrimination (PSD) ability. The ratio of LAB to DIN is 90:10. PPO (3 g/L) and bis-MSB (30 mg/L) are dissolved to formulate the mixture of LAB- and DIN-based liquid scintillator (LS). Then, ~0.5% gadolinium (Gd) is loaded into the LS by using the solvent-solvent extraction technique. In this paper, we report the characteristics of Gd-loaded LS (GdLS) for the NEOS detector and the handling during mass production.

physics.ins-det

NaI (Tl) Calorimeter Calibration and Simulation for Coulomb Sum Rule Experiment in Hall-A at Jefferson Lab

A precision measurment of inclusive electron scattering cross sections was carried out at Jefferson Lab in the quasi-elastic region for ${^4}$He, ${^{12}}$C, ${^{56}}$Fe and ${^{208}}$Pb targets. Longitudinal ($R_{L}$) and transverse ($R_{T}$) response functions of nucleon were extracted in the momentum transfer range 0.55 GeV/c$\le$$|q|$$\le$1.0 GeV/c. To achieve the above goal, a NaI (Tl) calorimeter was used to distinguish good electrons from background including pions and low energy electrons rescattered from walls of the spectrometer magnets. Due to a large set of kinematics and changes in HV settings, a number of calibrations were performed for the NaI (Tl) detector. Corrections for a few blocks of NaI (Tl) with bad or no signal were applied. The resolution of NaI (Tl) detector after calibration reached $\frac{δE}{\sqrt{E}} \approx 3\%$ at E=1 GeV. The performance of NaI (Tl) detector was compared with a simulation.

nucl-ex