SearcharxivSearch

arXiv subjects

Yordanka Dancheva

Publications and source records attributed to Yordanka Dancheva.

18 recordsLinked to original sources

Tri-axial time-dependent magnetic field calibrated in-situ by harmonic analysis of adiabatically evolving atomic spins

We introduce a methodology to calibrate in situ a set of coils generating bi- or tri-axial magnetic fields, at frequencies where a calibration performed under static conditions would be inaccurate. The methodology uses harmonic analysis of one component of the magnetization of an atomic sample whose spins adiabatically follow an ad hoc applied time-dependent field. The procedure enables the identification of phases and amplitudes of the coil currents required to produce a dynamic magnetic field with the assigned polarization. This determines coil constants that can be subsequently used to produce arbitrary three-dimensional time-dependent fields.

physics.ins-det

Spin dynamic response to a time dependent field

The dynamic response of a parametric system constituted by a spin precessing in a time dependent magnetic field is studied by means of a perturbative approach that unveils unexpected features, and is then experimentally validated. The first-order analysis puts in evidence different regimes: beside a tailorable low-pass-filter behaviour, a band-pass response with interesting potential applications emerges. Extending the analysis to the second perturbation order permits to study the response to generically oriented fields and to characterize several non-linear features in the behaviour of such kind of systems.

physics.app-ph

Studying and applying magnetic dressing with a Bell and Bloom magnetometer

The magnetic dressing phenomenon occurs when spins precessing in a static field (holding field) are subject to an additional, strong, alternating field. It is usually studied when such extra field is homogeneous and oscillates in one direction. We study the dynamics of spins under dressing condition in two unusual configurations. In the first instance, an inhomogeneous dressing field produces space dependent dressing phenomenon, which helps to operate the magnetometer in strongly inhomogeneous static field. In the second instance, beside the usual configuration with static and the strong orthogonal oscillating magnetic fields, we add a secondary oscillating field, which is perpendicular to both. The system shows novel and interesting features that are accurately explained and modelled theoretically. Possible applications of these novel features are briefly discussed.

physics.atom-ph

Validation of a fast and accurate magnetic tracker operating in the environmental field

We characterize the performance of a system based on a magnetoresistor array. This instrument is developed to map the magnetic field, and to track a dipolar magnetic source in the presence of a static homogeneous field. The position and orientation of the magnetic source with respect to the sensor frame is retrieved together with the orientation of the frame with respect to the environmental field. A nonlinear best-fit procedure is used, and its precision, time performance, and reliability are analyzed. This analysis is performed in view of the practical application for which the system is designed that is an eye-tracking diagnostics and rehabilitative tool for medical purposes, which require high speed ($\ge 100$~Sa/s) and sub-millimetric spatial resolution. A throughout investigation on the results makes it possible to list several observations, suggestions, and hints, which will be useful in the design of similar setups.

physics.app-ph

Fast, cheap, and scalable magnetic tracker with an array of magnetoresistors

We present the hardware of a cheap multi-sensor magnetometric setup where a relatively large set of magnetic field components is measured in several positions by calibrated magnetoresistive detectors. The setup is developed with the scope of mapping the (inhomogeneous) field generated by a known magnetic source, which is measured as superimposed to the (homogeneous) geomagnetic field. The final goal is to use the data produced by this hardware to reconstruct position and orientation of the magnetic source with respect to the sensor frame, simultaneously with the orientation of the frame with respect to the environmental field. Possible applications of the setup are shortly discussed, together with a synthetic description of the data elaboration and analysis.

physics.ins-det

Ferromagnetic contamination of Ultra-Low-Field-NMR sample containers. Quantification of the problem and possible solutions

The presence of a weak remanence in Ultra-Low-Field (ULF) NMR sample containers is investigated on the basis of proton precession. The high-sensitivity magnetometer used for the NMR detection, enables simultaneously the measurement of the static field produced in the sample proximity by ferromagnetic contaminants. The presence of the latter is studied by high resolution chemical analyses of the surface, based on X-ray fluorescence spectroscopy and secondary ions mass spectroscopy. Methodologies to reduce the contamination are explored and characterized. This study is of relevance in any ULF-NMR experiment, as in the ULF regime spurious ferromagnetism becomes easily a dominant cause of artefacts.

physics.ins-det

Sub-millimetric ultra-low-field MRI detected in situ by a dressed atomic magnetometer

Magnetic Resonance Imaging (MRI) is universally acknowledged as an excellent tool to extract detailed spatial information with minimally invasive measurements. Efforts toward ultra-low-field (ULF) MRI are made to simplify the scanners and to reduce artefacts and incompatibilities. Optical Atomic Magnetometers (OAMs) are among the sensitive magnetic detectors eligible for ULF operation, however they are not compatible with the strong field gradients used in MRI. We show that a magnetic-dressing technique restores the OAMs operability despite the gradient, and we demonstrate sub-millimetric resolution MRI with a compact experimental setup based on an in situ detection. The proof-of-concept experiment produces unidimensional imaging of remotely magnetized samples with a dual sensor, but the approach is suited to be adapted for 3-D imaging of samples magnetized in loco. An extension to multi-sensor architectures is also possible.

