Mixing plant for JUNO liquid scintillator: Design, construction, installation and commissioning

The most challenging part of building the Jiangmen Underground Neutrino Observatory (JUNO) is the production of 20 kilotons of ultra pure Liquid Scintillator (LS). This paper presents the design, construction, installation, and commissioning of the LS Mixing Plant, a core facility dedicated to blending the primary organic solvent (LAB) with essential functional solutes (PPO, bis-MSB, and BHT). The main purpose of the Mixing Plant is to prepare and purify the concentrated Master Solution (MS) to achieve a low radioactive contamination background. The amount of radioactive contaminants in the MS are lowered by approximately two orders of magnitude after acid and water extraction, followed by a multi-stage filtration procedure. The purified MS is mixed with LAB and then diluted into the LS for JUNO experiments. Commissioning results of the LS verify that the Mixing Plant achieved its design goal, delivering ultra pure LS that satisfies the stringent radiopurity requirements for neutrino physics.

physics.ins-det↗

OCSU: Optical Chemical Structure Understanding for Molecule-centric Scientific Discovery

Understanding the chemical structure from a graphical representation of a molecule is a challenging image caption task that would greatly benefit molecule-centric scientific discovery. Variations in molecular images and caption subtasks pose a significant challenge in both image representation learning and task modeling. Yet, existing methods only focus on a specific caption task that translates a molecular image into its graph structure, i.e., OCSR. In this paper, we propose the Optical Chemical Structure Understanding (OCSU) task, which extends low-level recognition to multilevel understanding and aims to translate chemical structure diagrams into readable strings for both machine and chemist. To facilitate the development of OCSU technology, we explore both OCSR-based and OCSR-free paradigms. We propose DoubleCheck to enhance OCSR performance via attentive feature enhancement for local ambiguous atoms. It can be cascaded with existing SMILES-based molecule understanding methods to achieve OCSU. Meanwhile, Mol-VL is a vision-language model end-to-end optimized for OCSU. We also construct Vis-CheBI20, the first large-scale OCSU dataset. Through comprehensive experiments, we demonstrate the proposed approaches excel at providing chemist-readable caption for chemical structure diagrams, which provide solid baselines for further research. Our code, model, and data are open-sourced at https://github.com/PharMolix/OCSU.

cs.CV↗

Calibration Strategy of the JUNO-TAO Experiment

The Taishan Antineutrino Observatory (JUNO-TAO, or TAO) is a satellite detector for the Jiangmen Underground Neutrino Observatory (JUNO). Located near the Taishan reactor, TAO independently measures the reactor's antineutrino energy spectrum with unprecedented energy resolution. To achieve this goal, energy response must be well calibrated. Using the Automated Calibration Unit (ACU) and the Cable Loop System (CLS) of TAO, multiple radioactive sources are deployed to various positions in the detector to perform a precise calibration of energy response. The non-linear energy response can be controlled within 0.6% with different energy points of these radioactive sources. It can be further improved by using $^{12}\rm B$ decay signals produced by cosmic muons. Through the energy non-uniformity calibration, residual non-uniformity is less than 0.2%. The energy resolution degradation and energy bias caused by the residual non-uniformity can be controlled within 0.05% and 0.3%, respectively. In addition, the stability of other detector parameters, such as the gain of each silicon photo-multiplier, can be monitored with a special ultraviolet LED calibration system.

physics.ins-det↗

Development of water extraction system for liquid scintillatorpurification of JUNO

The Jiangmen Underground Neutrino Observatory (JUNO) uses 20k tons of liquid scintillator (LS)to detect neutrinos. The content of radioactive substances in the liquid scintillator will affect theexperimental results. JUNO will use counter current water extraction to reduce the radioactive metalions inside the LS. In this article, The factors that affect the final water extraction like the partitioncoefficient and the factors that affect it, the optimal mass transfer droplet size, the flow rate ratio,theoretical stage and different working mode (LS as continuous phase or dispersed phase) have beenstudied. We built counter current extraction prototype in the laboratory and a pilot plant in Daya Bay.We not only study the factors above, but also get a lot of engineering experience that worth sharing.

