SearcharxivSearch

arXiv subjects

Yu-Sa Wang

Publications and source records attributed to Yu-Sa Wang.

6 recordsLinked to original sources

The In-Flight Realtime Trigger and Localization Software of GECAM

Realtime trigger and localization of bursts are the key functions of GECAM, which is an all-sky gamma-ray monitor launched in Dec 10, 2020. We developed a multifunctional trigger and localization software operating on the CPU of the GECAM electronic box (EBOX). This onboard software has the following features: high trigger efficiency for real celestial bursts with a suppression of false triggers caused by charged particle bursts and background fluctuation, dedicated localization algorithm optimized for short and long bursts respetively, short time latency of the trigger information which is downlinked throught the BeiDou satellite navigation System (BDS). This paper presents the detailed design and deveopment of this trigger and localization software system of GECAM, including the main functions, general design, workflow and algorithms, as well as the verification and demonstration of this software, including the on-ground trigger tests with simulated gamma-ray bursts made by a dedicated X-ray tube and the in-flight performance to real gamma-ray bursts and magnetar bursts.

astro-ph.IM

Discovery of oscillations above 200 keV in a black hole X-ray binary with Insight-HXMT

Low-frequency quasi-periodic oscillations (LFQPOs) are commonly found in black hole X-ray binaries, and their origin is still under debate. The properties of LFQPOs at high energies (above 30 keV) are closely related to the nature of the accretion flow in the innermost regions, and thus play a crucial role in critically testing various theoretical models. The Hard X-ray Modulation Telescope (Insight-HXMT) is capable of detecting emissions above 30 keV, and is therefore an ideal instrument to do so. Here we report the discovery of LFQPOs above 200 keV in the new black hole MAXI J1820+070 in the X-ray hard state, which allows us to understand the behaviours of LFQPOs at hundreds of kiloelectronvolts. The phase lag of the LFQPO is constant around zero below 30 keV, and becomes a soft lag (that is, the high-energy photons arrive first) above 30 keV. The soft lag gradually increases with energy and reaches ~0.9s in the 150-200 keV band. The detection at energies above 200 keV, the large soft lag and the energy-related behaviors of the LFQPO pose a great challenge for most currently existing models, but suggest that the LFQPO probably originates from the precession of a small-scale jet.

astro-ph.HE

The influence of the Insight-HXMT/LE time response on timing analysis

LE is the low energy telescope of Insight-HXMT. It uses swept charge devices (SCDs) to detect soft X-ray photons. The time response of LE is caused by the structure of SCDs. With theoretical analysis and Monte Carlo simulations we discuss the influence of LE time response (LTR) on the timing analysis from three aspects: the power spectral density, the pulse profile and the time lag. After the LTR, the value of power spectral density monotonously decreases with the increasing frequency. The power spectral density of a sinusoidal signal reduces by a half at frequency 536 Hz. The corresponding frequency for QPO signals is 458 Hz. The Root mean square (RMS) of QPOs holds the similar behaviour. After the LTR, the centroid frequency and full width at half maxima (FWHM) of QPOs signals do not change. The LTR reduces the RMS of pulse profiles and shifts the pulse phase. In the time domain, the LTR only reduces the peak value of the crosscorrelation function while it does not change the peak position. Thus it will not affect the result of the time lag. When considering the time lag obtained from two instruments and one among them is LE, a 1.18 ms lag is expected caused by the LTR. The time lag calculated in the frequency domain is the same as that in the time domain.

astro-ph.IM

Studies on the time response distribution of Insigh}-HXMT/LE

The Hard X-ray Modulation Telescope (HXMT) named Insight is China's first X-ray astronomical satellite. The Low Energy X-ray Telescope (LE) is one of its main payloads onboard. The detectors of LE adopt swept charge device CCD236 with L-shaped transfer electrodes. Charges in detection area are read out continuously along specific paths, which leads to a time response distribution of photons readout time. We designed a long exposure readout mode to measure the time response distribution. In this mode, CCD236 firstly performs exposure without readout, then all charges generated in preceding exposure phase are read out completely. Through analysis of the photons readout time in this mode, we obtained the probability distribution of photons readout time.

astro-ph.IM

A digital CDS technique and the performance testing

Readout noise is a critical parameter for characterizing the performance of charge-coupled devices (CCDs), which can be greatly reduced by the correlated double sampling (CDS) circuit. However, conventional CDS circuit inevitably introduces new noises since it consists of several active analog components such as operational amplifiers. This paper proposes a digital CDS circuit technique, which transforms the pre-amplified CCD signal into a train of digital presentations by a high-speed data acquisition card directly without the noisy CDS circuit first, then implement the digital CDS algorithm through numerical method. The readout noise of 3.3 e$^{-}$ and the energy resolution of 121 eV@5.9keV can be achieved via the digital CDS technique.

physics.ins-det

Proton irradiation effect on SCDs

The Low Energy X-ray Telescope is a main payload on the Hard X-ray Modulation Telescope satellite. The swept charge device is selected for the Low Energy X-ray Telescope. As swept charge devices are sensitive to proton irradiation, irradiation test was carried out on the HI-13 accelerator at the China Institute of Atomic Energy. The beam energy was measured to be 10 MeV at the SCD. The proton fluence delivered to the SCD was $3\times10^{8}\mathrm{protons}/\mathrm{cm}^{2}$ over two hours. It is concluded that the proton irradiation affects both the dark current and the charge transfer inefficiency of the SCD through comparing the performance both before and after the irradiation. The energy resolution of the proton-irradiated SCD is 212 eV@5.9 keV at $-60\,^{\circ}\mathrm{C}$, while it before irradiated is 134 eV. Moreover, better performance can be reached by lowering the operating temperature of the SCD on orbit.

physics.ins-det