physics.app-ph

Spurious Ferromagnetic Remanence Detected by Hybrid Magnetometer

Nuclear magnetic resonance detection in ultra low field regime enables the measurement of different components of a spurious remanence in the polymeric material constituting the sample container. A differential atomic magnetometer detects simultaneously the static field generated by the container and the time-dependent signal from the precessing nuclei. The nuclear precession responds with frequency shifts and decay rate variations to the container magnetization. Two components of the latter act independently on the atomic sensor and on the nuclear sample. A model of the measured signal allows a detailed interpretation, on the basis of the interaction geometry.

physics.ins-det

Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing

We study the possibility of counteracting the line-broadening of atomic magnetic resonances due to inhomogeneities of the static magnetic field by means of spatially dependent magnetic dressing, driven by an alternating field that oscillates much faster than the Larmor precession frequency. We demonstrate that an intrinsic resonance linewidth of 25~Hz that has been broadened up to hundreds Hz by a magnetic field gradient, can be recovered by the application of an appropriate inhomogeneous dressing field. The findings of our experiments may have immediate and important implications, because they facilitate the use of atomic magnetometers as robust, high sensitivity detectors in ultra-low-field NMR imaging.

physics.atom-ph

Self-adaptive loop for external disturbance reduction in differential measurement set-up

We present a method developed to actively compensate common-mode magnetic disturbances on a multi-sensor device devoted to differential measurements. The system uses a field-programmable-gated-array card, and operates in conjunction with a high sensitivity magnetometer: compensating the common-mode of magnetic disturbances results in a relevant reduction of the difference-mode noise. The digital nature of the compensation system allows for using a numerical approach aimed at automatically adapting the feedback loop filter response. A common mode disturbance attenuation exceeding 50 dB is achieved, resulting in a final improvement of the differential noise floor by a factor of 10 over the whole spectral interval of interest.

physics.ins-det

Simultaneous Detection of H and D NMR Signals in a micro-Tesla Field

We present NMR spectra of remote-magnetized deuterated water, detected in an unshielded environment by means of a differential atomic magnetometer. The measurements are performed in a $μ$T field, while pulsed techniques are applied -following the sample displacement- in a 100~$μ$T field, to tip both D and H nuclei by controllable amounts. The broadband nature of the detection system enables simultaneous detection of the two signals and accurate evaluation of their decay times. The outcomes of the experiment demonstrate the potential of ultra-low-field NMR spectroscopy in important applications where the correlation between proton and deuteron spin-spin relaxation rates as a function of external parameters contains significant information.

physics.chem-ph

A low noise modular current source for stable magnetic field control

A low cost, stable, programmable, unipolar current source is described. The circuit is designed in view of a modular arrangement, suitable for applications where several DC sources must be controlled at once. A hybrid switching/linear design helps in improving the stability and in reducing the power dissipation and cross-talking. Multiple units can be supplied by a single DC power supply, while allowing for a variety of maximal current values and compliance voltages at the outputs. The circuit is analogically controlled by an unipolar voltage, enabling current programmability and control through commercial digital-to-analogue conversion cards.

physics.ins-det

Multichannel optical atomic magnetometer operating in unshielded environment

A multi-channel atomic magnetometer operating in an unshielded environment is described and characterised. The magnetometer is based on D1 optical pumping and D2 polarimetry of Cs vapour contained in gas-buffered cells. Several technical implementations are described and discussed in detail. The demonstrated sensitivity of the setup is 100fT/Hz^1/2 when operating in the difference mode.

physics.ins-det

Microtesla NMR J-coupling spectroscopy with an unshielded atomic magnetometer

We present experimental data and theoretical interpretation of NMR spectra of remotely magnetized samples, detected in an unshielded environment by means of a differential atomic magnetometer. The measurements are performed in an ultra-low-field at an intermediate regime, where the J-coupling and the Zeeman energies have comparable values and produce rather complex line sets, which are satisfactorily interpreted.

physics.chem-ph

A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free induction decay in ultra-low-field and zero-field NMR experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a 'cold' environment.

physics.ins-det

Stray Magnetic Field Compensation with a Scalar Atomic Magnetometer

We describe a system for the compensation of time-dependent stray magnetic fields using a dual channel scalar magnetometer based on non-linear Faraday rotation in synchronously optically pumped Cs vapour. We detail the active control strategy, with an emphasis on the electronic circuitry, based on a simple phase-locked-loop integrated circuit. The performance and limits of the system developed are tested and discussed. The system was applied to significantly improve the detection of free induction decay signals from protons of remotely magnetized water precessing in an ultra-low magnetic field.

physics.ins-det

All-optical magnetometry for NMR detection in a micro-Tesla field and unshielded environment

An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 $μT$ field. Nuclear spins are manipulated either by $π/2$ pulses or by non-adiabatic rotation. The magnetometer operates at room temperature, in an unshielded environment and has a dual-channel sensor for differential measurements.

physics.atom-ph