SearcharxivSearch

arXiv subjects

Yu-Hong Yu

Publications and source records attributed to Yu-Hong Yu.

4 recordsLinked to original sources

Comparison of proton shower developments in the BGO calorimeter of the Dark Matter Particle Explorer between GEANT4 and FLUKA simulations

The DArk Matter Particle Explorer (DAMPE) is a satellite-borne detector for high-energy cosmic rays and $\gamma$-rays. To fully understand the detector performance and obtain reliable physical results, extensive simulations of the detector are necessary. The simulations are particularly important for the data analysis of cosmic ray nuclei, which relies closely on the hadronic and nuclear interactions of particles in the detector material. Widely adopted simulation softwares include the GEANT4 and FLUKA, both of which have been implemented for the DAMPE simulation tool. Here we describe the simulation tool of DAMPE and compare the results of proton shower properties in the calorimeter from the two simulation softwares. Such a comparison gives an estimate of the most significant uncertainties of our proton spectral analysis.

physics.ins-det

Calibration of the DAMPE Plastic Scintillator Detector and its on-orbit performance

DArk Matter Particle Explorer (DAMPE) is a space-borne apparatus for detecting the high-energy cosmic-rays like electrons, $\gamma$-rays, protons and heavy-ions. Plastic Scintillator Detector (PSD) is the top-most sub-detector of the DAMPE. The PSD is designed to measure the charge of incident high-energy particles and it also serves as a veto detector for discriminating $\gamma$-rays from charged particles. In this paper, PSD on-orbit calibration procedure is described, which includes five steps of pedestal, dynode correlation, response to minimum-ionizing particles (MIPs), light attenuation function and energy reconstruction. A method for reconstructing the charge of incident high energy cosmic-ray particles is introduced. The detection efficiency of each PSD strip is verified to be above 99.5%, the total efficiency of the PSD for charged particles is above 99.99%.

astro-ph.IM

A Method of Alignment of the Plastic Scintillator Detector of DAMPE

The Plastic Scintillator Detector (PSD) of the DArk Matter Particle Explorer (DAMPE) is designed to measure cosmic ray charge (Z) and to act as a veto detector for gamma-ray identification. In order to fully exploit the charge identification potential of the PSD and to enhance its capability to identify the gamma ray events, we develop a PSD detector alignment method. The path length of a given track in the volume of a PSD bar is derived taking into account the shift and rotation alignment corrections. By examining energy spectra of corner-passing events and fully contained events, position shifts and rotations of all PSD bars are obtained, and found to be on average about 1mm and 0.0015 radian respectively. To validate the alignment method, we introduce the artificial shifts and rotations of PSD bars in the detector simulation. These shift and rotation parameters can be recovered successfully by the alignment procedure. As a result of the PSD alignment procedure, the charge resolution of the PSD is improved from $4\%$ to $8\%$ depending on the nuclei.

astro-ph.IM

Temperature dependence of the plastic scintillator detector for DAMPE

The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -$10$ to $30^{\circ}$C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintillator bar, the photomultiplier tube (PMT), and the Front End Electronics (FEE). These three parts have been studied in detail and the contribution of each part has been obtained and discussed. The temperature coefficient of the PMT is $-0.320(\pm0.033)\%/^{\circ}$C, and the coefficient of the plastic scintillator bar is $-0.036(\pm0.038)\%/^{\circ}$C. This result means that after subtracting the FEE pedestal, the variation of the signal amplitude of the PMT-scintillator system due to temperature mainly comes from the PMT, and the plastic scintillator bar is not sensitive to temperature over the operating range. Since the temperature effect cannot be ignored, the temperature dependence of the whole PSD has been also studied and a correction has been made to minimize this effect. The correction result shows that the effect of temperature on the signal amplitude of the PSD system can be suppressed.

physics.ins-det