physics.ins-det↗

A liquid scintillator for a neutrino Detector working at -50 degree

A liquid scintillator (LS) is developed for the Taishan Antineutrino Observatory (TAO), a ton-level neutrino detector to measure the reactor antineutrino spectrum with sub-percent energy resolution by adopting Silicon Photomultipliers (SiPMs) as photosensor. To reduce the dark noise of SiPMs to an acceptable level, the LS has to work at -50 degree or lower. A customized apparatus based on a charge-coupled device (CCD) is developed to study the transparency of the liquid samples in a cryostat. We find that the water content in LS results in transparency degradation at low temperature, which can be cured by bubbling dry nitrogen to remove water. Adding 0.05% ethanol as co-solvent cures the solubility decrease problem of the fluors PPO and bis-MSB at low temperature. Finally, a Gadoliniumdoped liquid scintillator (GdLS), with 0.1% Gd by weight, 2 g/L PPO, 1 mg/L bis-MSB, and 0.05% ethanol by weight in the solvent LAB, shows good transparency at -50 degree and also good light yield.

physics.ins-det↗

The replacement system of the JUNO liquid scintillator pilot experiment at Daya Bay

The Jiangmen Underground Neutrino Observatory (JUNO), a multi-purpose neutrino experiment, will use 20 kt liquid scintillator (LS). To achieve the physics goal of determining the neutrino mass ordering, 3$\%$ energy resolution at 1 MeV is required. This puts strict requirements on the LS light yield and the transparency. Four LS purification steps have been designed and mid-scale plants have been built at Daya Bay. To examine the performance of the purified LS and find the optimized LS composition, the purified LS was injected to the antineutrino detector 1 in the experimental hall 1 (EH1-AD1) of the Daya Bay neutrino experiment. To pump out the original gadolinium loaded LS and fill the new LS, a LS replacement system has been built in EH1 in 2017. By replacing the Gd-LS with purified water, then replacing the water with purified LS, the replacement system successfully achieved the designed goal. Subsequently, the fluorescence and the wavelength shifter were added to higher concentrations via the replacement system. The data taken at various LS compositions helped JUNO determine the final LS cocktail. Details of the design, the construction, and the operation of the replacement system are reported in this paper.

physics.ins-det↗

A sealed ceramic GEM-based neutron detector

The GEM-based neutron detector has flourished in the past decade. However almost all the GEM-based neutron detectors work in the flow-gas mode, and the long-term performances of the detectors may be unstable due to the dynamic changes of atmospheric pressure and ambient temperature. In this paper, a sealed ceramic GEM-based neutron detector was developed at China Spallation Neutron Source (CSNS) and its sensitive area was 100 mm * 100 mm. The characterizations of the detector were presented and discussed, which included the plateau curve, the neutron beam profile, the neutron wavelength spectrum, the spatial resolution (FWHM: 2.77 mm), the two-dimensional (2D) imaging ability, the neutron detection efficiency and the counting rate instability (Relative Standard Deviation (RSD): 0.7%). The results show that the detector has good performances in sealed mode, and it can be used for the measurement of the direct neutron beam at CSNS.

physics.ins-det↗

The fast light of CsI(Na) crystals

The responds of different common alkali halide crystals to alpha-rays and gamma-rays are tested in our research. It is found that only CsI(Na) crystals have significantly different waveforms between alpha and gamma scintillations, while others have not this phenomena. It is suggested that the fast light of CsI(Na) crystals arises from the recombination of free electrons with self-trapped holes of the host crystal CsI. Self-absorption limits the emission of fast light of CsI(Tl) and NaI(Tl) crystals.

physics.ins-det↗

Neutron-gamma discrimination of CsI(Na) crystals for dark matter searches

The luminescent properties of CsI(Na) crystals are studied in this report. By using a TDS3054C oscilloscope with a sampling frequency of 5 GS/s, we find out that nuclear recoil signals are dominated by very fast light pulse with a decay time of ~20 ns, while γ-ray signals have a decay time of ~600 ns. The wavelength of nuclear recoil and γ-ray signals are also different. The study of n/γ separation shows that the rejection factor can reach an order of 10-7 with signal efficiency more than 80% at an equivalent electron recoil energy of 20 keV or more. Such a property makes CsI(Na) an ideal candidate for dark matter searches.

physics.ins-det↗