SearcharxivSearch

arXiv subjects

Yueping Liu

Publications and source records attributed to Yueping Liu.

5 recordsLinked to original sources

A Clinically Validated Foundation Model for Comprehensive Lung Pathology Interpretation

Pathological assessment guides lung cancer diagnosis, treatment selection, and prognostic evaluation, yet current CPath approaches rely on task-specific models for isolated objectives. Although pan-cancer foundation models offer versatility, they lack subspecialty-level depth and have not been evaluated across clinical workflows or prospectively validated in real-world settings. We introduce PulmoFoundation, a multi-center, prospectively validated, randomized controlled trial (RCT)-evaluated foundation model for comprehensive lung pathology assessment across pre-operative, intra-operative, and post-operative care. Built upon Virchow2 via subspecialty-specific pretraining using ~40,000 diagnostic H&E-stained whole-slide images (WSIs), PulmoFoundation was systematically evaluated on ~26,000 WSIs across 32 clinically relevant tasks. In addition to accurately predicting molecular markers and patient survival, our model achieves clinical-grade performance in core diagnostic tasks across biopsy, frozen section, and surgical resection slides. In a registered prospective study of 1,357 patients across 11 diagnostic tasks, our model achieved an average AUC of 92.3%. Using pre-specified triage thresholds, PulmoFoundation could reduce additional second-review burden for 68.8% of biopsies and 83.0% of frozen sections, and defer 44.5% of IHC stain orders, with PPVs of 1.000, 0.991, and 0.966. Beyond prospective validation, we conducted a crossover RCT with eight pathologists, in which AI assistance improved diagnostic accuracy across 5,264 case-reader pairs (91.7% w/ AI vs. 83.2% w/o AI). AI assistance also reduced median diagnostic time by 18.3%, increased diagnostic confidence by 9.0%, and improved inter-rater agreement from moderate (kappa = 0.55) to substantial (kappa = 0.76). Together, these evaluations support PulmoFoundation as a clinically validated decision-support system for lung pathology.

eess.IV

A Deployment-Friendly Foundational Framework for Efficient Computational Pathology

Pathology foundation models (PFMs) generalize well across computational pathology tasks but remain costly for gigapixel whole-slide image analysis. Here, we present LitePath, a deployment-friendly framework that addresses model over-parameterization and patch-level redundancy. LitePath combines LiteFM, a compact model distilled from Virchow2, H-Optimus-1 and UNI2 using 190 million patches, with the Adaptive Patch Selector for task-specific patch selection. Compared with Virchow2, LitePath uses 28x fewer parameters and 403.5x fewer FLOPs. On an NVIDIA Jetson Orin Nano Super, it processes 208 slides per hour, 104.5x faster than Virchow2, and consumes 0.36 kWh per 3,000 slides, 171x less energy than Virchow2 on an RTX 3090 GPU. We evaluated LitePath on 45 multicenter cohorts across four organs and 33 tasks, comprising 37 classification and 8 survival cohorts, including 33 internal, 10 external and 2 prospective cohorts, with 17,837 slides from 9,977 patients disjoint from the pretraining data. Among 22 PFMs, LitePath achieved the best average rank (6.56 vs. 6.58 for Virchow2), retained 99.71% of Virchow2's Macro-AUC across classification cohorts, and improved mean C-index by 2.14 percentage points across survival cohorts (71.91% vs. 69.77%). We further introduce the Deployability Score (D-Score), a weighted geometric mean of normalized task performance and FLOPs. LitePath achieved the highest D-Score (0.8455), outperforming H0-mini (0.7723) and Virchow2 (0.7297). In a randomized paired crossover study of four pathologists and 120 cases, LitePath increased diagnostic accuracy by 4.1-15.8 percentage points and reduced diagnostic time by 10.9-14.2%. These results demonstrate rapid, cost-effective and energy-efficient pathology image analysis on accessible hardware while maintaining competitive performance.

