SearcharxivSearch

arXiv subjects

Yuemei Peng

Publications and source records attributed to Yuemei Peng.

3 recordsLinked to original sources

Booster-based beam recycling for swap-out injection at the High Energy Photon Source

Fourth-generation synchrotron light sources employ ultralow-emittance storage rings with stringent injection requirements. On-axis swap-out injection alleviates the dependence on storage-ring dynamic aperture, but high-charge operation requires an efficient injector architecture capable of producing high-charge replacement bunches. This paper presents the accelerator physics design and performance analysis of a booster-based beam-recycling swap-out injection scheme implemented at the High Energy Photon Source (HEPS). In this approach, the full-energy booster serves as both an injector and a high-energy accumulator. An extracted storage-ring bunch is returned to the booster, merged with a low-charge bunch previously injected from the linac and accelerated to full energy. Following high-energy damping, the merged bunch is reinjected into the original storage-ring bucket. The scheme avoids the need for a dedicated accumulator ring while enabling high-charge bunch replacement. The recycling scheme was commissioned through staged machine studies. Full recycling-chain simulations, commissioning studies, and measured performance analysis are presented. The measured results characterize the recycling operation and quantify the transmission efficiency and performance limitations of the complete recycling loop. These results demonstrate the feasibility of the booster-based beam-recycling architecture and establish its operational basis for high-charge swap-out injection in future fourth-generation synchrotron light sources.

physics.acc-ph

Development of high-level applications for High Energy Photon Source booster

The High Energy Photon Source (HEPS), is the first fourth-generation storage ring light source being built in the suburb of Beijing, China. The storage ring was designed with the emittance lower than 60 pm.rad with a circumference of 1.36 km and beam energy of 6 GeV. Its injector contains a 500 MeV S-band Linac and a 454 m booster which was designed as an accumulator at the extraction energy. In the energy ramping control design of HEPS booster, the ramping process was programed to be able to stop and stay at any energy between the injection energy and the extraction energy. This feature enables us to conduct energy-dependent machine studies and ramping curve optimization. The beam commissioning of HEPS Linac finished in June, 2023. And the beam commissioning of booster started in the end of July, 2023. In November 17, main target values proposed in the preliminary design report has been reached. The high-level applications (HLAs) are essential tools for beam commissioning. The development of HLAs, which are based on the framework named Python accelerator physics application set (Pyapas), started in the end of 2021. The HEPS physics team spent more than one year to develop and test the HLAs to meet the requirements of beam commissioning of the booster. Thanks to the modular design, the principle based on physical quantities, and the ability of running simulation models online from the Pyapas, the development efficiency and reliability of the HLAs have been greatly improved. In particular, the principle based on physical quantities allows us to control the beam more intuitively.

physics.acc-ph

Concept for a Future Super Proton-Proton Collider

Following the discovery of the Higgs boson at LHC, new large colliders are being studied by the international high-energy community to explore Higgs physics in detail and new physics beyond the Standard Model. In China, a two-stage circular collider project CEPC-SPPC is proposed, with the first stage CEPC (Circular Electron Positron Collier, a so-called Higgs factory) focused on Higgs physics, and the second stage SPPC (Super Proton-Proton Collider) focused on new physics beyond the Standard Model. This paper discusses this second stage.

physics.acc-ph