Searcharxiv⌕ Search

arXiv subjects

Youngjun Cho

Publications and source records attributed to Youngjun Cho.

28 records · Page 2Linked to original sources

Physiological and Affective Computing through Thermal Imaging: A Survey

Thermal imaging-based physiological and affective computing is an emerging research area enabling technologies to monitor our bodily functions and understand psychological and affective needs in a contactless manner. However, up to recently, research has been mainly carried out in very controlled lab settings. As small size and even low-cost versions of thermal video cameras have started to appear on the market, mobile thermal imaging is opening its door to ubiquitous and real-world applications. Here we review the literature on the use of thermal imaging to track changes in physiological cues relevant to affective computing and the technological requirements set so far. In doing so, we aim to establish computational and methodological pipelines from thermal images of the human skin to affective states and outline the research opportunities and challenges to be tackled to make ubiquitous real-life thermal imaging-based affect monitoring a possibility.

cs.HC↗

Nose Heat: Exploring Stress-induced Nasal Thermal Variability through Mobile Thermal Imaging

Automatically monitoring and quantifying stress-induced thermal dynamic information in real-world settings is an extremely important but challenging problem. In this paper, we explore whether we can use mobile thermal imaging to measure the rich physiological cues of mental stress that can be deduced from a person's nose temperature. To answer this question we build i) a framework for monitoring nasal thermal variable patterns continuously and ii) a novel set of thermal variability metrics to capture a richness of the dynamic information. We evaluated our approach in a series of studies including laboratory-based psychosocial stress-induction tasks and real-world factory settings. We demonstrate our approach has the potential for assessing stress responses beyond controlled laboratory settings.

cs.HC↗

Expressive haptics for enhanced usability of mobile interfaces in situations of impairments

Designing for situational awareness could lead to better solutions for disabled people, likewise, exploring the needs of disabled people could lead to innovations that can address situational impairments. This in turn can create non-stigmatising assistive technology for disabled people from which eventually everyone could benefit. In this paper, we investigate the potential for advanced haptics to compliment the graphical user interface of mobile devices, thereby enhancing user experiences of all people in some situations (e.g. sunlight interfering with interaction) and visually impaired people. We explore technical solutions to this problem space and demonstrate our justification for a focus on the creation of kinaesthetic force feedback. We propose initial design concepts and studies, with a view to co-create delightful and expressive haptic interactions with potential users motivated by scenarios of situational and permanent impairments.

cs.HC↗

Instant Automated Inference of Perceived Mental Stress through Smartphone PPG and Thermal Imaging

Background: A smartphone is a promising tool for daily cardiovascular measurement and mental stress monitoring. A smartphone camera-based PhotoPlethysmoGraphy (PPG) and a low-cost thermal camera can be used to create cheap, convenient and mobile monitoring systems. However, to ensure reliable monitoring results, a person has to remain still for several minutes while a measurement is being taken. This is very cumbersome and makes its use in real-life mobile situations quite impractical. Objective: We propose a system which combines PPG and thermography with the aim of improving cardiovascular signal quality and capturing stress responses quickly. Methods: Using a smartphone camera with a low cost thermal camera added on, we built a novel system which continuously and reliably measures two different types of cardiovascular events: i) blood volume pulse and ii) vasoconstriction/dilation-induced temperature changes of the nose tip. 17 healthy participants, involved in a series of stress-inducing mental workload tasks, measured their physiological responses to stressors over a short window of time (20 seconds) immediately after each task. Participants reported their level of perceived mental stress using a 10-cm Visual Analogue Scale (VAS). We used normalized K-means clustering to reduce interpersonal differences in the self-reported ratings. For the instant stress inference task, we built novel low-level feature sets representing variability of cardiovascular patterns. We then used the automatic feature learning capability of artificial Neural Networks (NN) to improve the mapping between the extracted set of features and the self-reported ratings. We compared our proposed method with existing hand-engineered features-based machine learning methods. Results, Conclusions: ... due to limited space here, we refer to our manuscript.

physics.med-ph↗

Sensorless Resonance Tracking of Resonant Electromagnetic Actuator through Back-EMF Estimation for Mobile Devices

Resonant electromagnetic actuators have been broadly used as vibration motors for mobile devices given their ability of generating relatively fast, strong, and controllable vibration force at a given resonant frequency. Mechanism of the actuators that is based on mechanical resonance, however, limits their use to a situation where their resonant frequencies are known and unshifted. In reality, there are many factors that alter the resonant frequency: for example, manufacturing tolerances, worn mechanical components such as a spring, nonlinearity in association with different input voltage levels. Here, we describe a sensorless resonance tracking method that actuates the motor and automatically detects its unknown damped natural frequency through the estimation of back electromotive force (EMF) and inner mass movements. We demonstrate the tracking performance of the proposed method through a series of experiments. This approach has the potential to control residual vibrations and then improve vibrotactile feedback, which can potentially be used for human-computer interaction, cognitive and affective neuroscience research.

physics.app-ph↗

RealPen: Providing Realism in Handwriting Tasks on Touch Surfaces using Auditory-Tactile Feedback

