SearcharxivSearch

arXiv subjects

Yu-Guang Xie

Publications and source records attributed to Yu-Guang Xie.

3 recordsLinked to original sources

Performance of the Gamma-ray Transient Monitor at the IHEP Electron-Beam Facility

Gamma-Ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite, with the scientific objective of detecting gamma-ray bursts in the energy range of 20 keV to 1 MeV. GTM is equipped with five Gamma-Ray Transient Probes (GTPs), utilizing NaI(Tl) scintillators coupled with silicon photomultiplier (SiPM) arrays for signal readout. To test the performance of the GTP in detecting electrons, we used the IHEP Electron-Beam Facility (a continuous-energy-tunable, low-current, quasi-single-electron accelerator) for ground-based electron tests of the GTP. This paper provides a detailed description of the operating principles of the electron accelerator and presents the process and results of the GTP electron-beam tests. The test results show that the GTP has a dead time of less than 4 $μ$s for normal signals and approximately 70 $μ$s for overflow signals, consistent with the design specifications. The time-recording capability of the GTP was tested and found to be normal, with accurate recording of overflow events. The GTP's response to electrons in the 0.4-1.4 MeV range is also normal. Additionally, we used Geant4 to simulate the GTP's energy response and performed a comparative analysis of the simulation and experimental results. The performance tests and ground-based electron calibration validated the design of the GTP and enhanced the GTP's mass model, laying the foundation for payload development, in-orbit observation strategies, and scientific data analysis.

astro-ph.IM

Simulation and performance study of the ceramic THGEM

The THGEMs based on ceramic substrate were developed successfully for neutron and single photon detection. The influences on thermal neutron scattering and the internal radioactivity of both ceramic and FR-4 substrates were studied and compared. The ceramic THGEMs are homemade of 200 um hole diameter, 600 um pitch, 200 um thickness, 80 um rim, and 50 mm*50 mm sensitive area. The FR-4 THGEMs with the same geometry were used for the reference. The gas gain, energy resolution and gain stability were measured in different gas mixtures by using the 5.9 keV X-rays. The maximum gain of single layer ceramic THGEM reaches 6*104 and 1.5*104 at Ne+CH4 = 95:5 and Ar+i-C4H10 = 97:3, respectively. The energy resolution is better than 24%. The good gain stability was obtained during more than 100 hour continuous test at Ar+CO2 = 80:20. By using the 239Pu source, the alpha deposited energy spectrum and gain curve of ceramic THGEM were measured.

physics.ins-det

Experimental study of THGEM detector with mini-rim

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10μm) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double THGEM respectively, while the energy resolution of 5.9 keV X-ray varied from 18% to 28% for both single and double THGEM detectors of different hole sizes and thicknesses.All the experiments were investigated in mixture of noble gases(argon,neon) and small content of other gases(iso-butane,methane) at atmospheric pressure.

physics.ins-det