cs.CV

PathBench: A comprehensive comparison benchmark for pathology foundation models towards precision oncology

The emergence of pathology foundation models has revolutionized computational histopathology, enabling highly accurate, generalized whole-slide image analysis for improved cancer diagnosis, and prognosis assessment. While these models show remarkable potential across cancer diagnostics and prognostics, their clinical translation faces critical challenges including variability in optimal model across cancer types, potential data leakage in evaluation, and lack of standardized benchmarks. Without rigorous, unbiased evaluation, even the most advanced PFMs risk remaining confined to research settings, delaying their life-saving applications. Existing benchmarking efforts remain limited by narrow cancer-type focus, potential pretraining data overlaps, or incomplete task coverage. We present PathBench, the first comprehensive benchmark addressing these gaps through: multi-center in-hourse datasets spanning common cancers with rigorous leakage prevention, evaluation across the full clinical spectrum from diagnosis to prognosis, and an automated leaderboard system for continuous model assessment. Our framework incorporates large-scale data, enabling objective comparison of PFMs while reflecting real-world clinical complexity. All evaluation data comes from private medical providers, with strict exclusion of any pretraining usage to avoid data leakage risks. We have collected 15,888 WSIs from 8,549 patients across 10 hospitals, encompassing over 64 diagnosis and prognosis tasks. Currently, our evaluation of 19 PFMs shows that Virchow2 and H-Optimus-1 are the most effective models overall. This work provides researchers with a robust platform for model development and offers clinicians actionable insights into PFM performance across diverse clinical scenarios, ultimately accelerating the translation of these transformative technologies into routine pathology practice.

cs.CV

Federated attention consistent learning models for prostate cancer diagnosis and Gleason grading

Artificial intelligence (AI) holds significant promise in transforming medical imaging, enhancing diagnostics, and refining treatment strategies. However, the reliance on extensive multicenter datasets for training AI models poses challenges due to privacy concerns. Federated learning provides a solution by facilitating collaborative model training across multiple centers without sharing raw data. This study introduces a federated attention-consistent learning (FACL) framework to address challenges associated with large-scale pathological images and data heterogeneity. FACL enhances model generalization by maximizing attention consistency between local clients and the server model. To ensure privacy and validate robustness, we incorporated differential privacy by introducing noise during parameter transfer. We assessed the effectiveness of FACL in cancer diagnosis and Gleason grading tasks using 19,461 whole-slide images of prostate cancer from multiple centers. In the diagnosis task, FACL achieved an area under the curve (AUC) of 0.9718, outperforming seven centers with an average AUC of 0.9499 when categories are relatively balanced. For the Gleason grading task, FACL attained a Kappa score of 0.8463, surpassing the average Kappa score of 0.7379 from six centers. In conclusion, FACL offers a robust, accurate, and cost-effective AI training model for prostate cancer pathology while maintaining effective data safeguards.

cs.CV

Blind deblurring for microscopic pathology images using deep learning networks

Artificial Intelligence (AI)-powered pathology is a revolutionary step in the world of digital pathology and shows great promise to increase both diagnosis accuracy and efficiency. However, defocus and motion blur can obscure tissue or cell characteristics hence compromising AI algorithms'accuracy and robustness in analyzing the images. In this paper, we demonstrate a deep-learning-based approach that can alleviate the defocus and motion blur of a microscopic image and output a sharper and cleaner image with retrieved fine details without prior knowledge of the blur type, blur extent and pathological stain. In this approach, a deep learning classifier is first trained to identify the image blur type. Then, two encoder-decoder networks are trained and used alone or in combination to deblur the input image. It is an end-to-end approach and introduces no corrugated artifacts as traditional blind deconvolution methods do. We test our approach on different types of pathology specimens and demonstrate great performance on image blur correction and the subsequent improvement on the diagnosis outcome of AI algorithms.

eess.IV