We present RealPen, an augmented stylus for capacitive tablet screens that recreates the physical sensation of writing on paper with a pencil, ball-point pen or marker pen. The aim is to create a more engaging experience when writing on touch surfaces, such as screens of tablet computers. This is achieved by re-generating the friction-induced oscillation and sound of a real writing tool in contact with paper. To generate realistic tactile feedback, our algorithm analyses the frequency spectrum of the friction oscillation generated when writing with traditional tools, extracts principal frequencies, and uses the actuator's frequency response profile for an adjustment weighting function. We enhance the realism by providing the sound feedback aligned with the writing pressure and speed. Furthermore, we investigated the effects of superposition and fluctuation of several frequencies on human tactile perception, evaluated the performance of RealPen, and characterized users' perception and preference of each feedback type.

cs.HC↗

Deep Thermal Imaging: Proximate Material Type Recognition in the Wild through Deep Learning of Spatial Surface Temperature Patterns

We introduce Deep Thermal Imaging, a new approach for close-range automatic recognition of materials to enhance the understanding of people and ubiquitous technologies of their proximal environment. Our approach uses a low-cost mobile thermal camera integrated into a smartphone to capture thermal textures. A deep neural network classifies these textures into material types. This approach works effectively without the need for ambient light sources or direct contact with materials. Furthermore, the use of a deep learning network removes the need to handcraft the set of features for different materials. We evaluated the performance of the system by training it to recognise 32 material types in both indoor and outdoor environments. Our approach produced recognition accuracies above 98% in 14,860 images of 15 indoor materials and above 89% in 26,584 images of 17 outdoor materials. We conclude by discussing its potentials for real-time use in HCI applications and future directions.

cs.CV↗

ThermSense: Smartphone-based Breathing Sensing Platform using Noncontact Low-Cost Thermal Camera

The ability of sensing breathing is becoming an increasingly important function for technology that aims at supporting both psychological and physical wellbeing. We demonstrate ThermSense, a new breathing sensing platform based on smartphone technology and low-cost thermal camera, which allows a user to measure his/her breathing pattern in a contact-free manner. With the designed key functions of Thermal Voxel Integration-based breathing estimation and respiration variability spectrogram (RVS, bi-dimensional representation of breathing dynamics), the developed platform provides scalability and flexibility for gathering respiratory physiological measurements ubiquitously. The functionality could be used for a variety of applications from stress monitoring to respiration training.

cs.HC↗

Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging

The ability to monitor respiratory rate is extremely important for medical treatment, healthcare and fitness sectors. In many situations, mobile methods, which allow users to undertake every day activities, are required. However, current monitoring systems can be obtrusive, requiring users to wear respiration belts or nasal probes. Recent advances in thermographic systems have shrunk their size, weight and cost, to the point where it is possible to create smart-phone based respiration rate monitoring devices that are not affected by lighting conditions. However, mobile thermal imaging is challenged in scenes with high thermal dynamic ranges. This challenge is further amplified by general problems such as motion artifacts and low spatial resolution, leading to unreliable breathing signals. In this paper, we propose a novel and robust approach for respiration tracking which compensates for the negative effects of variations in the ambient temperature and motion artifacts and can accurately extract breathing rates in highly dynamic thermal scenes. It has three main contributions. The first is a novel Optimal Quantization technique which adaptively constructs a color mapping of absolute temperature to improve segmentation, classification and tracking. The second is the Thermal Gradient Flow method that computes thermal gradient magnitude maps to enhance accuracy of the nostril region tracking. Finally, we introduce the Thermal Voxel method to increase the reliability of the captured respiration signals compared to the traditional averaging method. We demonstrate the extreme robustness of our system to track the nostril-region and measure the respiratory rate in high dynamic range scenes.

cs.CV↗

DeepBreath: Deep Learning of Breathing Patterns for Automatic Stress Recognition using Low-Cost Thermal Imaging in Unconstrained Settings

We propose DeepBreath, a deep learning model which automatically recognises people's psychological stress level (mental overload) from their breathing patterns. Using a low cost thermal camera, we track a person's breathing patterns as temperature changes around his/her nostril. The paper's technical contribution is threefold. First of all, instead of creating hand-crafted features to capture aspects of the breathing patterns, we transform the uni-dimensional breathing signals into two dimensional respiration variability spectrogram (RVS) sequences. The spectrograms easily capture the complexity of the breathing dynamics. Second, a spatial pattern analysis based on a deep Convolutional Neural Network (CNN) is directly applied to the spectrogram sequences without the need of hand-crafting features. Finally, a data augmentation technique, inspired from solutions for over-fitting problems in deep learning, is applied to allow the CNN to learn with a small-scale dataset from short-term measurements (e.g., up to a few hours). The model is trained and tested with data collected from people exposed to two types of cognitive tasks (Stroop Colour Word Test, Mental Computation test) with sessions of different difficulty levels. Using normalised self-report as ground truth, the CNN reaches 84.59% accuracy in discriminating between two levels of stress and 56.52% in discriminating between three levels. In addition, the CNN outperformed powerful shallow learning methods based on a single layer neural network. Finally, the dataset of labelled thermal images will be open to the community.

cs.HC↗