Searcharxiv⌕ Search

arXiv subjects

Yubo Guo

Publications and source records attributed to Yubo Guo.

2 recordsLinked to original sources

WorldBridge: Bridging Video and Action for Task Generalization in World Action Models

Achieving the broad task generalization of embodied models in physical environments remains a central challenge in robot learning. We study this challenge in World Action Models (WAMs) through two complementary capabilities: video generalization, which predicts the visual evolution of new tasks, and action generalization, which translates these predictions into executable behavior through a video-to-action bridge. By varying video and action supervision for tasks outside an initial training set, we examine their respective contributions to task transfer. On RoboTwin 2.0, using only in-distribution video-action supervision yields a 25.07% success rate on out-of-distribution tasks. Introducing videos of these tasks without their action labels raises success to 55.90%, while adding just one action-labeled demonstration per task further improves it to 70.70%. These findings suggest that broader video coverage enables task transfer by leveraging existing inverse-dynamics capabilities, while even sparse action supervision further strengthens those capabilities. Guided by this perspective, we introduce WorldBridge, a WAM with separate video and action experts connected through structured attention and trained with joint flow matching. WorldBridge incorporates visual memory at two temporal scales and action forcing, alongside a unified data processing pipeline that standardizes and filters heterogeneous robot trajectories and egocentric hand-derived supervision. Across multiple manipulation benchmarks, WorldBridge achieves state-of-the-art performance among the compared methods, including 96.23% on RoboTwin 2.0 full data setting and 80.9% on clean to random setting, 82.8% on RoboCasa GR1 TableTop, and 57.6% on DOMINO Level-1. Our study highlights the complementary roles of video prediction and action grounding in developing robots that generalize across tasks.

cs.RO↗

Accurate myocardial T1 mapping at 5T using an improved MOLLI method: A validation study

Background: Accurate myocardial T1 mapping at 5T remains a technical challenge due to field inhomogeneity and prolonged T1 values. The aim of this study is to develop an accurate and clinically applicable myocardial T1 mapping technique for 5T magnetic resonance imaging (MRI) systems and validate its performance in a multicenter study. Methods: The proposed method is based on a 5-(3)-3 MOLLI sequence, dubbed combined-correction MOLLI (coMOLLI), which corrects for both inversion efficiency and readout-induced signal disturbances. Specifically, coMOLLI employs a gradient recalled echo (GRE) readout rather than the commonly used bSSFP readout. Its signal evolution is modeled to estimate T1 values, which incorporates both inversion efficiency and readout disturbances to improve fitting accuracy. To further enhance accuracy, the inversion pulse was redesigned under hardware constraints and the observed B0 and B1 variations over the heart at 5T, using adiabatic hyperbolic secant (HSn) and tangent/hyperbolic tangent (Tan/Tanh) pulses. The method was validated in phantom experiments, as well as in 21 healthy volunteers and 9 patients. Results: The optimized inversion pulse at 5T is the Tan/Tanh pulse with A = 10 kHz, K_s = 4, k = 22, and T_p = 8 ms. In phantom studies, coMOLLI showed high accuracy versus reference IR-FSE, yielding relative errors within 5% for all nine vials. In vivo studies, the average native myocardial T1 values across 21 healthy volunteers were 1468 +/- 48 ms, 1514 +/- 39 ms, and 1545 +/- 50 ms, and blood T1 values were 2182 +/- 132 ms, 2124 +/- 153 ms, and 2131 +/- 158 ms for apical, middle, and base slices, respectively. Conclusion: The coMOLLI method demonstrated high accuracy in phantom studies and feasibility in vivo studies. By adopting the widely used 5-(3)-3 MOLLI acquisition scheme, it shows potential for clinical cardiac imaging at 5T.

physics.med-ph↗